3D analysis of bone formation around titanium implants using micro computed tomography (μCT)

被引:5
|
作者
Bernhardt, Ricardo [1 ]
Scharnweber, Dieter [1 ]
Muller, Bert [2 ]
Beckmann, Felix [3 ]
Goebbels, Juergen
Jansen, John [5 ]
Schliephake, Henning [4 ,6 ]
Worch, Hartmut [1 ]
机构
[1] Tech Univ Dresden, Max Bergmann Ctr Biomat, D-01062 Dresden, Germany
[2] Swiss Fed Inst Technol, Comp Vis Lab, CH-8029 Zurich, Switzerland
[3] GKSS Forschungszentrum Geesthacht GmbH, D-21502 Geesthacht, Germany
[4] Bundesanstalt Mat Forsch & Prufung, D-12205 Berlin, Germany
[5] Radboud Univ Nijmegen, Dept Biomat, NL-6500 HB Nijmegen, Netherlands
[6] George Augusta Univ, Dept Oral & Maxillofacial Surg, D-37027 Gottingen, Germany
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY V | 2006年 / 6318卷
关键词
micro computed tomography; synchrotron radiation; titanium implants; osseointegration; 3D analysis;
D O I
10.1117/12.681000
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The quantitative analysis of bone formation around biofunctionalised metallic implants is an important tool for the further development of implants with higher success rates. This is, nowadays, especially important in cases of additional diseases like diabetes or osteoporosis. Micro computed tomography (ktCT), as non-destructive technique, offers the possibility for quantitative three-dimensional recording of bone close to the implant's surface with micrometer resolution, which is the range of the relevant bony structures. Within different animal models using cylindrical and screw-shaped Ti6A14V implants we have compared visualization and quantitative analysis of newly formed bone by the use of synchrotron-radiation-based CT-systems in comparison with histological findings. The SR mu CT experiments were performed at the beamline BW5 (HASYLAB at DESY, Hamburg, Germany) and at the BAMline (BESSY, Berlin, Germany). For the experiments, PMMA-embedded samples were prepared with diameters of about 8 mm, which contain in the center the implant surrounded by the bony tissue. To (locally) quantify the bone formation, models were developed and optimized. The comparison of the results obtained by SR mu CT and histology demonstrates the advantages and disadvantages of both approaches, although the bone formation values for the different biofunctionalized implants are identical within the error bars. SR mu CT allows the clear identification of fully mineralized bone around the different titanium implants. As hundreds of virtual slices were easily generated for the individual samples, the quantification and interactive bone detection led to conclusions of high precision and statistical relevance. In this way, SR mu CT in combination with interactive data analysis is proven to be more significant(1) with respect to classical histology.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Micro-computerised tomography optimisation for the measurement of bone mineral density around titanium dental implants
    Departments of Oral Rehabilitation and Oral Sciences, Faculty of Dentistry, University of Otago, Dunedin 9054, New Zealand
    J. Biomech. Sci. Eng., 1 (2-10):
  • [22] 3D micro-CT analysis of cancellous bone architecture
    Rossi, M
    Casali, F
    Romani, D
    Carabini, ML
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 349 - 358
  • [23] Analysis of Mandibular Structure Using 3D Facial Computed Tomography
    Jung, Su Young
    Shin, Seung Youp
    Lee, Kun Hee
    Eun, Young Gyu
    Lee, Young Chan
    Kim, Sung Wan
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2014, 151 (05) : 760 - 764
  • [24] Extracting 3D information on bone remodeling in the proximity of titanium implants in SRμCT image volumes
    Sarve, Hamid
    Lindblad, Joakim
    Borgefors, Gunilla
    Johansson, Carina B.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2011, 102 (01) : 25 - 34
  • [25] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Ito, M
    JOURNAL OF BONE AND MINERAL METABOLISM, 2005, 23 (Suppl 1) : 115 - 121
  • [26] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Masako Ito
    Journal of Bone and Mineral Metabolism, 2005, 23 : 115 - 121
  • [27] Reducing artefacts in industrial 3D computed tomography (CT)
    Kasperl, S
    Bauscher, I
    Hassler, U
    Markert, H
    Schröpfer, S
    VISION MODELING, AND VISUALIZATION 2002, PROCEEDINGS, 2002, : 51 - 57
  • [28] Surface area analysis of dental implants using micro-computed tomography
    Schicho, Kurt
    Kastner, Johann
    Klingesberger, Roman
    Seemann, Rudolf
    Enislidis, Georg
    Undt, Gerhard
    Wanschitz, Felix
    Figl, Michael
    Wagner, Arne
    Ewers, Rolf
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) : 459 - 464
  • [29] Visualization of human cortical bone microstructure by high resolution 3D micro-computed tomography
    Cooper, DML
    Hallgrimsson, B
    FASEB JOURNAL, 2002, 16 (05): : A1100 - A1100
  • [30] Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material: A histological, histomorphometric, and micro-computed tomography evaluation
    Trento, Guilherme
    de A. Carvalho, Pedro Henrique
    de C. Reis, Erik N. R.
    Spin-Neto, Rubens
    Bassi, Ana Paula F.
    Pereira-Filho, Valfrido Antonio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (02) : 177 - 185