In situ mechanical testing of dry and hydrated breadcrumb in the environmental scanning electron microscope (ESEM)

被引:55
|
作者
Stokes, DJ [1 ]
Donald, AM [1 ]
机构
[1] Univ Cambridge, Cavendish Lab, Dept Phys, Cambridge CB3 0HE, England
基金
英国生物技术与生命科学研究理事会;
关键词
D O I
10.1023/A:1004720209547
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The environmental scanning electron microscope (ESEM) has the ability to image both dry and hydrated materials, without the need for a conductive coating, unlike conventional SEM. This presents a unique opportunity to explore the structure and dynamic mechanical characteristics of food systems, including those in a moist state. We have developed a technique in which quantitative stress-strain relationships can be obtained whilst allowing simultaneous imaging, by ESEM, of the mechanical response of a sample. The results of in situ compression tests on dry and hydrated wheat flour breadcrumbs are presented and discussed. It was found that a maximum in the critical fracture stress occurred at intermediate moisture content (similar to 16%). ESEM micrographs demonstrate the differences in mechanical behaviour at three different moisture contents (nominally dry, 16% and 30%). Our findings suggest that 'voids' in cell walls, along with discontinuities between starch granules and gluten in the crumb, play an important role in fracture initiation. Further evidence shows that voids may be bridged by 'struts' and 'strings' of matrix material, which may be factors in the control of fracture propagation. (C) 2000 Kluwer Academic Publishers.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [31] In situ study of the sintering of a lead phosphovanadate in an Environmental Scanning Electron Microscope
    Courtois, Eglantine
    Thollet, Gilbert
    Campayo, Lionel
    Le Gallet, Sophie
    Bidault, Olivier
    Bernard, Frederic
    SOLID STATE IONICS, 2011, 186 (01) : 53 - 58
  • [32] Examination of the transition of cultured neuronal cells from submerged to exposed using an environmental scanning electron microscope (ESEM)
    Uroukov, Ivan S.
    Patton, David
    MICRON, 2014, 56 : 1 - 7
  • [33] Microstructural Changes of Ni/YSZ Cermet under Repeated Redox Reaction in Environmental Scanning Electron Microscope (ESEM)
    Nakagawa, Y.
    Yashiro, K.
    Sato, K.
    Kawada, T.
    Mizusaki, J.
    SOLID OXIDE FUEL CELLS 10 (SOFC-X), PTS 1 AND 2, 2007, 7 (01): : 1373 - +
  • [34] X-ray microanalysis in the environmental scanning electron microscope (ESEM): Small size particles analysis limits
    Khouchaf, L
    Verstraete, J
    JOURNAL DE PHYSIQUE IV, 2002, 12 (PR6): : 341 - 346
  • [35] Mechanical scanning of the specmen in the scanning electron microscope
    Oho, E
    Miyamoto, M
    SCANNING, 2004, 26 (05) : 250 - 255
  • [36] Applications of environmental scanning electron microscopy (ESEM) in biomaterials field
    Manero, JM
    Gil, FJ
    Padrós, E
    Planell, JA
    MICROSCOPY RESEARCH AND TECHNIQUE, 2003, 61 (05) : 469 - 480
  • [37] In situ mechanical testing of fully hydrated carrots (Daucus carota) in the environmental SEM
    Thiel, BL
    Donald, AM
    ANNALS OF BOTANY, 1998, 82 (06) : 727 - 733
  • [38] Applications of Environmental Scanning Electron Microscopy (ESEM) in botanical research
    Sorbo, Sergio
    Basile, Adriana
    Cobianchi, Rosa Castaldo
    PLANT BIOSYSTEMS, 2008, 142 (02): : 355 - 359
  • [39] In situ tensile testing of individual Co nanowires inside a scanning electron microscope
    Zhang, Dongfeng
    Breguet, Jean-Marc
    Clavel, Reymond
    Philippe, Laetitia
    Utke, Ivo
    Michler, Johann
    NANOTECHNOLOGY, 2009, 20 (36)
  • [40] In-situ fatigue in an environmental scanning electron microscope -: Potential and current limitations
    Biallas, G.
    Maier, H. J.
    INTERNATIONAL JOURNAL OF FATIGUE, 2007, 29 (08) : 1413 - 1425