Assessing clot lysis strategies using a simplified mathematical model

被引:2
|
作者
Smye, SW
Berridge, D
Ouriel, K
Parkin, A
David, T
机构
[1] ST JAMES UNIV HOSP, DEPT VASC SURG, LEEDS LS9 7TF, W YORKSHIRE, ENGLAND
[2] UNIV ROCHESTER, SCH MED, DEPT SURG, ROCHESTER, NY USA
关键词
D O I
10.3109/03091909709031157
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper attempts to describe lysis of a clot by infusion of lytic agent using a simple geometrical approach, in which the rate of clot lysis is assumed proportional to the exposed surface of the clot and the concentration of lytic agent. Six simple realizations (a)-(f) of this basic model are developed which account for the dependence of clot lysis time on five different clot geometries. In all six cases the clot is initially described as a uniform cylinder which totally occludes a vessel. In model (a) lysis proceeds as an advancing front at the proximal face of the clot. In model (b) lysis proceeds radially outwards from the central axis of the vessel while in model (c) lysis occurs radially inwards from the surface adjacent the wall, of the cylinder. In models (d) and (e) it is assumed that the clot breaks into n uniform spherical and cylindrical fragments, respectively, while model (f) uses the spherical fragment model combined with a lytic agent concentration which decreases with time. The validity of the models was assessed using previously published data from 76 patients in whom lysis time and clot size were recorded. Least squares linear regression analysis based on the six model equations yielded highly significant correlation coefficients r(2) of 0.457, 0.412, 0.412, 0.495, 0.469, 0.663 for models (a)-(f), respectively. The results suggest that when a constant lytic agent concentration is assumed, no single geometry accounts for significantly more variation than any other, but that a combination of varying lytic agent concentration and clot geometry significantly influences clot lysis time and accounts for much of the observed variation.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [31] Enhanced clot microfragmentation and lysis using ultrasound and perfluorocarbon-filled polymer microbubbles
    Dhond, MR
    Dolan, C
    Nguyen, TT
    Pulido, G
    Bommer, W
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 488A - 489A
  • [32] Ultrasound-facilitated clot lysis using tPA-loaded echogenic liposomes
    Tiukinhoy-Laing, S
    Huang, SL
    Parikh, DS
    Martinez, J
    Vaidya, SS
    Holland, CK
    MacDonald, RC
    McPherson, DD
    CIRCULATION, 2005, 112 (17) : U696 - U696
  • [33] Successful clot lysis using low dose of streptokinase in 22 neonates with aortic thromboses
    Boo, NY
    Cheah, FC
    Rohana, J
    Yong, SC
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2001, 37 (05) : 479 - 482
  • [34] Assessment of pertussis vaccination strategies using a mathematical model of disease transmission
    Pesco, Pablo
    Bergero, Paula
    Fabricius, Gabriel
    Hozbor, Daniela
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2013, 111 (05): : 377 - U44
  • [35] STUDIES ON METHOD OF EUGLULIN CLOT LYSIS TIME USING ACID-TREATED EUGLOBULIN
    YASUKOUCHI, T
    YOSHIDA, S
    WATANABE, T
    FUJINE, M
    KOHN, S
    MORIOKA, T
    SAKURAMA, S
    NAKAGAWA, S
    ACTA HAEMATOLOGICA JAPONICA, 1978, 41 (03): : 553 - 558
  • [36] CAPILLARY BLOCKADE PRODUCED BY RAPID CLOT LYSIS IN AN EXPERIMENTAL RABBIT PULMONARY-EMBOLISM MODEL
    HOLDEN, RW
    BECKER, GJ
    MATTLER, LE
    SCHAUWECKER, DS
    MOCK, BH
    OFFEN, WW
    THROMBOSIS AND HAEMOSTASIS, 1985, 54 (01) : 106 - 106
  • [37] A SIMPLIFIED MATHEMATICAL-MODEL DESCRIBING THE ACTIVATION OF CARBON
    FRIEDRICH, S
    GELBIN, D
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1985, 19 (03) : 143 - 149
  • [38] A simplified mathematical model to predict PVC photodegradation in photobioreactors
    D'Aquino, C. A.
    Balmant, W.
    Ribeiro, R. L. L.
    Munaro, M.
    Vargas, J. V. C.
    Amico, S. C.
    POLYMER TESTING, 2012, 31 (05) : 638 - 644
  • [39] A SIMPLIFIED MATHEMATICAL-MODEL FOR AN ONBOARD MANEUVERING SIMULATOR
    BIANCARDI, CG
    SIMULATION, 1988, 51 (02) : 75 - 81
  • [40] SANDWICH TRANSDUCER, SIMPLIFIED MATHEMATICAL MODEL - 1.
    Dominguez, R.
    Ranz, C.
    1600, (29):