Natural ventilation level assessment in a school building by CO2 concentration measures

被引:48
|
作者
Schibuola, Luigi [1 ]
Scarpa, Massimiliano [1 ]
Tambani, Chiara [1 ]
机构
[1] Univ IUAV Venice, Dept Design Culture & Art, Dorsoduro 2206, I-30123 Venice, Italy
来源
71ST CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION (ATI 2016) | 2016年 / 101卷
关键词
natural ventilation; school; indoor air quality; carbon dioxide; monitoring; INDOOR AIR-QUALITY;
D O I
10.1016/j.egypro.2016.11.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper considers the topic of natural ventilation in school buildings that is faced not only for energy saving, but also for the fundamental exigency of the indoor comfort. This analysis is developed by measuring the concentration of carbon dioxide as a significant indicator of IAQ when pollution is mainly due to the presence of people. In this paper are presented the results of a monitoring campaign of the CO2 levels carried on in classrooms. The measures show the criticality of IAQ with values often much higher than the limits specified by standard, but also the possibility to act effectively with the manual ventilation without excesses that could create comfort problems or waste of energy. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条
  • [41] Reconstruction of past CO2 concentration at a natural CO2 vent site using radiocarbon dating of tree rings
    Marzaioli, F
    Lubritto, C
    Battipaglia, G
    Passariello, I
    Rubino, M
    Rogalla, D
    Strumia, S
    Miglietta, F
    D'Onofrio, A
    Cotrufo, MF
    Terrasi, F
    RADIOCARBON, 2005, 47 (02) : 257 - 263
  • [42] Improving CO2 concentration, CO2 pollutant and occupants' thermal comfort in a residential building using genetic algorithm optimization
    Baghoolizadeh, Mohammadreza
    Rostamzadeh-Renani, Mohammad
    Hakimazari, Mohammad
    Rostamzadeh-Renani, Reza
    ENERGY AND BUILDINGS, 2023, 291
  • [43] Evaluation of CO2 and TVOC concentration in a school in Palma during the month of June
    Llabres-Morey, Maria-Angels
    Hormigos-Jimenez, Susana
    Merino, Mercedes del Rio
    BUILDING RESEARCH AND INFORMATION, 2025, 53 (1-2): : 95 - 119
  • [44] ANALYZER MEASURES BOTH CO AND CO2
    Arnaud, Celia H.
    Thayer, Ann M.
    CHEMICAL & ENGINEERING NEWS, 2009, 87 (19) : 34 - 34
  • [45] Influence of Natural Ventilation on Indoor PM2.5 Concentration in Residential Building
    Zhao, Li
    Chen, Chao
    Cao, Guoqing
    ENVIRONMENTAL TECHNOLOGY AND RESOURCE UTILIZATION II, 2014, 675-677 : 194 - +
  • [46] Relationship between CO2 at a rural site and integral measures of atmospheric stagnation, recirculation, and ventilation
    Isidro A. Pérez
    M. Luisa Sánchez
    M. Ángeles García
    Vanessa Paredes
    Naturwissenschaften, 2011, 98
  • [47] Relationship between CO2 at a rural site and integral measures of atmospheric stagnation, recirculation, and ventilation
    Perez, Isidro A.
    Luisa Sanchez, M.
    Angeles Garcia, M.
    Paredes, Vanessa
    NATURWISSENSCHAFTEN, 2011, 98 (07) : 565 - 574
  • [48] Renovation Measures for Reduction of Primary Energy Consumption and CO2 Emissions of Hospital Building
    Kadric, Diana
    Blaievic, Rejhana
    Bajric, Hadis
    Peco, Adna
    Kadric, Edin
    TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2025, 19 (01): : 26 - 33
  • [49] Photosynthetic Responses of Forest-Floor Moss Species to Elevated CO2 Level by a Natural CO2 Vents
    Zs. Csintalan
    A. Juhász
    Zs. Benkő
    A. Raschi
    Z. Tuba
    Cereal Research Communications, 2005, 33 : 177 - 180
  • [50] PHOTOSYNTHETIC RESPONSES OF FOREST-FLOOR MOSS SPECIES TO ELEVATED CO2 LEVEL BY A NATURAL CO2 VENTS
    Csintalan, Zs
    Juhasz, A.
    Benko, Zs
    Raschi, A.
    Tuba, Z.
    CEREAL RESEARCH COMMUNICATIONS, 2005, 33 (01) : 177 - 180