Comparison between the BACTEC 9240 and the Pall eBDS system for detection of bacterial platelet concentrate contamination

被引:6
|
作者
Savini, Vincenzo [1 ]
Balbinot, Andrea
Giancola, Raffaella
Quaglietta, Annamaria
Accorsi, Patrizia
D'Antonio, Domenico
Iacone, Antonio
机构
[1] Spirito Santo Hosp, Dept Transfus Med, Clin Microbiol & Virol Unit, I-65100 Pescara, Pe, Italy
关键词
CULTURE SYSTEM; BLOOD; TRANSFUSION; COMPONENTS; ORGANISMS; GROWTH;
D O I
10.1111/j.1537-2995.2009.02149.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Only two commercially available automated systems have been cleared by the FDA for screening of bacterial contamination in platelet (PLT) products. These are the Pall eBDS (Pall Corp.), based on measurement of oxygen consumption by contaminant organisms, and the BacT/ALERT (bioMErieux), revealing increasing carbon dioxide concentration due to bacterial growth. The authors compared the performance of the Pall eBDS with the BACTEC 9240 (bioMErieux) in detecting PLT contamination. Serial dilutions of 10 bacterial species frequently associated with PLT contamination were prepared in an apheresis PLT unit per organism. Units were from single donors. After 30 minutes from seeding PLT units, a volume of suspension achieving a final bacterial concentration of 1 to 10 colony-forming units/mL for each unit was inoculated in two Pall bags and a BACTEC bottle, and the same was done after 24 hours from seeding. Measurements were performed at 24 and 30 hours. Significant differences between the two instruments were only found when screening PLT units after 24 hours from seeding. The Pall system showed a higher sensitivity than BACTEC 9240, because it revealed 97 and 98% of positive samples at 24 and 30 hours of incubation, respectively, whereas the second detected 86 and 90% of contaminated products. Significance was lost after 35-hour incubation with the BACTEC 9240. By comparing the two instruments, their performances were found to be comparable; the Pall system appeared as a more suitable method when using 24 to 30 hours as times for readings, but the significant difference was lost after 35-hour incubation.
引用
收藏
页码:1217 / 1223
页数:7
相关论文
共 50 条
  • [21] Validation of the Bactec system for bacterial contamination of 361 cellular products
    McMannis, John D.
    Garcia, S.
    Tarrand, J.
    Sepulveda, C.
    TRANSFUSION, 2008, 48 (02) : 131A - 131A
  • [22] Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections
    Cockerill, FR
    Reed, GS
    Hughes, JG
    Torgerson, CA
    Vetter, EA
    Harmsen, WS
    Dale, JS
    Roberts, GD
    Ilstrup, DM
    Henry, NK
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) : 1469 - 1472
  • [23] Comparative Efficacy of BacT/ALERT and eBDS Methods for Primary Culture of Platelet Products for Prevention of Bacterial Contamination of Platelet Components
    Srivastava, Swati
    Jacobs, Michael R.
    Maitta, Robert W.
    TRANSFUSION, 2018, 58 : 204A - 204A
  • [24] COMPARISON OF THREE DIFFERENT METHODS FOR DETECTION OF BACTERIAL CONTAMINATION IN PLATELET CONCENTRATES
    Bian, G. H.
    Yang, C. H.
    Yang, H.
    Li, W. P.
    VOX SANGUINIS, 2012, 103 : 114 - 115
  • [25] Detection of bacterial contamination of platelet concentrates
    Pietersz, RNI
    Engelfriet, CP
    Reesink, HW
    VOX SANGUINIS, 2003, 85 (03) : 224 - 239
  • [26] Detection of bacterial contamination of platelet concentrates
    Pietersz, R. N. I.
    Engelfriet, C. P.
    Reesink, H. W.
    Wood, E. M.
    Winzar, S.
    Keller, A. J.
    Wilson, J. T.
    Henn, G.
    Mayr, W. R.
    Ramirez-Arcos, S.
    Goldman, M.
    Georgsen, J.
    Morel, P.
    Herve, P.
    Andeu, G.
    Assal, A.
    Seifried, E.
    Schmidt, M.
    Foley, M.
    Doherty, C.
    Coakley, P.
    Salami, A.
    Cadden, E.
    Murphy, W. G.
    Satake, M.
    de Korte, D.
    Bosnes, V.
    Kjeldsen-Kragh, J.
    McDonald, C.
    Brecher, M. E.
    Yomtovian, R.
    AuBuchon, J. P.
    VOX SANGUINIS, 2007, 93 (03) : 260 - 277
  • [27] Real-Time Detection of Bacterial Contamination in Platelet Concentrate for Point-of-Issue Testing
    Zhao, Z.
    Puleo, A.
    Rieder, R.
    TRANSFUSION, 2012, 52 : 205A - 205A
  • [28] Comparison of the VersaTREK blood culture system against the Bactec9240 system in patients with suspected bloodstream infections
    Dreyer, Andries W.
    Ismail, Nazir A.
    Nkosi, Deliwe
    Lindeque, Kathy
    Matthews, Marliza
    van Zyl, Danie G.
    Hoosen, Anwar A.
    ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2011, 10
  • [29] Comparison of the VersaTREK blood culture system against the Bactec9240 system in patients with suspected bloodstream infections
    Andries W Dreyer
    Nazir A Ismail
    Deliwe Nkosi
    Kathy Lindeque
    Marliza Matthews
    Danie G van Zyl
    Anwar A Hoosen
    Annals of Clinical Microbiology and Antimicrobials, 10
  • [30] Validation of an automatic culture system for detection of bacterial contamination in platelet concentrates
    Fayed, R
    Taylor, C
    Linauts, S
    TRANSFUSION, 2003, 43 (09) : 50A - 50A