Wearable Devices Suitable for Monitoring Twenty Four Hour Heart Rate Variability in Military Populations

被引:87
|
作者
Hinde, Katrina [1 ]
White, Graham [1 ]
Armstrong, Nicola [1 ]
机构
[1] Def & Sci Technol Lab, Human & Social Sci Grp, Salisbury SP4 0JQ, Wilts, England
关键词
wearable technology; reliability; validity; occupational groups; long term; heart rate variability; PRESSURE;
D O I
10.3390/s21041061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart rate variability (HRV) measurements provide information on the autonomic nervous system and the balance between parasympathetic and sympathetic activity. A high HRV can be advantageous, reflecting the ability of the autonomic nervous system to adapt, whereas a low HRV can be indicative of fatigue, overtraining or health issues. There has been a surge in wearable devices that claim to measure HRV. Some of these include spot measurements, whilst others only record during periods of rest and/or sleep. Few are capable of continuously measuring HRV (>= 24 h). We undertook a narrative review of the literature with the aim to determine which currently available wearable devices are capable of measuring continuous, precise HRV measures. The review also aims to evaluate which devices would be suitable in a field setting specific to military populations. The Polar H10 appears to be the most accurate wearable device when compared to criterion measures and even appears to supersede traditional methods during exercise. However, currently, the H10 must be paired with a watch to enable the raw data to be extracted for HRV analysis if users need to avoid using an app (for security or data ownership reasons) which incurs additional cost.
引用
收藏
页码:1 / 20
页数:19
相关论文
共 50 条
  • [21] Twenty-four-hour ambulatory blood pressure and heart rate monitoring in combat-related posttraumatic stress disorder
    Muraoka, MY
    Carlson, JG
    Chemtob, CM
    JOURNAL OF TRAUMATIC STRESS, 1998, 11 (03) : 473 - 484
  • [22] Twenty-four hour non-invasive ambulatory blood pressure and heart rate monitoring in Parkinson's Disease
    Stuebner, Eva
    Vichayanrat, Ekawat
    Low, David A.
    Mathias, Christopher J.
    Isenmann, Stefan
    Haensch, Carl-Albrecht
    FRONTIERS IN NEUROLOGY, 2013, 4
  • [23] Examining weekly heart rate variability changes: a comparison between wearable devices running head: weekly heart rate variability changes
    Ruiz-Alias, Santiago A.
    Marcos-Blanco, Aitor
    Clavero-Jimeno, Antonio
    Garcia-Pinillos, Felipe
    SPORTS ENGINEERING, 2022, 25 (01)
  • [24] Assessing the Clinical Utility of a Wearable Device for Physiological Monitoring of Heart Rate Variability in Military Service Members with Traumatic Brain Injury
    Uomoto, Jay M.
    Skopp, Nancy
    Jenkins-Guarnieri, Michael
    Reini, Josh
    Thomas, Drew
    Adams, Robert J.
    Tsui, Megan
    Miller, Shaun R.
    Scott, Beverly R.
    Pasquina, Paul F.
    TELEMEDICINE AND E-HEALTH, 2022, 28 (10) : 1496 - 1504
  • [25] A Wearable Device for Physical Activity Monitoring With Built-in Heart Rate Variability
    Dinh, Anh
    Teng, Daniel
    Chen, Li
    Ko, Seok-Bum
    Shi, Yang
    McCrosky, Carl
    Basran, Jenny
    Del Bello-Hass, Vanina
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1272 - 1275
  • [26] Acoustic Sensing as a Novel Wearable Approach for Heart Rate Variability Monitoring at the Wrist
    Sharma, Piyush
    Rodriguez-Villegas, Esther
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [27] Heart rate estimation from photoplethysmography signal for wearable health monitoring devices
    Arunkumar, K. R.
    Bhaskar, M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 50 : 1 - 9
  • [28] Twenty-four-hour ambulatory blood pressure monitoring
    Bugeja, Ann
    Akbari, Ayub
    Hiremath, Swapnil
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2022, 194 (47) : E1615 - E1615
  • [29] Twenty four hour esophageal pH monitoring in healthy individuals
    Manterola, C
    Garrido, L
    Munoz, S
    REVISTA MEDICA DE CHILE, 1997, 125 (11) : 1313 - 1318
  • [30] Twenty-four hour ambulatory blood pressure monitoring
    Lüders, S
    Franz, IW
    Hilgers, KF
    Homuth, V
    Mengden, T
    Tholl, U
    Eckert, S
    Sanner, B
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2005, 130 (46) : 2664 - 2668