Transapical off-pump mitral valve repair with NeoChord implantation: A systematic review

被引:9
|
作者
Ahmed, Ahmed [1 ]
Abdel-Aziz, Tarek A. [2 ]
AlAsaad, Mohannad M. R. [2 ]
Majthoob, Motaz [2 ]
机构
[1] Ain Shams Univ, Fac Med, Dept Cardiothorac Surg, Cairo 11517, Egypt
[2] Dubai Hosp, Dept Cardiothorac Surg, Dubai, U Arab Emirates
关键词
mitral regurgitation; mitral valve repair; NeoChord DS1000; ANESTHETIC MANAGEMENT; ARTIFICIAL CHORDAE; REGURGITATION; OUTCOMES; DISEASE;
D O I
10.1111/jocs.15350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising outcomes. This study aims to conduct a systematic review of the published literature that discusses the technical feasibility and outcome of transapical off-pump MVr with NeoChord DS1000 device implantation in the treatment of degenerative MR. Methods: This review was performed according to the PRISMA statement. Databases searched in this review included Pubmed, Web of Science, Scopus, and Cochrane databases for systematic reviews. All English articles on humans reporting isolated MVr using NeoChord DS1000 device were included provided that basic preoperative data, operative specifications, and postoperative mortality and morbidity were reported. Results: This review included six studies comprised 249 patients who had NeoChord mitral procedure. Almost all patients included had severe MR (243/249, 97.6%). Operative success was achieved in 241 out of the 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia was reported in six patients (2.4%) and significant bleeding was reported in eight patients (3.2%). Conclusion: Awaiting more evidence, NeoChord mitral procedure appears to be a promising procedure that can be considered in selected cases.
引用
收藏
页码:1492 / 1498
页数:7
相关论文
共 50 条
  • [21] An early European experience with transapical off-pump mitral valve repair with NeoChord implantation (vol 54, pg 460, 2018)
    Colli, Andrea
    Manzan, Erica
    Aidietis, Audrius
    Rucinskas, Kestutis
    Bizzotto, Eleonora
    Besola, Laura
    Pradegan, Nicola
    Pittarello, Demetrio
    Janusauskas, Vilius
    Zakarkaite, Diana
    Drasutiene, Agne
    Lipnevicius, Arturas
    Danner, Bernhard C.
    Sievert, Horst
    Vaskelyte, Laura
    Schnelle, Nalan
    Salizzoni, Stefano
    Marro, Matteo
    Rinaldi, Mauro
    Kurnicka, Katarzyna
    Wrobel, Kristof
    Ceffarelli, Mariano
    Savini, Carlo
    Pacini, Davide
    Gerosa, Gino
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (06) : 1240 - 1240
  • [22] First in Switzerland: concomitant off-pump transapical transcatheter aortic valve implantation and mitral valve reconstruction with the NeoChord system
    Vasileios, Ntinopoulos
    David, Tueller
    Alain, Bernheim
    Nestoras, Papadopoulos
    Achim, Haeussler
    Sonja, Matter-Ensner
    Franz, Eberli
    Omer, Dzemali
    SWISS MEDICAL WEEKLY, 2019, 149 : w20168
  • [23] First in Man: Off-Pump Transapical Transcatheter Aortic Valve Implantation and Mitral Valve Repair
    Zierer, Andreas F.
    Kammler, Juergen
    Blessberger, Hermann
    Ay, Mahmut
    Steinwender, Clemens
    ANNALS OF THORACIC SURGERY, 2019, 107 (04): : E249 - E250
  • [24] Off-pump transapical mitral valve-in-ring implantation
    Zou, Yu
    Ferrari, Enrico
    von Segesser, Ludwig K.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (04) : 849 - 855
  • [25] Transapical off-pump Neochord implantation on bileaflet prolapse to treat severe mitral regurgitation
    Colli, Andrea
    Bellu, Roberto
    Pittarello, Demetrio
    Gerosa, Gino
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (04) : 554 - 556
  • [26] CHANGES IN MITRAL ANNULAR GEOMETRY AND CARDIAC FUNCTION AFTER TRANSAPICAL OFF PUMP MITRAL VALVE REPAIR WITH NEOCHORD IMPLANTATION
    Colli, Andrea
    Manzan, Erica
    Zucchetta, Fabio
    Bizzotto, Eleonora
    Besola, Laura
    Sarais, Cristiano
    Pittarello, Demetrio
    Bellu, Roberto
    Gerosa, Gino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A2018 - A2018
  • [27] Mid-term follow-up of echo-guided transapical off-pump mitral valve repair with neochord implantation
    Colli, A.
    Manzan, E.
    Besola, L.
    Bizzotto, E.
    Zucchetta, F.
    Bagozzi, L.
    Bellu, R.
    Sarais, C.
    Pittarello, D.
    Gerosa, G.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1238 - 1238
  • [28] Concomitant Transapical Transcatheter Aortic Valve Implantation and Transapical Mitral Valve Repair With NeoChord Implantation
    Stelzmueller, Marie-Elisabeth
    Zilberszac, Robert
    Heinrich, Nikolaus
    Mora, Bruno
    Laufer, Guenther
    Wisser, Wilfried
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (06) : 564 - 568
  • [29] THE IMPORTANCE OF THE LEAFLET-TO-ANNULAR MISMATCH INDEX FOR PATIENTS UNDERGOING ECHO GUIDED TRANSAPICAL OFF-PUMP MITRAL VALVE REPAIR WITH NEOCHORD IMPLANTATION
    Colli, Andrea
    Montagner, Matteo
    Azzolina, Danila
    Soriani, Nicola
    Besola, Laura
    Manzan, Erica
    Bizzotto, Eleonora
    Zucchetta, Fabio
    Bellu, Roberto
    Pittarello, Demetrio
    Gerosa, Gino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1792 - 1792
  • [30] Is trans-apical off-pump neochord implantation a safe and effective procedure for mitral valve repair?
    Salihi, Salih
    Ozalp, Bilhan
    Sacli, Hakan
    Kara, Ibrahim
    Koksal, Cengiz
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2019, 22 (06): : 319 - 324