Determination of trace levels of diosmin in a pharmaceutical preparation by adsorptive stripping voltammetry at a glassy carbon electrode

被引:24
|
作者
El-Shahawi, M. S.
Bashammakh, A. S.
El-Mogy, T.
机构
[1] King Abdulaziz Univ, Fac Sci, Dept Chem, Jeddah 21589, Saudi Arabia
[2] Mansoura Univ, Dept Chem, Fac Sci Damietta, Mansoura 34517, Egypt
关键词
D O I
10.2116/analsci.22.1351
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A systematic study on the electrochemical behavior of diosmin in Britton-Robinson buffer (pH 2.0 - 10.0) at a glassy carbon electrode (GCE) was made. The oxidation process of the drug was found to be quasi-reversible with an adsorption-controlled step. The adsorption stripping response was evaluated with respect to various experimental conditions, such as the pH of the supporting electrolyte, the accumulation potential and the accumulation time. The observed anodic peak current at +0.73 V vs. Ag/AgCl reference electrode increased linearly over two orders of magnitude from 5.0 x 10(-8) M to 9.0 x 10(-6) M. A limit of detection down to 3.5 x 10(-8) M of diosmin at the GCE was achieved with a mean recovery of 97 +/- 2.1%. Based on the electrochemical data, an open-circuit accumulation step in a stirred sample solution of BR at pH 3.0 was developed. The proposed method was successfully applied to the determination of the drug in pharmaceutical formulations. The results compared favorably with the data obtained via spectrophotometric and HPLC methods.
引用
收藏
页码:1351 / 1354
页数:4
相关论文
共 50 条
  • [21] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Marcelina Łysoń
    Anna Górska
    Beata Paczosa-Bator
    Robert Piech
    Electrocatalysis, 2021, 12 : 641 - 649
  • [22] Adsorptive potentiometric stripping analysis of trace tamoxifen at a glassy carbon electrode
    Wang, J
    Cai, XH
    Fernandes, JR
    Ozsoz, M
    Grant, DH
    TALANTA, 1997, 45 (02) : 273 - 278
  • [23] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Lyson, Marcelina
    Gorska, Anna
    Paczosa-Bator, Beata
    Piech, Robert
    ELECTROCATALYSIS, 2021, 12 (06) : 641 - 649
  • [24] DETERMINATION OF PHOSPHATE BY CATHODIC STRIPPING VOLTAMMETRY AT A GLASSY CARBON ELECTRODE
    COX, JA
    CHENG, KH
    ANALYTICAL LETTERS, 1974, 7 (10) : 659 - 670
  • [25] Adsorptive cathodic stripping voltammetry determination of ultra trace levels of cobalt
    Laleh Hosseinzadeh
    Shahryar Abbasi
    Hossein Khani
    Zahra Khani
    Transition Metal Chemistry, 2009, 34 : 425 - 430
  • [26] Adsorptive cathodic stripping voltammetry determination of ultra trace levels of cobalt
    Hosseinzadeh, Laleh
    Abbasi, Shahryar
    Khani, Hossein
    Khani, Zahra
    TRANSITION METAL CHEMISTRY, 2009, 34 (04) : 425 - 430
  • [27] Determination of trace levels of niguldipine in urine and blood by adsorptive stripping voltammetry at the hanging mercury drop electrode
    Stubauer, G
    Obendorf, D
    ANALYST, 1996, 121 (03) : 351 - 356
  • [28] Catalytic adsorptive stripping voltammetry at a carbon paste electrode for the determination of amiodarone
    Liu Ning
    Gao Wei
    Song Jun-Feng
    CHINESE JOURNAL OF CHEMISTRY, 2006, 24 (11) : 1657 - 1661
  • [29] Determination of oleuropein using multiwalled carbon nanotube modified glassy carbon electrode by adsorptive stripping square wave voltammetry
    Cittan, Mustafa
    Kocak, Suleyman
    Celik, Ali
    Dost, Kenan
    TALANTA, 2016, 159 : 148 - 154
  • [30] Mercury Thin Film at Glassy Carbon Electrode for Adsorptive Stripping Voltammetric Determination of Captopril in Pharmaceutical Samples
    Zargar, Behrooz
    Parham, Hooshang
    Hatamie, Amir
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (03): : 344 - 357