Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography

被引:54
|
作者
Yu, Honglian [1 ]
Merib, Josias [1 ]
Anderson, Jared L. [1 ]
机构
[1] Iowa State Univ, Dept Chem, 1605 Gilman Hall, Ames, IA 50011 USA
基金
美国国家科学基金会;
关键词
Polymeric ionic liquids; Solid-phase microextraction; High-performance liquid chromatography; Pharmaceutical drugs; Phenolics; Pesticides; OF-THE-ART; WATER SAMPLES; FIBER; HEADSPACE; EXTRACTION; MONOLITH;
D O I
10.1016/j.chroma.2016.02.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)(2)C-12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 mu g L-1 for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 21
页数:12
相关论文
共 50 条
  • [41] Determination of Norfloxacin and Enrofloxacin by Solid-Phase Microextraction/High-Performance Liquid Chromatography
    Kumar, Ashwini
    Dhingra, Gaurav
    Malik, Ashok Kumar
    Tewary, Dhananjay K.
    JOURNAL OF AOAC INTERNATIONAL, 2008, 91 (06) : 1339 - 1343
  • [42] Determination of delorazepam in urine by solid-phase microextraction coupled to high performance liquid chromatography
    Aresta, A
    Monaci, L
    Zambonin, CG
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (05) : 965 - 972
  • [43] Determination of ethanol in ionic liquids using headspace solid-phase microextraction–gas chromatography
    Fei Zhao
    Thehazhnan K. Ponnaiyan
    Christa M. Graham
    Constance A. Schall
    Sasidhar Varanasi
    Jared L. Anderson
    Analytical and Bioanalytical Chemistry, 2008, 392 : 1271 - 1275
  • [44] Development of a functionalized polymeric ionic liquid monolith for solid-phase microextraction of polar endocrine disrupting chemicals in aqueous samples coupled to high-performance liquid chromatography
    Juanjuan Feng
    Min Sun
    Yanan Bu
    Chuannan Luo
    Analytical and Bioanalytical Chemistry, 2015, 407 : 7025 - 7035
  • [45] Development of a functionalized polymeric ionic liquid monolith for solid-phase microextraction of polar endocrine disrupting chemicals in aqueous samples coupled to high-performance liquid chromatography
    Feng, Juanjuan
    Sun, Min
    Bu, Yanan
    Luo, Chuannan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (23) : 7025 - 7035
  • [46] Multiple monolithic fiber solid-phase microextraction based on a polymeric ionic liquid with high-performance liquid chromatography for the determination of steroid sex hormones in water and urine
    Liao, Keren
    Mei, Meng
    Li, Haonan
    Huang, Xiaojia
    Wu, Cuiqin
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (03) : 566 - 575
  • [47] Electropolymerized Pyrrole-Based Conductive Polymeric Ionic Liquids and Their Application for Solid-Phase Microextraction
    Devasurendra, Amila M.
    Zhang, Cheng
    Young, Joshua A.
    Tillekeratne, L. M. Viranga
    Anderson, Jared L.
    Kirchhoff, Jon R.
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (29) : 24955 - 24963
  • [48] Role of counteranions in polymeric ionic liquid-based solid-phase microextraction coatings for the selective extraction of polar compounds
    Meng, Yunjing
    Pino, Veronica
    Anderson, Jared L.
    ANALYTICA CHIMICA ACTA, 2011, 687 (02) : 141 - 149
  • [49] Ionic liquids-based crosslinked copolymer sorbents for headspace solid-phase microextraction of polar alcohols
    Feng, Juanjuan
    Sun, Min
    Wang, Xusheng
    Liu, Xia
    Jiang, Shengxiang
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1245 : 32 - 38
  • [50] Sorbent coatings for solid-phase microextraction targeted towards the analysis of death-related polar analytes coupled to comprehensive two-dimensional gas chromatography: Comparison of zwitterionic polymeric ionic liquids versus commercial coatings
    Carrico, Iris R.
    Marques, Jessica
    Trujillo-Rodriguez, Maria J.
    Anderson, Jared L.
    Rocha, Silvia M.
    MICROCHEMICAL JOURNAL, 2020, 158