Ultraviolet spectrophotometry as an index parameter for estimating the biochemical oxygen demand of domestic wastewater

被引:16
|
作者
Nataraja, M.
Qin, Y.
Seagren, E. A. [1 ]
机构
[1] Univ Maryland, Dept Civil & Environm Engn, College Pk, MD 20742 USA
[2] Cadmus Grp Inc, Arlington, VA 22209 USA
[3] Howard Cty Dept Planning & Zoning, Ellicott City, MD 21043 USA
关键词
BOD; UV absorbance; wastewater; prediction; index parameter;
D O I
10.1080/09593332708618691
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The relationship between ultraviolet absorbance at 280 nm (UV280) and the 5-day Biochemical Oxygen Demand (BOD5) test was evaluated using wastewater samples collected during March - December 1998 from the Fort Meade wastewater treatment plant (Maryland, U.S.A.). Three types of samples were collected: raw influent wastewater, primary effluent, and the effluent from the nitrification settling basin. A regression of BOD5 on UV. was obtained using half of the data, with the other half of the data used to test application of the equation. The presence of NO2-, and NO2-, did not interfere with the BOD5/UV relationship. However, the relative fraction of organic compounds that absorb at UV280 and are biodegradable did appear to decrease across the treatment plant, thereby reducing the strength of the association between BOD5 and UV280 further along the treatment train. Interestingly, the exclusion of solids > 1 mu m from the BOD, test did not strengthen the association between BOD5 and UV280 These results suggest that simple UV absorbance measurements may be a useful analytical tool for wastewater treatment personnel, allowing them to quickly monitor for changes in the BOD5 during the treatment process and to quickly estimate the BOD5 when determining what dilutions to use in the standard BOD5 test. However, such relationships are likely to be wastewater and treatment plant specific and variable with time and treatment.
引用
收藏
页码:789 / 800
页数:12
相关论文
共 50 条
  • [31] Optimization of the Chemical Oxygen Demand Removal from the Rural Domestic Wastewater using Taguchi Experimental Design Method
    Khairalla, Ahmed M. Osman
    Lu Xiwu
    PROCEEDINGS OF THE 2015 INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS, 2015, 40 : 1287 - 1292
  • [32] The Use of Biocatalyst Electrolysis to Decrease Total Suspended Solid (TSS) and Chemical Oxygen Demand (COD) Domestic Wastewater
    Purwono
    Oktiawan, Wiharyanto
    Hardiyanti, Nurandani
    ADVANCED SCIENCE LETTERS, 2017, 23 (03) : 2605 - 2607
  • [33] A novel BOD sensor immobilized active sludge bacteria for rapid determination of biochemical oxygen demand in industrial wastewater
    Lei, Hu
    Yi, Li
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 382 - 384
  • [34] Changes in the biochemical oxygen demand procedure in the 21st edition of Standard Methods for the Examination of Water and Wastewater
    Young, JC
    Clesceri, LS
    Kamhawy, SM
    WATER ENVIRONMENT RESEARCH, 2005, 77 (04) : 404 - 410
  • [35] The effect of hydrogen peroxide on the biochemical oxygen demand (BOD) values measured during ionizing radiation treatment of wastewater
    Bezsenyi, Aniko
    Sagi, Gyuri
    Mako, Magdolna
    Wojnarovits, Laszlo
    Takacs, Erzsebet
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [36] Changes in the biochemical oxygen demand procedure in the 21st edition of Standard Methods for the Examination of Water and Wastewater
    Albertson, Orris E.
    WATER ENVIRONMENT RESEARCH, 2007, 79 (04) : 453 - 455
  • [37] Novel techniques to determine dilution ratios of raw wastewater and wastewater treatment plant effluent in the 5-day biochemical oxygen demand test
    Ryu, Hong-Duck
    Park, Ji-Hyoung
    Kim, Yong Seok
    CHEMOSPHERE, 2022, 286
  • [38] Online biochemical oxygen demand monitoring for wastewater process control - Full-scale studies at Los Angeles Glendale Wastewater Plant, California
    Iranpour, Reza
    Zermeno, Miguel
    WATER ENVIRONMENT RESEARCH, 2008, 80 (04) : 298 - 307
  • [39] Partial Least Squares Regression Calibration of an Ultraviolet-Visible Spectrophotometer for Measurements of Chemical Oxygen Demand in Dye Wastewater
    Mai, W.
    Zhang, J. -F.
    Zhao, X. -M.
    Li, Z.
    Xu, Z. -W.
    JOURNAL OF APPLIED SPECTROSCOPY, 2017, 84 (05) : 804 - 810
  • [40] Partial Least Squares Regression Calibration of an Ultraviolet-Visible Spectrophotometer for Measurements of Chemical Oxygen Demand in Dye Wastewater
    W. Mai
    J.-F. Zhang
    X.-M. Zhao
    Z. Li
    Z.-W. Xu
    Journal of Applied Spectroscopy, 2017, 84 : 804 - 810