Transient Grounding Characteristics of an Actual Wind Turbine Generator System at a Low-resistivity Site

被引:15
|
作者
Yamamoto, Kazuo [1 ]
Yanagawa, Shunichi [2 ]
Sekioka, Shozo [3 ]
Yokoyama, Shigeru [4 ]
机构
[1] Kobe City Coll Technol, Dept Elect Engn, Nishi Ku, Kobe, Hyogo 6512194, Japan
[2] Shoden Co, Techno Ctr, Inage Ku, Chiba 2630002, Japan
[3] Shonan Inst Technol, Fac Engn, Kanagawa 2518511, Japan
[4] CRIEPI, Elect Power Engn Res Lab, Yokosuka, Kanagawa 2400196, Japan
关键词
lightning; wind turbine generator system; overvoltage; transient grounding characteristics; low-voltage system; LIGHTNING OVERVOLTAGES;
D O I
10.1002/tee.20488
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to exploit high wind conditions, wind turbine generator systems are often constructed in places where few tall Structures exist; therefore, they Lire often Struck by lightning. Much of the damage caused by lightning is from the resulting breakdown and malfunction of the electrical, communication, and control systems inside the wind turbine generator system; these breakdowns call be attributed to it rise in electric potential both within the system and in the surroundings due to lightning Impulse tests were conducted Oil it wind turbine generator system at it disposal site where the conductivity of the ground was very low, like that found oil the surface of the sea. The rise in ground potential of the system, and around its foundation, was measured. When it wind turbine generator system is constructed Lit a site where the grounding resistivity is very low, the potential rise at the wave front typically becomes larger than that of the steady state because of the inductivity of the grounding system. Therefore, it is very important that the transient characteristics of the grounding system are well understood. (C) 2010 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [31] Studies on steady-state characteristics of a hybrid wind turbine generator system
    Hasegawa, Chihiro
    Tatsuta, Fujio
    Nishikata, Shoji
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1495 - 1500
  • [32] Estimation of peak transient voltages at wind turbine generator terminals
    Dzhankhotov, Valentin
    Pyrhonen, Juha
    Paakkonen, Mikko
    WIND ENERGY, 2015, 18 (06) : 1123 - 1129
  • [33] Wind farm grounding system design for transient currents
    Ukar, Olatz
    Zamora, Inmaculada
    RENEWABLE ENERGY, 2011, 36 (07) : 2004 - 2010
  • [34] OPTIMUM SELECTION OF A WIND TURBINE GENERATOR SYSTEM
    SHULTIS, JK
    POCH, LA
    ECKHOFF, ND
    JOURNAL OF ENERGY, 1979, 3 (03): : 145 - 150
  • [35] Design of wind turbine generator control system
    Chen Guiyou
    Zhou Li
    Sun Tongjing
    Wang Zhongmin
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 1636 - +
  • [36] Yaw control system for wind turbine generator
    Xu, De
    Sun, Tongjing
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1996, 17 (03): : 235 - 239
  • [37] Bearing resistance of wind turbine generator system
    Aso, Toshiyuki
    Aida, Tomoyuki
    Seki, Kazuichi
    IEEJ Transactions on Industry Applications, 2014, 134 (04) : 421 - 428
  • [38] Bearing Resistance of Wind Turbine Generator System
    Aso, Toshiyuki
    Aida, Tomoyuki
    Seki, Kazuichi
    ELECTRICAL ENGINEERING IN JAPAN, 2016, 194 (02) : 64 - 73
  • [39] Performance characteristics of a practical scale wind turbine generating system using a shaft generator system
    Tatsuta, Fujio
    Nishikata, Shoji
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 3553 - 3562
  • [40] Comparison and evaluation of induction generator models in wind turbine systems for transient stability of power system
    Li, H.
    Chen, Z.
    Han, L.