Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

被引:106
|
作者
Herz, PR
Chen, Y
Aguirre, AD
Schneider, K
Hsiung, P
Fujimoto, JG
Madden, K
Schmitt, J
Goodnow, J
Petersen, C
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] MIT, Div Comparat Med, Cambridge, MA 02139 USA
[4] LightLab Imaging, Westford, MA 01886 USA
关键词
D O I
10.1364/OL.29.002261
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A distally actuated, rotational-scanning micrometer endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-mum axial resolution by use of a femtosecond Cr:forsterite laser light source. The micrometer endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications. (C) 2004 Optical Society of America.
引用
收藏
页码:2261 / 2263
页数:3
相关论文
共 50 条
  • [21] In vivo measurement of retinal physiology with high-speed ultrahigh-resolution optical coherence tomography
    Srinivasan, V. J.
    Wojtkowski, M.
    Fujimoto, J. G.
    Duker, J. S.
    OPTICS LETTERS, 2006, 31 (15) : 2308 - 2310
  • [22] In vivo Ultrahigh-Resolution Ophthalmic Optical Coherence Tomography Using Gaussian-Shaped Supercontinuum
    Nishiura, Masahiro
    Kobayashi, Toshihiro
    Adachi, Muneyuki
    Nakanishi, Jun
    Ueno, Tokio
    Ito, Yasuki
    Nishizawa, Norihiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (01)
  • [23] A Micromotor Catheter for Intravascular Optical Coherence Tomography
    Wang, Tianshi
    van Soestl, Gijs
    van der Steen, Antonius F. W.
    ENGINEERING, 2015, 1 (01) : 15 - 17
  • [24] Optical clearing for luminal organ imaging with ultrahigh-resolution optical coherence tomography
    Liang, Yanmei
    Yuan, Wu
    Mavadia-Shukla, Jessica
    Lia, Xingde
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (08)
  • [25] Ultrahigh resolution catheter based in vivo imaging of the rabbit aorta with optical coherence tomography
    Brezinski, ME
    Tearney, GJ
    Boppart, SA
    Bouma, BE
    Pitris, C
    Southern, JF
    Fujimoto, JG
    CIRCULATION, 1997, 96 (08) : 3294 - 3294
  • [26] Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction
    Zawadzki, Robert J.
    Cense, Barry
    Zhang, Yan
    Choi, Stacey S.
    Miller, Donald T.
    Werner, John S.
    OPTICS EXPRESS, 2008, 16 (11) : 8126 - 8143
  • [27] Findings of secondary corneal amyloidosis with ultrahigh-resolution optical coherence tomography
    Araki-Sasaki, Kaoru
    Osakabe, Yasuhiro
    Fukuoka, Hideki
    Ideta, Ryuichi
    Hirano, Koji
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 2115 - 2119
  • [28] Quantitative Evaluation of Caries and Calculus with Ultrahigh-Resolution Optical Coherence Tomography
    Wang, Tai-Ang
    Trung, Nguyen Hoang
    Lee, Hsiang-Chieh
    Lee, Cheng-Kuang
    Tsai, Meng-Tsan
    Wang, Yen-Li
    BIOENGINEERING-BASEL, 2023, 10 (11):
  • [29] Ultrahigh-resolution optical coherence tomography of surgically closed macular holes
    Ko, Tony H.
    Witkin, Andre J.
    Fujimoto, James G.
    Chan, Annie
    Rogers, Adam H.
    Baumal, Caroline R.
    Schuman, Joel S.
    Drexler, Wolfgang
    Reichel, Elias
    Duker, Jay S.
    ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) : 827 - 836
  • [30] Stroboscopic ultrahigh-resolution full-field optical coherence tomography
    Moneron, G
    Boccara, AC
    Dubois, A
    OPTICS LETTERS, 2005, 30 (11) : 1351 - 1353