Template based Attenuation Correction for PET in MR-PET Scanners

被引:0
|
作者
Kops, Elena Rota [1 ]
Herzog, Hans [1 ]
机构
[1] Forschungszentrum Julich, Julich, Germany
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work investigates a template based procedure for attenuation correction (TBA) of PET scans acquired in future hybrid MR-PET scanners which will not offer a measured attenuation correction. A previous report of our group described a method (TBA-SPM) how individual attenuation maps can be obtained from an attenuation template which is spatially normalized to the SPM2 standard brain shape. Attenuation maps of females and males obtained from PET transmission scans were used as input for this template. The present study replaces the template referring to SPM2 by a female and a male attenuation template (fAT and mAT), each based on four measured attenuation images (TBA-f&m). The corresponding T1-MR templates (fMR and mMR) were also available. Thus, possible morphological gender-related differences, not considered when the standardized SPM2 (1)brain shape is used, may be taken into account. To examine this approach PET scans of 15 female and 15 male subjects of an ongoing study were attenuation corrected using the templates fAT and mAT. For this purpose and depending on the subject's gender the fMR or mMR templates were warped onto the individual MR image. The resulting warping matrix was applied to fAT or mAT, respectively. The individualized attenuation maps were used to reconstruct the PET emission data. These were compared to PET images attenuation corrected with the conventional PET based transmission data (PBA). While the relative differences between PBA and TBA-f&m reconstructed images averaged over each group and all regions of interest were 0.57% +/- 3.76% for females and -0.59% +/- 3-56% for males, the corresponding values obtained with the TBA-SPM method showed an overestimation with similar standard deviations (2.39% +/- 3.76% for females and 2.42% +/- 3.37% for males). In conclusion, the alter-native gender-related template method TBA-f&m gives acceptable results with no significant differences between the genders.
引用
收藏
页码:3061 / 3064
页数:4
相关论文
共 50 条
  • [41] Examination of the absorption correction for the 3D MR-PET Imaging
    Yamada, M.
    Yamagishi, M.
    Hirano, M.
    Watanabe, S.
    Kikuta, D.
    Ito, K.
    Seto, A.
    Imabayashi, E.
    Kuji, I.
    Ito, K.
    Matsuda, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S478 - S479
  • [42] Automatic MR-PET registration algorithm
    Phillips, PJ
    Vardi, Y
    Dunn, SM
    Buchsbaum, MS
    Spiegel-Cohen, JL
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1998, 9 (01) : 46 - 50
  • [43] Clinical evaluation of MLAA for MR-PET
    Bal, Girish
    Kehren, Frank
    Michel, Christian
    Watson, Charles
    Manthey, Dieter
    Nuyts, Johan
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [44] PET Image Reconstruction using Joint MR-PET Dictionary
    Sudarshan, Viswanath P.
    Chen, Zhaolin
    Egan, Gary
    Awate, Suyash P.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [45] The optimization of the absorption correction for the 3D MR-PET Imaging
    Yamada, M.
    Yamagishi, M.
    Hirano, M.
    Kikuta, D.
    Hirai, M.
    Kawamura, Y.
    Ohnuki, K.
    Haruta, H.
    Takizawa, O.
    Shimano, Y.
    Ito, K.
    Seto, A.
    Imabayashi, E.
    Kuji, I.
    Matsuda, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S487 - S487
  • [46] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Jan Vontobel
    Riccardo Liga
    Mathias Possner
    Olivier F. Clerc
    Fran Mikulicic
    Patrick Veit-Haibach
    Edwin E. G. W. ter Voert
    Tobias A. Fuchs
    Julia Stehli
    Aju P. Pazhenkottil
    Dominik C. Benz
    Christoph Gräni
    Oliver Gaemperli
    Bernhard Herzog
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1574 - 1580
  • [47] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [48] Image artifacts from MR-based attenuation correction in dedicated PET/MR breast coil for PET/MR mammography
    Ihnho Cho
    Eunjung Kong
    Kyunga Chun
    EJNMMI Physics, 2 (Suppl 1)
  • [49] Zero Echo Time MR Attenuation Correction Method on the GE SIGNA PET/MR: Comparison with CT Based Attenuation Correction in Dynamic PET Brain imaging
    Firouzian, A.
    Delso, G.
    McCutcheon, R.
    Nour, M.
    Howes, O.
    Hallett, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S288 - S289
  • [50] Evaluation of Segmentation Based Attenuation Correction Methods for PET/MR in the Thorax
    Ai, H.
    Pan, T.
    MEDICAL PHYSICS, 2013, 40 (06)