Comparative Analysis of Procedural Outcomes and Complications Between De Novo and Upgraded Cardiac Resynchronization Therapy

被引:9
|
作者
Nemer, David M. [1 ]
Patel, Divyang R. [1 ]
Madden, Ruth A. [1 ]
Wilkoff, Bruce L. [1 ]
Rickard, John W. [1 ]
Tarakji, Khaldoun G. [1 ]
Varma, Niraj [1 ]
Hussein, Ayman A. [1 ]
Wazni, Oussama M. [1 ]
Kanj, Mohamed [1 ]
Baranowski, Bryan [1 ]
Cantillon, Daniel J. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, Sect Cardiac Pacing & Electrophysiol, 9500 Euclid Ave,Desk J2-2, Cleveland, OH 44195 USA
关键词
biventricular; CRT; stenosis; upgrade; venous; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; TRANSVENOUS LEAD EXTRACTION; HEART-FAILURE; PACEMAKER; PREDICTORS;
D O I
10.1016/j.jacep.2020.07.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study compared rates of procedural success and complications between de novo cardiac resynchronization therapy (CRT) implantation versus upgrade, including characterization of technical challenges. BACKGROUND CRT upgrade is common, but data are limited on the incidence of procedural success and complications as compared to de novo implantation. METHODS All patients who underwent a transvenous CRT procedure at a single institution between 2013 and 2018 were reviewed for procedure outcome, 90-day complications, reasons for unsuccessful left ventricular lead delivery, and the presence of venous occlusive disease (VOD) that required a modified implantation technique. RESULTS Among 1,496 patients, 947 (63%) underwent de novo implantation and 549 (37%) underwent device upgrade. Patients who received a device upgrade were older (70 +/- 12 years vs. 68 +/- 13 years; p < 0.01), with a mate predominance (75% vs. 66%; p < 0.01) and greater prevalence of comorbidities. There was no difference in the rate of procedural success between de novo and upgrade CRT procedures (97% vs. 96%; p = 0.28) or 90-day complications (5.1% vs. 4.6%; p = 0.70). VOD was present in 23% of patients who received a device upgrade and was more common among patients with a dual-chamber versus a single-chamber device (26% vs. 9%; p < 0.001). Patients with and without VOD had a similar composite outcome of procedural failure or complication (8.0% vs. 7.8%; p = 1.0). CONCLUSIONS Rates of procedural success and complications were no different between de novo CRT implantations and upgrades. VOD frequently increased procedural complexity in upgrades, but alternative management strategies resulted in similar outcomes. Routine venography before CRT upgrade may aid in procedural planning and execution of these strategies. (C) 2021 by the American College of Cardiology Foundation.
引用
收藏
页码:62 / 72
页数:11
相关论文
共 50 条
  • [41] Association between frailty and adverse outcomes after cardiac resynchronization therapy: a systematic review and meta-analysis
    Li, Xiaowang
    Fang, Fei
    EUROPEAN GERIATRIC MEDICINE, 2025, 16 (01) : 165 - 177
  • [42] Complications of cardiac resynchronization therapy in patients with congestive heart failure
    NIU Hongxia HUA Wei WANG Fangzheng ZHANG Shu CHEN Keping and CHEN XinCentre of Arrhythmia Diagnosis and Treatment Fuwai Hospital Chinese Academy of Medical Sciences and Peking Union Medical College Beijing China
    Chinese Medical Journal, 2006, (06) : 449 - 453
  • [43] Predictors of device and procedure related complications with cardiac resynchronization therapy
    Giudici, M
    Faddis, M
    Almquist, A
    Yong, P
    CIRCULATION, 2003, 108 (17) : 346 - 347
  • [44] Complications of cardiac resynchronization therapy in patients with congestive heart failure
    Niu, HX
    Hua, W
    Wang, FZ
    Zhang, S
    Chen, KP
    Chen, X
    CHINESE MEDICAL JOURNAL, 2006, 119 (06) : 449 - 453
  • [46] Procedural and Clinical Outcomes of IS-CTO and De Novo CTO PCIs
    Khelimskii, Dmitrii
    Krestyaninov, Oleg
    Badoian, Aram
    Baranov, Aleksey
    Gorgulko, Alexander
    Manukian, Serezha
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B50 - B50
  • [47] The incidence and outcomes of delayed response to cardiac resynchronization therapy
    Li, Kebei
    Qian, Zhiyong
    Hou, Xiaofeng
    Wang, Yao
    Qiu, Yuanhao
    Sheng, Yufeng
    Qian, Xuesong
    Zhou, Yong
    Zou, Jiangang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (01): : 73 - 80
  • [48] Impact of Scar Burden on Outcomes of Cardiac Resynchronization Therapy
    Brooke, Kelly L.
    Webster, Tracy L.
    Xu, Yi-Zhou
    Chareonthaitawee, Panithaya
    Cha, Yong-Mei
    JOURNAL OF CARDIAC FAILURE, 2011, 17 (08) : S53 - S53
  • [49] Gender differences in outcomes from cardiac resynchronization therapy
    Lin, G
    Brady, PA
    Hayes, DL
    CIRCULATION, 2005, 112 (17) : U664 - U664
  • [50] Intra-procedural evaluation of a computational modelling method for cardiac resynchronization therapy
    Buliard, Samuel
    Nasser, Noumer
    Mansi, Tommaso
    Houle, Helene
    Ritter, Philippe
    Lafitte, Stephane
    EUROPACE, 2020, 22 (04): : 656 - 656