First-in-human experience with the Medtronic CoreValve Evolut R

被引:60
|
作者
Piazza, Nicolo [1 ]
Martucci, Giuseppe [1 ]
Lachapelle, Kevin [2 ]
de Varennes, Benoit [2 ]
Bilodeau, Luc [1 ]
Buithieu, Jean [1 ]
Mylotte, Darren [1 ]
机构
[1] McGill Univ, Dept Intervent Cardiol, Ctr Hlth, Montreal, PQ H3A 1A1, Canada
[2] McGill Univ, Ctr Hlth, Montreal, PQ H3A 1A1, Canada
关键词
AORTIC-VALVE IMPLANTATION;
D O I
10.4244/EIJV9I11A215
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The CoreValve Evolut R with EnVeo R delivery catheter is a novel transcatheter heart valve (THY) system with enhanced features that have the potential to improve the safety of transcatheter aortic valve implantation (TAVI). The newly designed delivery catheter is 14 Fr-equivalent and thus expands the option of transfemoral TAVI to a greater proportion of patients. Most importantly, the EnVeo R delivery catheter allows the valve to be recaptured and repositioned during deployment, thus minimising the consequences of THY malposition. Furthermore, the nitinol frame of the CoreValve Evolut R has been redesigned for superior interaction, consistent radial force and optimised cover index across the sizing range, and conformability with the native annulus, thereby hypothetically reducing stress on the left bundle branch. Although large series with long-term follow-up are required to demonstrate the safety and efficacy of this device, we present the first human experience with the Evolut R system.
引用
收藏
页码:1260 / 1263
页数:4
相关论文
共 50 条
  • [21] Conduction disorders using the Evolut R prosthesis compared with the CoreValve: has anything changed?
    Perrin, Nils
    Perrin, Tilman
    Hachulla, Anne-Lise
    Frei, Angela
    Mueller, Hajo
    Roffi, Marco
    Cikirikcioglu, Mustafa
    Ellenberger, Christoph
    Licker, Marc-Joseph
    Burri, Haran
    Noble, Stephane
    OPEN HEART, 2018, 5 (01):
  • [22] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R
    Hidehiro Kaneko
    Frank Hoelschermann
    Martin Seifert
    Grit Tambor
    Maki Okamoto
    Viviane Moeller
    Michael Neuss
    Christian Butter
    Heart and Vessels, 2019, 34 : 360 - 367
  • [23] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R
    Kaneko, Hidehiro
    Hoelschermann, Frank
    Seifert, Martin
    Tambor, Grit
    Okamoto, Maki
    Moeller, Viviane
    Neuss, Michael
    Butter, Christian
    HEART AND VESSELS, 2019, 34 (02) : 360 - 367
  • [24] First-in-human experience with Aortix intraaortic pump
    Vora, Amit N.
    Schuyler Jones, William
    DeVore, Adam D.
    Ebner, Adrian
    Clifton, William
    Patel, Manesh R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (03) : 428 - 433
  • [25] Transcathether aortic valve implantation with the new repositionable self-expandable Medtronic Evolut R vs. CoreValve system: evidence on the benefit of a meta-analytical approach
    Kowalewski, Mariusz
    Gozdek, Miroslaw
    Raffa, Giuseppe Maria
    Slomka, Artur
    Zielinski, Kamil
    Kubica, Jacek
    Anisimowicz, Lech
    Kowalewski, Janusz
    Landes, Uri
    Kornowski, Ran
    Lorusso, Roberto
    Suwalski, Piotr
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (04) : 226 - 236
  • [26] First experience with the 34 mm self-expanding Evolut R in a multicentre registry
    Harnath, Axel
    Gomes, Bruna
    Herwig, Volker
    Gatto, Fernando
    Watremez, Stephan
    Katus, Hugo A.
    Bekeredjian, Raffi
    EUROINTERVENTION, 2018, 14 (03) : 298 - 300
  • [27] Comparative Matched Outcome of Evolut-R vs CoreValve Transcatheter Aortic Valve Implantation
    Landes, Uri
    Bental, Tamir
    Barsheshet, Alon
    Assali, Abid
    Assa, Hana Vaknin
    Levi, Amos
    Orvin, Katia
    Kornowski, Ran
    JOURNAL OF INVASIVE CARDIOLOGY, 2017, 29 (02): : 69 - 74
  • [28] Valve-In-Valve With The New Recapturable CoreValve Evolut R™ For Degenerated Small Aortic Bioprostheses
    Fabbiocchi, Franco
    Olivares, Paolo
    Muratori, Manuela
    Salvi, Luca
    Alamanni, Francesco
    Bartorelli, Antonio L.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B259 - B260
  • [29] Cost Utility of Transcatheter Aortic Valve Replacement: Sapien 3 Versus CoreValve Evolut R
    Posawatz, David
    Bloom, Joshua
    Massed, Alison
    Chatterjee, Abhishek
    Resor, Charles
    Zhan, Yong
    Weintraub, Andrew
    Kawabori, Masashi
    ASAIO JOURNAL, 2023, 69 (05) : 475 - 482
  • [30] Performance of the CoreValve Evolut R and PRO in Severely Calcified Anatomy: A Propensity Score Matched Analysis
    Piayda, Kerstin
    Hellhammer, Katharina
    Veulemans, Verena
    Afzal, Shazia
    Heidari, Houtan
    Wimmer, Anna Christina
    Al Juburi, Maryam
    Antoch, Gerald
    Kelm, Malte
    Zeus, Tobias
    HEART LUNG AND CIRCULATION, 2020, 29 (12): : 1847 - 1855