Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots

被引:6
|
作者
Tran Thi Thao Nguyen [1 ,4 ]
Arimura, Hidetaka [2 ]
Asamura, Ryosuke [1 ]
Hirose, Taka-aki [1 ,3 ]
Ohga, Saiji [2 ]
Fukunaga, Jun-ichi [3 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Div Med Quantum Sci,Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[2] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Div Med Quantum Sci,Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[3] Kyushu Univ Hosp, Dept Med Technol, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[4] Japan Soc Promot Sci, Chiyoda Ku, 5-3-1 Kojimachi, Tokyo 1020083, Japan
基金
日本学术振兴会;
关键词
Prostate cancer; Cold spot; VMAT; IMRT; Probabilistic distribution; EXTERNAL-BEAM RADIOTHERAPY; SHAPE VARIATIONS; IMRT; CONFORMITY; GUIDELINES; ACCURACY; DELIVERY; INDEX;
D O I
10.1007/s12194-019-00502-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study compared dosimetric indices of volumetric-modulated arc therapy (VMAT) with intensity-modulated radiation therapy (IMRT) accounting for cold spots in prostate cancer plans. IMRT plans were retrospectively generated from 30 prostate cancer patients with ten cases for each risk group, who received VMAT plans. The mean, maximum, and minimum doses, and conformity and homogeneity indexes were evaluated for planning target volume (PTV) and the mean dose and V20-V70 for organs at risk (OAR) including the rectum, bladder, right and left femoral heads, and rectum overlapped with PTV (ROP) regions. The numbers and volume percentages of cold spots within PTVs and ROP regions were measured using in-house software. Three-dimensional probabilistic distributions of the probability and distributions of cold spots were generated using a centroid matching technique for visualization and analysis. There was a statistically better dose conformity in the PTV, rectum, and bladder dose-sparing in VMAT compared to that in the IMRT plans, whereas VMAT had statistically worse target dose homogeneity, and right and left femoral head dose-sparing than those of the IMRT plans. The average volume percentage of cold spots per PTV for the VMAT was 4.37 +/- 2.68%, which was smaller than the 5.72 +/- 1.84% observed for IMRT plans (P=0.007). The volume percentage of cold spots per ROP for the VMAT did not significantly differ from those for the IMRT plans. Compared with IMRT, the VMAT plans achieved better PTV dose conformity, OAR dose-sparing, and smaller cold spots in the treatment of prostate cancer.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 50 条
  • [21] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [22] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [23] Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels
    Onal, Cem
    ArsIan, Gungor
    Dolek, Yemliha
    Efe, Esma
    Medical Dosimetry, 2016, 41 (04) : 310 - 314
  • [24] Plan Robustness Study of Volumetric-Modulated Arc Therapy Vs. Intensity-Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S.
    Shen, J.
    Harrington, D.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W.
    Halyard, M.
    Schild, S.
    Ezzell, G.
    Bues, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3478 - 3478
  • [25] Comparative analysis of volumetric-modulated arc therapy and intensity-modulated radiotherapy for base of tongue cancer
    Nithya, L.
    Raj, N. Arunai Nambi
    Arulraj, Kumar
    Rathinamuthu, Sasikumar
    Pandey, Manish Bhushan
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (02) : 121 - 126
  • [26] Quality of treatment plans and accuracy of in vivo portal dosimetry in hybrid intensity-modulated radiation therapy and volumetric modulated arc therapy for prostate cancer
    Bedford, James L.
    Smyth, Gregory
    Hanson, Ian M.
    Tree, Alison C.
    Dearnaley, David P.
    Hansen, Vibeke N.
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 320 - 326
  • [27] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [28] Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma
    Yang, Hao
    Feng, Cong
    Cai, Bo-Ning
    Yang, Jun
    Liu, Hai-Xia
    Ma, Lin
    DISEASES OF THE ESOPHAGUS, 2017, 30 (02):
  • [29] Volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators
    Treutwein, Marius
    Hipp, Matthias
    Koelbl, Oliver
    Dobler, Barbara
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 307 - 314
  • [30] Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer
    Hall, William A.
    Fox, Timothy H.
    Jiang, Xiaojun
    Prabhu, Roshan S.
    Rossi, Peter J.
    Godette, Karen
    Jani, Ashesh B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (02) : 128 - 134