Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer

被引:12
|
作者
Li, Zhiping [1 ]
Zeng, Jianshuang [1 ]
Wang, Zi [1 ]
Zhu, Hong [1 ]
Wei, Yuquan [1 ,2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Ctr Canc, Dept Abdominal Oncol, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, State Key Lab Biotherapy, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp, Ctr Canc, Chengdu 610041, Sichuan, Peoples R China
关键词
gastric cancer; intensity-modulated radiotherapy; volumetric modulated arc therapy; dosimetric comparison; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; INDUCED LIVER-DISEASE; SINGLE-ARC; HEAD; CHEMORADIOTHERAPY; ADENOCARCINOMA; CARCINOMA; TOXICITY; VMAT;
D O I
10.3892/ol.2014.2363
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to compare radiotherapy treatment plans for gastric cancer using intensity-modulated radiotherapy (IMRT) and single/double-arc volumetric modulated arc therapy (SA/DA-VMAT) delivery techniques. A total of 29 postoperative gastric cancer patients were enrolled in this study and each patient was scheduled 5-field IMRT (5F-IMRT), 7-field IMRT (7F-IMRT), SA-VMAT and DA-VMAT techniques. Dose-volume histogram statistics, conformal index (CI), homogeneity index (HI) and monitor units (MUs) were analyzed to compare treatment plans. The DA-VMAT plans exceeded the other three methods in terms of planning tumor volume dose and organs at risk in the kidneys, but not in the liver. DA-VMAT exhibited a better mean CI (0.87 +/- 0.03) and HI (0.10 +/- 0.01) than the other techniques. In addition, for the kidneys the dose sparing (V13, V18 and mean kidney dose) was improved by DA-VMAT plans. Similar results were observed for MUs. However, 5F-IMRT showed a marginal advantage in V30 and mean dose in normal liver when compared with DA-VMAT. The results of this study suggest that DA-VMAT provides improved tumor coverage when compared with 5F-IMRT, 7F-IMRT and SA-VMAT; however, DA-VMAT exhibits no advantage in liver protection when compared with 5F-IMRT. Further studies are required to establish differences in treatment outcomes among the four technologies.
引用
收藏
页码:1427 / 1434
页数:8
相关论文
共 50 条
  • [21] Dosimetric Comparison of Volumetric Arc Therapy and Intensity Modulated Radiotherapy for Glioblastoma Treatment
    Kaptan, I.
    Ugurluer, G.
    Ispir, B.
    Akdeniz, Y.
    Serin, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [22] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [23] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [24] SMARTARC-BASED VOLUMETRIC MODULATED ARC THERAPY FOR OROPHARYNGEAL CANCER: A DOSIMETRIC COMPARISON WITH BOTH INTENSITY-MODULATED RADIATION THERAPY AND HELICAL TOMOTHERAPY
    Clemente, Stefania
    Wu, BinBin
    Sanguineti, Giuseppe
    Fusco, Vincenzo
    Ricchetti, Francesco
    Wong, John
    McNutt, Todd
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1248 - 1255
  • [25] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [26] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy E.
    Rashed Y.A.
    AlKhaldi M.
    Day E.
    Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [27] Intensity modulated radiation therapy versus volumetric intensity modulated arc therapy
    Rana, Suresh
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2013, 60 (03): : 81 - 83
  • [28] Radiotherapy for maxillary sinus carcinoma: dosimetric comparison of volumetric modulated arc therapy with 0° and 90° collimator intensity modulated radiation therapy
    Sang, Yong
    Shan, Guoping
    Shao, Kainan
    Hu, Fujun
    Chen, Jing
    JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (1-2) : 53 - 58
  • [29] Volumetric Modulated Arc Therapy for Head and Neck Cancer: A Dosimetric and Treatment Planning Comparison with Intensity Modulated Radiotherapy Techniques
    Goswami, Brijesh
    Yadav, Suresh
    Jain, Rakesh Kumar
    Goswami, Pradeep
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (03)
  • [30] A Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT) and Non-Coplanar Intensity Modulated Radiation Therapy (IMRT) for Nasal Cavity and Paranasal Sinus Cancer
    Jeong, Y.
    Lee, S.
    Kwak, J.
    Cho, I.
    Yoon, S.
    Kim, J.
    Park, J.
    Choi, E.
    Song, S.
    Kim, Y.
    Kim, S.
    Joo, J.
    Ahn, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S865 - S865