THE DESTRUCTION OF ESCHERICHIA COLI BIOFILMS USING HIGH-INTENSITY FOCUSED ULTRASOUND

被引:57
|
作者
Bigelow, Timothy A. [1 ,2 ,3 ]
Northagen, Trevor [3 ]
Hill, Thomas M. [4 ]
Sailer, Frances C. [4 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
[3] Univ N Dakota, Dept Elect Engn, Sch Engn & Mines, Grand Forks, ND 58201 USA
[4] Univ N Dakota, Dept Microbiol & Immunol, Sch Med & Hlth Sci, Grand Forks, ND 58201 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2009年 / 35卷 / 06期
基金
美国国家科学基金会;
关键词
Ultrasound therapy; Biofilm; STAPHYLOCOCCUS-EPIDERMIDIS; TISSUE EROSION; INFECTIONS; TECHNOLOGY; MECHANISM; BEHAVIOR; DEVICE;
D O I
10.1016/j.ultrasmedbio.2008.12.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-intensity focused ultrasound (HIFU) has shown great potential for replacing surgery in many applications. In this work, HIFU was used to destroy Escherichia coli (E. coli) biofilms that had been grown on chambered microscope slides. Biofilms are central to the pathogenesis and persistence of nosocomial (hospital-acquired) infections associated with indwelling medical devices. The slides were exposed to 9.1 mu s pulses at a pulse repetition frequency of 1000 Hz. The pulses were generated by a 1.1 MHz spherically focused source with a focal length of 6.3 cm and an active diameter of 7 cm. The peak rarefactional pressure for the pulses was varied as 3.1, 4.1, 5.2, 6.2 and 7.6 MPa in addition to a sham where the biofilms were not exposed. The effectiveness of the treatment was assessed by determining the number of colony forming units (CFU) remaining following exposure of the bacteria to HIFU. Most of the biofilms treated at the higher exposures of 6.2 and 7.6 MPa had no detectable CFU, indicating that bacteria in the biofilm were killed by the treatment or that treatment disrupted the biofilm and released bacteria from the slide. However, the ability of some bacteria to survive at the higher exposure settings needs to be resolved prior to implementing the treatment clinically. (E-mail: bigelow@iastate.edu). (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1026 / 1031
页数:6
相关论文
共 50 条
  • [41] Machining of Aluminium with MHz High-Intensity Focused Ultrasound
    Pudas, Topi
    Hyvonen, Jere
    Holmstrom, Axi
    Sillanpaa, Tom
    Lassila, Petri
    Makinen, Joni
    Kuronen, Antti
    Kotiaho, Tapio
    Salmi, Ari
    Haeggstrom, Edward
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [42] High-intensity focused ultrasound therapy: An overview for radiologists
    Kim, Young-Sun
    Kim, Hyunchul
    Choi, Min Joo
    Lim, Hyo Keun
    Choi, Dongil
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (04) : 291 - 302
  • [43] High-intensity focused ultrasound in the treatment of solid tumours
    Kennedy, JE
    NATURE REVIEWS CANCER, 2005, 5 (04) : 321 - 327
  • [44] Gaussian representation of high-intensity focused ultrasound beams
    Soneson, Joshua E.
    Myers, Matthew R.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (05): : 2526 - 2531
  • [45] Noninvasive Thermometry in High-Intensity Focused Ultrasound Ablation
    Zhou, Yufeng
    ULTRASOUND QUARTERLY, 2017, 33 (04) : 253 - 260
  • [46] Focal High-Intensity Focused Ultrasound Ablation of the Prostate
    Abrams, Lauren R.
    Koch, Michael O.
    Bahler, Clinton D.
    JOURNAL OF ENDOUROLOGY, 2021, 35 : S24 - S32
  • [47] HIGH-INTENSITY FOCUSED ULTRASOUND IN THE TREATMENT OF PROSTATIC TISSUE
    BIHRLE, R
    FOSTER, RS
    SANGHVI, NT
    FRY, FJ
    DONOHUE, JP
    UROLOGY, 1994, 43 (02) : 21 - 26
  • [48] High-Intensity Focused Ultrasound in the Treatment of Breast Cancer
    Feril, Loreto B., Jr.
    Fernan, Rodney L.
    Tachibana, Katsuro
    CURRENT MEDICINAL CHEMISTRY, 2021, 28 (25) : 5179 - 5188
  • [49] High-Intensity Focused Ultrasound in Dentistry: A Literature Review
    Tran, Minh Dien
    Ngo, Hien
    Fawzy, Amr
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (05) : 1168 - 1173
  • [50] New use found for the high-intensity focused ultrasound
    Hu, Z.
    Yang, X. Y.
    Liu, Y.
    EXPERT REVIEW OF MEDICAL DEVICES, 2007, 4 (05) : 681 - 682