Determination of electrophysical and structural properties of human cancellous bone and synthetic bone substitute material using impedance spectroscopy and X-ray powder diffraction

被引:2
|
作者
Haba, Yvonne [1 ]
Koeckerling, Martin [2 ]
Schick, Christoph [3 ]
Mittelmeier, Wolfram [1 ]
Bader, Rainer [1 ]
机构
[1] Univ Med Rostock, Dept Orthopaed, Biomech & Implant Technol Res Lab, Rostock, Germany
[2] Univ Rostock, Inst Chem, Inorgan Solid State Chem Grp, Rostock, Germany
[3] Univ Rostock, Inst Phys, Polymer Phys Grp, Rostock, Germany
关键词
human cancellous bone; synthetic bone; properties; impedance spectroscopy; X-ray powder diffraction; DIELECTRIC-PROPERTIES; BIOLOGICAL TISSUES; THERAPY; DENSITY;
D O I
10.5277/ABB-00978-2017-02
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrophysical stimulation is used to support fracture healing and bone regeneration For design optimization of electrostimulative implants, in combination with applied human donor bone or synthetic bone scaffolds, the knowledge of electrophysical properties is fundamental Hence further investigations of the structural properties of native and synthetic bone is of high interest to improve biofunctionality of bone scaffolds and subsequent healing of the bone defect The investigation of these properties was taken as an objective of this study Therefore, surgically extracted fresh cylindrical and consecutively ashed cancellous bone samples from human osteoarthritic femoral heads were characterized and compared to synthetic bone substitute material Thereby, impedance spectroscopy is used to determine the electrophysical properties and X-ray powder diffraction (XRD) for analysis of structural information of the bone samples Conductivity and permittivity of fresh and ashed cancellous bone amounted to 1.7.10(-2) S/m and 7.5.10(6) and 2.10(-5) S/m and 7.2.10(3), respectively Electrical conductivity and dielectric permittivity of bone scaffold resulted in 1.7-10(-7) S/m and 49 Analysis of the structural properties showed that the synthetic bone scaffolds made of Brushite exhibited some reflections which correspond to the native bone samples. The information in present study of the bone material (synthetic and autologous) could be used for later patient individual application of electrostimulative implants.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 50 条
  • [31] Analysis of crystalline structure of autogenous tooth bone graft material: X-Ray diffraction analysis
    Kim, Gyung-Wook
    Yeo, In-Sung
    Kim, Su-Gwan
    Um, In-Woong
    Kim, Young-Kyun
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2011, 37 (03) : 225 - 228
  • [32] Structural studies of crystalline thallium tellurides using Mossbauer effect, X-ray diffraction and X-ray photoelectron spectroscopy
    Aldon, L
    Lippens, PE
    Moubtassim, MLE
    OlivierFourcade, J
    Jumas, JC
    Gheorghiu, A
    Senemaud, C
    INTERNATIONAL CONFERENCE ON THE APPLICATIONS OF THE MOSSBAUER EFFECT - ICAME-95, 1996, 50 : 71 - 74
  • [33] Structural studies of biological & synthetic polymers using x-ray and neutron diffraction.
    Forsyth, VT
    Parrot, I
    Gardner, KH
    Lagan, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : D26 - D26
  • [34] Subject-specific mechanical properties of vertebral cancellous bone assessed using a low-dose X-ray device
    de Brosses, E. Sapin
    Briot, K.
    Kolta, S.
    Skalli, W.
    Roux, C.
    Mitton, D.
    IRBM, 2010, 31 (03) : 148 - 153
  • [35] Structure determination of coordination polymers of [Co(II)(Htrz)Cl2] by powder x-ray diffraction and x-ray absorption spectroscopy
    Hsu, I-Jui
    Chen, Bo-Hao
    Chuang, Yu-Chun
    Jang, Ling-Yun
    Chen, Jin-Ming
    Lee, Jey-Jau
    Lee, Jyh-Fu
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2016, 72 : S312 - S312
  • [36] Quantitative analysis of sulfated calcium carbonates using Raman spectroscopy and X-ray powder diffraction
    Kontoyannis, CG
    Orkoula, MG
    Koutsoukos, PG
    ANALYST, 1997, 122 (01) : 33 - 38
  • [37] Material strength determination in the shock compressed state using x-ray diffraction measurements
    Turneaure, Stefan J.
    Gupta, Y. M.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (12)
  • [38] Structural evidence for the desalination of akaganeite in the preservation of iron archaeological objects, using synchrotron X-ray powder diffraction and absorption spectroscopy
    Reguer, S.
    Mirambet, F.
    Dooryhee, E.
    Hodeau, J-L
    Dillmann, P.
    Lagarde, P.
    CORROSION SCIENCE, 2009, 51 (12) : 2795 - 2802
  • [39] An age related structural study of human lenses using X-ray diffraction
    Kang, G.
    Meek, K. M.
    Regini, J. W.
    INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2011, 92 (03) : A31 - A31
  • [40] Application of X-ray photoelectron spectroscopy to examine surface chemistry of cancellous bone and medullary contents to refine bone sample selection for nuclear DNA analysis
    Andronowski, Janna M.
    Mundorff, Amy Z.
    Davis, Reed A.
    Price, Eric W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (10) : 2074 - 2082