Amperometric Biosensor: Increased Sensitivity Using Enzyme Nanoparticles

被引:0
|
作者
Sharma, Shikha [1 ]
Shrivastav, Aditi [1 ]
Gupta, Nidhi [1 ]
Srivastava, Sudha [1 ]
机构
[1] Jaypee Inst Informat Technol, Dept Biotechnol, Noida 201307, India
关键词
GLUCOSE BIOSENSOR;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Here we present a comparative study of amperometric biosensor developed by using nanoparticles of Glucose oxidase enzyme-itself (GOx up) with that of enzyme immobilized on to gold nanoparticles (Au np-GOx). The biosensor developed by immobilizing the GOx np (45-70 nm in size) directly onto the Pt. electrode could detect glucose concentrations as low as 1 mM while the one with Au np-GOx (Au up 10-16 nm in size) showed a detection limit up to 5 mM only. Current response showed linearity up to 35 mM in both the cases. To the best of our knowledge the glucose biosensors prepared using various metal nanoparticles, Au, Ni, Ag (as reported in literature) showed a linear range from 2.7-30 mM glucose concentration. We are in the process of optimizing the immobilization methods and functionalization of the enzyme nanoparticles so as to have a wider temperature and pH stability of the biosensor. We feel the direct immobilization of enzyme nanoparticles, with proper choice of functionalization seems to be a promising strategy for biosensor development with higher sensitivities.
引用
收藏
页码:24 / 27
页数:4
相关论文
共 50 条
  • [41] Benzoquinone-mediated enzyme biosensor for amperometric determination of glucose
    Murthy, ASN
    Sharma, J
    PROCEEDINGS OF THE INDIAN ACADEMY OF SCIENCES-CHEMICAL SCIENCES, 1997, 109 (04): : 295 - 301
  • [42] Benzoquinone-mediated enzyme biosensor for amperometric determination of glucose
    A S N Murthy
    Jyotsna Sharma
    Proceedings of the Indian Academy of Sciences - Chemical Sciences, 1997, 109 (4) : 295 - 301
  • [43] Development of an amperometric enzyme electrode biosensor for fish freshness detection
    Ghosh, S.
    Sarker, D.
    Misra, T.N.
    Sensors and Actuators, B: Chemical, 1998, B53 (1-2): : 58 - 62
  • [44] Gold nanoparticles-mesoporous silica composite used as an enzyme immobilization matrix for amperometric glucose biosensor construction
    Bai, Yu
    Yang, Hua
    Yang, Weiwei
    Li, Yancai
    Sun, Changqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (01): : 179 - 186
  • [45] A novel amperometric biosensor for rapid detection of ethanol utilizing gold nanoparticles and enzyme coupled PVC reaction cell
    Hooda, Vinita
    Gahlaut, Anjum
    Hooda, Vikas
    ENVIRONMENTAL TECHNOLOGY, 2021, 42 (21) : 3318 - 3328
  • [46] An amperometric glucose biosensor with enhanced measurement stability and sensitivity using an artificially porous conductin polymer
    Ekanayake, E. M. I. Mala
    Preethichandra, D. M. G.
    Kaneto, Keiichi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (08) : 1621 - 1626
  • [47] Amperometric L-lactate biosensor based on gold nanoparticles
    Jena, Bikash Kumar
    Raj, C. Retna
    ELECTROANALYSIS, 2007, 19 (7-8) : 816 - 822
  • [48] A Numerical Simulation of Amperometric Biosensor Effect of Enzyme Loading and Stirring Strength on Biosensor's Performance
    Benyahia, A.
    Bacha, S.
    AFRICAN REVIEW OF PHYSICS, 2007, 1 : 6 - 7
  • [49] Amperometric enzyme biosensor for hydrogen peroxide via Ugi multicomponent reaction
    Camacho, Conrado
    Matias, Juan C.
    Garcia, Daniel
    Simpson, Benjamin K.
    Villalonga, Reynaldo
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (07) : 1655 - 1660
  • [50] A novel enzyme-free FI-amperometric glucose biosensor at Cu nanoparticles modified graphite pencil electrode
    Ayaz, Selen
    Karakaya, Serkan
    Emir, Gamze
    Dilgin, Didem Giray
    Dilgin, Yusuf
    MICROCHEMICAL JOURNAL, 2020, 154