Comparison between the BACTEC 9240 and the Pall eBDS system for detection of bacterial platelet concentrate contamination

被引:6
|
作者
Savini, Vincenzo [1 ]
Balbinot, Andrea
Giancola, Raffaella
Quaglietta, Annamaria
Accorsi, Patrizia
D'Antonio, Domenico
Iacone, Antonio
机构
[1] Spirito Santo Hosp, Dept Transfus Med, Clin Microbiol & Virol Unit, I-65100 Pescara, Pe, Italy
关键词
CULTURE SYSTEM; BLOOD; TRANSFUSION; COMPONENTS; ORGANISMS; GROWTH;
D O I
10.1111/j.1537-2995.2009.02149.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Only two commercially available automated systems have been cleared by the FDA for screening of bacterial contamination in platelet (PLT) products. These are the Pall eBDS (Pall Corp.), based on measurement of oxygen consumption by contaminant organisms, and the BacT/ALERT (bioMErieux), revealing increasing carbon dioxide concentration due to bacterial growth. The authors compared the performance of the Pall eBDS with the BACTEC 9240 (bioMErieux) in detecting PLT contamination. Serial dilutions of 10 bacterial species frequently associated with PLT contamination were prepared in an apheresis PLT unit per organism. Units were from single donors. After 30 minutes from seeding PLT units, a volume of suspension achieving a final bacterial concentration of 1 to 10 colony-forming units/mL for each unit was inoculated in two Pall bags and a BACTEC bottle, and the same was done after 24 hours from seeding. Measurements were performed at 24 and 30 hours. Significant differences between the two instruments were only found when screening PLT units after 24 hours from seeding. The Pall system showed a higher sensitivity than BACTEC 9240, because it revealed 97 and 98% of positive samples at 24 and 30 hours of incubation, respectively, whereas the second detected 86 and 90% of contaminated products. Significance was lost after 35-hour incubation with the BACTEC 9240. By comparing the two instruments, their performances were found to be comparable; the Pall system appeared as a more suitable method when using 24 to 30 hours as times for readings, but the significant difference was lost after 35-hour incubation.
引用
收藏
页码:1217 / 1223
页数:7
相关论文
共 50 条
  • [1] Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates
    Riedel, Stefan
    Siwek, Gregory
    Beekmann, Susan E.
    Richter, Sandra S.
    Raife, Thomas
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) : 2262 - 2264
  • [2] Pall eBDS: an enhanced bacterial detection system for screening platelet concentrates
    McDonald, CP
    Pearce, S
    Wilkins, K
    Colvin, J
    Robbins, S
    Colley, L
    Taylor, J
    Barbara, JAJ
    TRANSFUSION MEDICINE, 2005, 15 (04) : 259 - 268
  • [3] In-house validation of the BACTEC 9240 blood culture system for detection of bacterial contamination in platelet concentrates
    Dunne, WM
    Case, LK
    Isgriggs, L
    Lublin, DM
    TRANSFUSION, 2005, 45 (07) : 1138 - 1142
  • [4] Comparison of BACTEC 9240 and BacT/Alert Blood Culture Systems for Detection of Microbiological Contamination in Platelet Concentrates
    Givisiez, F. N.
    Cioffi, J. M.
    Basques, F. V.
    Santos, V. A.
    Rezende, G. C.
    Silva, R. M.
    Ferreira, A. M.
    Paiva, L. F.
    Oliveira, L. T.
    Tardelli, A. C.
    TRANSFUSION, 2014, 54 : 206A - 206A
  • [5] Impact of the Pall® enhanced bacterial detection system (Ebds) in a blood center heavily reliant on random platelet production
    Boothe, G
    Renner, TA
    Hupp, JL
    Giulitto, RM
    Wilkinson, SL
    Bunch, C
    TRANSFUSION, 2004, 44 (09) : 52A - 52A
  • [6] Detection of bacteria in pooled platelet concentrates using Pall eBDS
    Young, S
    Smith, R
    Kindig, S
    McCray, M
    McDonough, W
    Holme, S
    Cortus, M
    Lieu, T
    Nelson, EJ
    TRANSFUSION, 2005, 45 (03) : 26A - 26A
  • [7] Logistics and cost of implementing Pall® enhanced bacterial detection system (eBDS) in a 60%Pheresis/40% Random Platelet facility
    Boothe, G
    Renner, TA
    Walton, P
    Hupp, JL
    Giulitto, RM
    Pinkard, S
    Carey, PM
    Inscho, TS
    Wilkinson, SL
    TRANSFUSION, 2004, 44 (09) : 181A - 181A
  • [8] Comparative assessment of the PALL enhanced bacterial detection system and the Becton Dickinson Bactec 9,240 fluorescent system for detecting bacterial contamination in pooled platelet concentrates
    Anyaegbu, CC
    Osoba, AO
    Abdelaal, MA
    Hafiz, K
    Anwar, F
    Woodburn, S
    TRANSFUSION, 2005, 45 (03) : 26A - 27A
  • [9] Bacteria growth in platelet additive solution: Detection with Pall eBDS
    Cortus, MA
    Chong, CY
    Le, C
    Yu, JC
    Holme, S
    TRANSFUSION, 2004, 44 (09) : 45A - 46A
  • [10] Performance evaluation of the Pall eBDS bacterial detection method and direct comparison with BacT/Alert, PH, and swirling
    Nguyen, KAT
    Yamamoto, T
    Sandhu, H
    TRANSFUSION, 2004, 44 (09) : 25A - 25A