Objectives: to establish on a national basis whether the diagnostic accuracy of carotid duplex justifies carotid surgery without preoperative angiography. Design: prospective national multicentre study with 10 participating university and county hospitals. Material and Methods: one hundred and thirty-four patients, aged 69 +/- 9 years, were subjected to routine carotid duplex ultrasonography and angiography. The influence of relevant factors on the relation between ultrasonographic and angiographic variables was evaluated using multiple regression analysis. The capacity of carotid ultrasonography to detect internal carotid artery (ICA) stenosis greater than or equal to80% was assessed by receiver operating characteristic analysis. Results: the correlation between peak systolic velocity in ICA (PSVICA) and the angiographic degree of stenosis was strong and significantly influenced only by the applied Doppler angle. Accordingly, the optimal PSVICA cutpoint values for the diagnosis of ICA stenosis greater than or equal to80% (ECST method) differed substantially (2.1 and 3.2 m/s) between the two considered angle ranges (0-49degrees and 50-62degrees), the ability to identify high grade ICA stenosis being significantly better at small Doppler angles (0-49degrees). Conclusion: ultrasonographic duplex technique identifies high grade ICA stenosis with a high degree of accuracy, which can be further improved by the application of small Doppler angles and the use of angle range specific PSVICA cut-off points.
引用
收藏
页码:510 / 518
页数:9
相关论文
共 50 条
  • [21] Duplex ultrasonography and carotid artery dissection
    Cucchiara, B
    Kasner, SE
    MAYO CLINIC PROCEEDINGS, 2000, 75 (06) : 658 - 659
  • [22] Comparison of transcranial Doppler ultrasound (TCD) and carotid duplex ultrasonography (CDUS) for detecting haemodynamically significant internal carotid artery (ICA) stenosis
    Niknam, Z.
    Zamani, B.
    EUROPEAN JOURNAL OF NEUROLOGY, 2008, 15 : 261 - 261
  • [23] Effect of contralateral disease on duplex measurements of internal carotid artery stenosis
    Ray, SA
    Lockhart, SJM
    Dourado, R
    Irvine, AT
    Burnand, KG
    BRITISH JOURNAL OF SURGERY, 2000, 87 (08) : 1057 - 1062
  • [24] The pitfalls of duplex scanning in bilateral distal stenosis of the internal carotid artery
    Migdalski, Arkadiusz
    Jawien, Arkadiusz
    ACTA ANGIOLOGICA, 2008, 14 (02): : 66 - 71
  • [25] The impact of different spectral Doppler criteria on the proportion of high-grade internal carotid artery stenosis in patients undergoing duplex scanning
    Logason, K
    Karacagil, S
    Ulus, AT
    Hårdemark, HG
    ANGIOLOGY, 2002, 53 (03) : 297 - 301
  • [26] Relationship between internal carotid artery stenosis grade and optic nerve sheath diameter measured by transorbital ultrasonography
    Komut, Erdal
    Murat, Muammer
    Buyuksireci, Mehmet
    Komut, Seval
    Kozaci, Nalan
    JOURNAL OF CLINICAL ULTRASOUND, 2021, 49 (07) : 724 - 730
  • [27] CONTRALATERAL OCCLUSION OF THE INTERNAL CAROTID ARTERY IN THE STUDY OF CAROTID STENOSIS USING DOPPLER ULTRASONOGRAPHY
    Gerediaga, G. D.
    Elizagaray, E.
    Canto-Morereira, N.
    Albuquerque, C.
    Branco, R.
    Beirao, I.
    Grande, T.
    REVISTA DE NEUROLOGIA, 2009, 48 (08) : 406 - 411
  • [28] Role of Carotid Ultrasonography Combined with Monocyte/HDL Ratio in Internal Carotid Artery Stenosis
    Bao, Min-qiang
    Chen, Yi-nong
    Jin, Ji-wei
    Gui, Dong-dong
    Wang, Jie
    Chen, Shuang-shuang
    Sheng, Xiao-ning
    Cheng, Zhang-long
    Wang, Yu
    CURRENT MEDICAL IMAGING, 2024, 20
  • [29] Accuracy of conventional plus transoral carotid duplex ultrasonography for diagnosis of pseudoocclusion of the internal carotid artery
    Fujimoto, S
    Toyocia, K
    Kishikawa, K
    Inoue, T
    Yasumod, K
    Ibayashi, S
    Okada, Y
    STROKE, 2005, 36 (02) : 483 - 483
  • [30] Duplex ultrasonography for the detection of vertebral artery stenosis A comparison with CT angiography
    Rozeman, Anouk D.
    Hund, Hajo
    Westein, Michel
    Wermer, Marieke J. H.
    Nijeholt, Geert J. Lycklama A.
    Boiten, Jelis
    Schimsheimer, Robert-Jan
    Algra, Ale
    BRAIN AND BEHAVIOR, 2017, 7 (08):