The geometric factor of high energy protons detector on FY-3 satellite

被引:8
|
作者
Zhang ShenYi [1 ]
Zhang XianGuo [1 ]
Wang ChuiQin [1 ]
Shen GuoHong [1 ]
Jin Tao [1 ]
Zhang BinQuan [1 ]
Sun YueQiang [1 ]
Zhu GuangWu [1 ]
Liang JinBao [1 ]
Zhang XiaoXin [2 ]
Li JiaWei [2 ]
Huang Cong [2 ]
Han Ying [3 ]
机构
[1] Chinese Acad Sci, Ctr Space Sci & Appl Res, Beijing 100190, Peoples R China
[2] Natl Ctr Space Weather, Beijing 100081, Peoples R China
[3] Beijing Inst Petrochem Technol, Beijing 102617, Peoples R China
基金
中国国家自然科学基金;
关键词
geometrical factor; response function; particle radiation; space detection; FY-3;
D O I
10.1007/s11430-014-4853-0
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Geometric factor is the key parameter for inversion of particle spectrum in space particle detection. Traditional geometric factor is obtained through the method of numerical calculation with the actual structure of the detector as the input condition. The degree of accuracy for data inversion is reduced since traditional geometric factor fails to take into account the physical process of interaction between the particle and substance as well as the influence of factors such as the particle interference between different energy channels on the measurement result. Here we propose an improved geometrical factor calculation method, the concept of which is to conduct actual structural modelling of the detector in the GEANT4 program, consider the process of interaction between the particle and substance, obtain the response function of the detector to particles of different energy channels through the method of Monte Carlo simulation, calculate the influence of contaminated particle on the geometrical factor, and finally get the geometrical factors for different energy channels of the detector. The imrpoved geometrical factor obtained through the method has carried out inversion for the data of high energy protons detector on China's FY-3 satellite, the energy spectrum after which is more in line with the power law distribution recognized by space physics. The comparison with the measured result of POES satellite indicates that the FY-3 satellite data are in good accordance with the satellite data, which shows the method may effectively improve the quality of data inversion.
引用
收藏
页码:2558 / 2566
页数:9
相关论文
共 50 条
  • [21] Platform for monitoring accuracy of on orbit cross calibration : Infrared Atmospheric Sounder onboard FY-3 satellite
    Qi Cheng-Li
    Xu Han-Lie
    Hu Xiu-Qing
    Yin De-Kui
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2016, 35 (03) : 341 - 349
  • [22] DESIGN OF THE SECOND GENERATION MICROWAVE HUMIDITY SOUNDER (MWHS-II) FOR CHINESE METEOROLOGICAL SATELLITE FY-3
    Zhang Sheng Wei
    Li Jing
    Wang Zhenzhan
    Wang Hongjian
    Sun Maohua
    Jiang Jingshan
    He Jie Ying
    2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 4672 - 4675
  • [23] Medium-Energy Proton Detector Onboard the FY-4B Satellite
    Zhang, Huanxin
    Zhang, Shenyi
    Shen, Guohong
    Zhang, Xin
    Zong, Weiguo
    Guo, Jianguang
    Chen, Anqin
    Zhang, Liguo
    Zhang, Ruyi
    AEROSPACE, 2023, 10 (10)
  • [24] SATELLITE EQUIPMENT FOR MEASUREMENT OF HIGH ENERGY ELECTRONS AND PROTONS
    DALZIEL, R
    HARDEN, BN
    PAGE, DE
    THOMAS, GR
    THORPE, DG
    JOURNAL OF ATMOSPHERIC AND TERRESTRIAL PHYSICS, 1971, 33 (01): : 71 - &
  • [25] Calibration of the FY-3E particle sensors: High-Energy Particle Detector (HEPD)
    Hou, Donghui
    Zhang, Xiaoxin
    Wang, Jinhua
    Huang, Cong
    Li, Jiawei
    Zong, Weiguo
    Zhang, Shenyi
    Shen, Guohong
    Zhang, Xianguo
    Yuan, Bin
    Quan, Zida
    Ji, Wentao
    Zhou, Ping
    Yang, Yong
    Zhang, Pengfei
    Sun, Yueqiang
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)
  • [26] The High Energy Particle Detector onboard the CSES satellite
    Scotti, Valentina
    Osteria, Giuseppe
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [27] COMPARISON OF INFRARED 11μm WINDOW CHANNELS FOR MEDIUM RESOLUTION SPECTRAL IMAGER AND VISIBLE AND INFRARED RADIOMETER ON FY-3 METEOROLOGY SATELLITE
    Bi Yan-Meng
    Yang Zhong-Dong
    Lu Qi-Feng
    Zheng Zhao-Jun
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2009, 28 (05) : 330 - 334
  • [28] FY-3 Meteorological Satellite Visible Light Infrared Scanning Radiometer Cold Space Reference Sampling Area After Observing the Moon
    Zhang, E.
    Chen Shuaishuai
    Zhang Liyang
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2020, 39 (06)
  • [29] Radiation damage evaluation of the CCD detector induced by high energy protons
    Wang, Zujun
    Xue, Yuanyuan
    Zhang, Fengqi
    Bian, Jingying
    Ma, Wuying
    Yao, Zhibin
    He, Baoping
    Sheng, Jiangkun
    Dong, Guantao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 219 - 224
  • [30] LOW-ENERGY PROTONS AS A TOOL FOR HIGH-ENERGY VERTEX DETECTOR CALIBRATION
    CACCIA, M
    CASOLI, L
    GUAZZONI, P
    MARIOLI, D
    MERONI, C
    REDAELLI, N
    TORRETTA, D
    VEGNI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 254 (02): : 327 - 332