End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions

被引:58
|
作者
Bikker, Ido G. [1 ]
van Bommel, Jasper [1 ]
Miranda, Dinis Reis [1 ]
Bakker, Jan [1 ]
Gommers, Diederik [1 ]
机构
[1] Erasmus MC, Dept Intens Care Med, NL-3015 CE Rotterdam, Netherlands
来源
CRITICAL CARE | 2008年 / 12卷 / 06期
关键词
D O I
10.1186/cc7125
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Functional residual capacity (FRC) reference values are obtained from spontaneous breathing patients, and are measured in the sitting or standing position. During mechanical ventilation FRC is determined by the level of positive end-expiratory pressure (PEEP), and it is therefore better to speak of end-expiratory lung volume. Application of higher levels of PEEP leads to increased end-expiratory lung volume as a result of recruitment or further distention of already ventilated alveoli. The aim of this study was to measure end-expiratory lung volume in mechanically ventilated intensive care unit (ICU) patients with different types of lung pathology at different PEEP levels, and to compare them with predicted sitting FRC values, arterial oxygenation, and compliance values. Methods End-expiratory lung volume measurements were performed at PEEP levels reduced sequentially (15, 10 and then 5 cmH(2)O) in 45 mechanically ventilated patients divided into three groups according to pulmonary condition: normal lungs (group N), primary lung disorder (group P), and secondary lung disorder (group S). Results In all three groups, end-expiratory lung volume decreased significantly (P < 0.001) while PEEP decreased from 15 to 5 cmH(2)O, whereas the ratio of arterial oxygen tension to inspired oxygen fraction did not change. At 5 cmH(2)O PEEP, end-expiratory lung volume was 31, 20, and 17 ml/kg predicted body weight in groups N, P, and S, respectively. These measured values were only 66%, 42%, and 34% of the predicted sitting FRC. A correlation between change in end-expiratory lung volume and change in dynamic compliance was found in group S (P < 0.001; R-2 = 0.52), but not in the other groups. Conclusions End-expiratory lung volume measured at 5 cmH(2)O PEEP was markedly lower than predicted sitting FRC values in all groups. Only in patients with secondary lung disorders were PEEP-induced changes in end-expiratory lung volume the result of derecruitment. In combination with compliance, end-expiratory lung volume can provide additional information to optimize the ventilator settings.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Effect of tidal volume and positive end-expiratory pressure on expiratory time constants in experimental lung injury
    Henderson, William R.
    Dominelli, Paolo B.
    Molgat-Seon, Yannick
    Lipson, Rachel
    Griesdale, Donald E. G.
    Sekhon, Mypinder
    Ayas, Najib
    Sheel, A. William
    PHYSIOLOGICAL REPORTS, 2016, 4 (05): : 1 - 11
  • [32] THE CARDIOVASCULAR EFFECTS OF MECHANICAL VENTILATION AND POSITIVE END-EXPIRATORY PRESSURE
    LUCE, JM
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 252 (06): : 807 - 811
  • [33] CARDIOVASCULAR EFFECTS OF MECHANICAL VENTILATION AND POSITIVE END-EXPIRATORY PRESSURE
    LHOMMEDIEU, CS
    FARRELL, SL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (15): : 2195 - 2196
  • [34] VENTILATION WITH END-EXPIRATORY PRESSURE IN ACUTE LUNG-DISEASE
    FALKE, KJ
    LAVER, MB
    KUMAR, A
    PONTOPPI.H
    LEITH, DE
    GEFFIN, B
    JOURNAL OF CLINICAL INVESTIGATION, 1972, 51 (09): : 2315 - +
  • [35] INTRAOCULAR-PRESSURE DURING MECHANICAL VENTILATION WITH DIFFERENT LEVELS OF POSITIVE END-EXPIRATORY PRESSURE
    TEBA, L
    VITI, A
    BANKS, DE
    FONS, A
    BARBERA, M
    HSHIEH, PB
    CRITICAL CARE MEDICINE, 1993, 21 (06) : 867 - 870
  • [36] Why high levels of positive end-expiratory pressure are required to maintain a stable end-expiratory lung volume in morbidly obese subjects
    Koutsoukou, A.
    Koulouris, N. G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (06)
  • [37] Effects of prone position and positive end-expiratory pressure on lung perfusion and ventilation
    Richard, Jean-Christophe
    Bregeon, Fabienne
    Costes, Nicolas
    Bars, Didier L. E.
    Tourvieille, Christian
    Lavenne, Franck
    Janier, Marc
    Bourdin, Gael
    Gimenez, Gerard
    Guerin, Claude
    CRITICAL CARE MEDICINE, 2008, 36 (08) : 2373 - 2380
  • [38] Low measured auto-positive end-expiratory pressure during mechanical ventilation of patients with severe asthma: Hidden auto-positive end-expiratory pressure
    Leatherman, J
    Ravenscraft, SA
    CRITICAL CARE MEDICINE, 1996, 24 (03) : 541 - 546
  • [39] Effect of tidal volume and positive end-expiratory pressure on lung hysteresis of healthy piglets
    DT Andreis
    M Milesi
    P Pugni
    F Nicosia
    GE lapichino
    M Monti
    B Comini
    E Votta
    A Protti
    L Gattinoni
    Critical Care, 18 (Suppl 1):
  • [40] Positive End-expiratory Pressure and Mechanical Power
    Collino, Francesca
    Rapetti, Francesca
    Vasques, Francesco
    Maiolo, Giorgia
    Tonetti, Tommaso
    Romitti, Federica
    Niewenhuys, Julia
    Behnemann, Tim
    Camporota, Luigi
    Hahn, Guenter
    Reupke, Verena
    Holke, Karin
    Herrmann, Peter
    Duscio, Eleonora
    Cipulli, Francesco
    Moerer, Onnen
    Marini, John J.
    Quintel, Michael
    Gattinoni, Luciano
    ANESTHESIOLOGY, 2019, 130 (01) : 119 - 130