Empirical Evaluation of Cross-Site Reproducibility in Radiomic Features for Characterizing Prostate MRI

被引:14
|
作者
Chirra, Prathyush [1 ]
Leo, Patrick [1 ]
Yim, Michael [2 ]
Bloch, B. Nicolas [3 ]
Rastinehad, Ardeshir R. [4 ]
Purysko, Andrei [5 ]
Rosen, Mark [6 ]
Madabhushi, Anant [1 ]
Viswanath, Satish [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Northeast Ohio Med Univ, Coll Med, Rootstown, OH USA
[3] Boston Univ, Sch Med, Dept Radiol, Boston, MA 02118 USA
[4] Icahn Sch Med Mt Sinai, Dept Urol, New York, NY 10029 USA
[5] Cleveland Clin, Dept Radiol, Cleveland, OH 44106 USA
[6] Hosp Univ Penn, Dept Radiol, 3400 Spruce St, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
radiomics; reproducibility; multi-site; MRI; prostate; feature analysis; stability; variance;
D O I
10.1117/12.2293992
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The recent advent of radiomics has enabled the development of prognostic and predictive tools which use routine imaging, but a key question that still remains is how reproducible these features may be across multiple sites and scanners. This is especially relevant in the context of MRI data, where signal intensity values lack tissue specific, quantitative meaning, as well as being dependent on acquisition parameters (magnetic field strength, image resolution, type of receiver coil). In this paper we present the first empirical study of the reproducibility of 5 different radiomic feature families in a multi-site setting; specifically, for characterizing prostate MRI appearance. Our cohort comprised 147 patient T2w MRI datasets from 4 different sites, all of which were first pre-processed to correct acquisition-related for artifacts such as bias field, differing voxel resolutions, as well as intensity drift (non-standardness). 406 3D voxel wise radiomic features were extracted and evaluated in a cross-site setting to determine how reproducible they were within a relatively homogeneous non-tumor tissue region; using 2 different measures of reproducibility: Multivariate Coefficient of Variation and Instability Score. Our results demonstrated that Haralick features were most reproducible between all 4 sites. By comparison, Laws features were among the least reproducible between sites, as well as performing highly variably across their entire parameter space. Similarly, the Gabor feature family demonstrated good cross-site reproducibility, but for certain parameter combinations alone. These trends indicate that despite extensive pre-processing, only a subset of radiomic features and associated parameters may be reproducible enough for use within radiomics-based machine learning classifier schemes.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Garnering Grantee Buy-In on a National Cross-Site Evaluation: The Case of ConnectHIV
    Rogers, Susan J.
    Ahmed, Marie
    Hamdallah, Myriam
    Little, Stacey
    AMERICAN JOURNAL OF EVALUATION, 2010, 31 (04) : 447 - 462
  • [32] The cost of HIV medication adherence support interventions: Results of a cross-site evaluation
    Schackman, BR
    Finkelstein, R
    Neukermans, CP
    Lewis, L
    Eldred, L
    AIDS CARE-PSYCHOLOGICAL AND SOCIO-MEDICAL ASPECTS OF AIDS/HIV, 2005, 17 (08): : 927 - 937
  • [33] Selected Findings from the Cross-Site Evaluation of the Federal Healthy Start Program
    Drayton, Vonna Lou Caleb
    Walker, Deborah Klein
    Ball, Sarah W.
    Donahue, Sara M. A.
    Fink, Rebecca V.
    MATERNAL AND CHILD HEALTH JOURNAL, 2015, 19 (06) : 1292 - 1305
  • [34] Development and implementation of the cross-site evaluation of the CDC/HRSA Corrections Demonstration Project
    Arriola, KRJ
    Kennedy, SS
    Coltharp, JC
    Braithwaite, RL
    Hammett, TM
    Tinsley, MJ
    AIDS EDUCATION AND PREVENTION, 2002, 14 (03) : 107 - 118
  • [35] Selected Findings from the Cross-Site Evaluation of the Federal Healthy Start Program
    Vonna Lou Caleb Drayton
    Deborah Klein Walker
    Sarah W. Ball
    Sara M. A. Donahue
    Rebecca V. Fink
    Maternal and Child Health Journal, 2015, 19 : 1292 - 1305
  • [36] CROSS-SITE REPRODUCIBILITY OF CORTICAL AND TRABECULAR BONE DENSITY AND MICRO-ARCHITECTURE MEASUREMENTS BY HR-PQCT
    Burghardt, A. J.
    Hermannsson, B.
    Pialat, J.
    Boutroy, S.
    Burrows, M.
    Liu, D.
    Patsch, J.
    Valentinitsch, A.
    Manoharan, R.
    Mckay, H.
    Boyd, S. K.
    Bouxsein, M. L.
    Majumdar, S.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : 45 - 46
  • [37] Consistent connectome landscape mining for cross-site brain disease identification using functional MRI
    Wang, Mingliang
    Zhang, Daoqiang
    Huang, Jiashuang
    Liu, Mingxia
    Liu, Qingshan
    MEDICAL IMAGE ANALYSIS, 2022, 82
  • [38] CONDITIONAL DOMAIN ADVERSARIAL TRANSFER FOR ROBUST CROSS-SITE ADHD CLASSIFICATION USING FUNCTIONAL MRI
    Huang, Ya-Lin
    Hsieh, Wan-Ting
    Yang, Hao-Chun
    Lee, Chi-Chun
    2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 1190 - 1194
  • [39] Multiple Kernel Learning applied to the prediction of prostate cancer recurrence from MRI radiomic features
    Marin-Castrillon, Diana M.
    Fontaine, Pierre
    Gnep, Khemara
    de Crevoisier, Renaud
    Diaz, Gloria M.
    Acosta, Oscar
    2019 IEEE 19TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2019, : 984 - 988
  • [40] Preoperative Evaluation of Myxofibrosarcoma: Prognostic Value and Reproducibility of Different Features on MRI
    Muehlhofer, Heinrich
    Gersing, Alexandra
    Pfeiffer, Daniela
    Woertler, Klaus
    Lenze, Ulrich
    Lenze, Florian
    Lallinger, Vincent
    Haller, Bernhard
    Burgkart, Rainer
    Von Eisenhart-Rothe, Rudiger
    Knebel, Carolin
    ANTICANCER RESEARCH, 2020, 40 (10) : 5793 - 5800