Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement

被引:29
|
作者
Hoshide, Satoshi [1 ]
Yoshihisa, Akiomi [2 ,3 ]
Tsuchida, Fumihiro [4 ]
Mizuno, Hiroyuki [1 ]
Teragawa, Hiroki [5 ]
Kasai, Takatoshi [6 ]
Koito, Hitoshi [7 ]
Ando, Shin-ichi [8 ]
Watanabe, Yoshihiko [9 ]
Takeishi, Yasuchika [2 ]
Kario, Kazuomi [1 ]
机构
[1] Jichi Med Univ, Div Cardiovasc Med, Sch Med, Shimotsuke, Tochigi, Japan
[2] Fukushima Med Univ, Dept Cardiovasc Med, Fukushima, Japan
[3] Fukushima Med Univ, Dept Clin Lab Sci, Sch Hlth Sicence, Fukushima, Japan
[4] Yabuki Hosp, Dept Pulm Med, Yamagata, Japan
[5] JR Hiroshima Hosp, Dept Cardiovasc Med, Hiroshima, Japan
[6] Juntendo Univ, Dept Cardiovasc Med, Cardiovasc Resp Sleep Med, Grad Sch Med, Tokyo, Japan
[7] Misugikai Otokoyama Hosp, Dept Internal Med, Kyoto, Japan
[8] Kyushu Univ Hosp, Sleep Apnea Ctr, Fukuoka, Japan
[9] Nippon Dent Univ Hosp, Dept Internal Med, Tokyo, Japan
关键词
Pulse transit time; Beat-to-beat; Blood pressure variability; Continuous blood pressure monitoring; SLEEP; VARIABILITY; APNEA; HYPERTENSION; ANESTHESIA; MANAGEMENT; SEVERITY;
D O I
10.1038/s41440-022-00899-z
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Pulse transit time (PTT), which refers to the travel time between two arterial sites within the same cardiac cycle, has been developed as a novel cuffless form of continuous blood pressure (BP) monitoring. The aim of this study was to investigate differences in BP parameters, including BP variability, between those assessed by beat-to-beat PTT-estimated BP (eBP(BTB)) and those assessed by intermittent PTT-estimated BP at fixed time intervals (eBP(INT)) in patients suspected of having sleep disordered breathing (SDB). In 330 patients with SDB (average age, 66.8 +/- 11.9 years; 3% oxygen desaturation index [ODI], 21.0 +/- 15.0/h) from 8 institutes, PTT-estimated BP was continuously recorded during the nighttime. The average systolic eBP(BTB), maximum systolic and diastolic eBP(BTB), standard deviation (SD) of systolic and diastolic eBP(BTB), and coefficient variation (CV) of systolic and diastolic eBP(BTB) were higher than the respective values of eBP(INT) (all P < 0.05). Bland-Altman analysis showed a close agreement between eBP(BTB) and eBP(INT) in average systolic BP and SD and CV of systolic BP, while there were disagreements in both minimum and maximum values of eBP(BTB) and eBP(INT) in patients with high systolic BP (P < 0.05). Although systolic BP variability incrementally increased according to the tertiles of 3%ODI in both eBP(BTB) and eBP(INT) (all P < 0.05), there was no difference in this tendency between eBP(BTB) and eBP(INT). In patients with suspected SDB, the difference between e eBP(BTB) and eBP(INT) was minimal, and there were disagreements regarding both the minimum and maximum BP. However, there were agreements in regard to the index of BP variability between eBP(BTB) and eBP(INT).
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [31] Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement
    Wang, Ting-Wei
    Lin, Shien-Fong
    SENSORS, 2020, 20 (03)
  • [32] Beat-to-beat blood pressure measurement using a cuffless device does not accurately reflect invasive blood pressure
    Moharram, Mohammed A.
    Wilson, Luke C.
    Williams, Michael J. A.
    Coffey, Sean
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2020, 5
  • [33] Beat-to-beat measurement of the finger arterial pressure pulse shape index at rest and during exercise
    Raamat, R
    Jagomägi, K
    Talts, J
    Toska, K
    Walloe, L
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2003, 23 (02) : 87 - 91
  • [34] Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring
    Kim, Joshua
    Chou, En-Fan
    Le, Jamie
    Wong, Sabrina
    Chu, Michael
    Khine, Michelle
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
  • [35] Beat-to-Beat Blood Pressure Variability and Cognition in the MIDUS Study
    Sweigert, Joshua
    McKinley, Paula
    Lachman, Margie
    Gruenewald, Tara
    Seeman, Teresa
    Love, Gayle
    Weinstein, Maxine
    McIntyre, Kathleen
    Duong, Jimmy
    Sloan, Richard P.
    PSYCHOSOMATIC MEDICINE, 2017, 79 (04): : A154 - A155
  • [36] Is the blood velocity beat-to-beat variation in the descending aorta similar to the arterial pulse pressure variation?
    M Feissel
    JL Teboul
    A Cariou
    I Mangin
    S Darfin
    O Ruyer
    JP Faller
    Critical Care, 6 (Suppl 1):
  • [37] BEAT-TO-BEAT VARIABILITY OF HEART INTERVAL AND BLOOD PRESSURE.
    De Boer, Roel W.
    Karemaker, John M.
    Strackee, Jan
    1600, (04):
  • [38] Reliability of beat-to-beat blood pressure variability in older adults
    Lohman, Trevor
    Sible, Isabel J.
    Shenasa, Fatemah
    Engstrom, Allison C.
    Kapoor, Arunima
    Alitin, John Paul M.
    Gaubert, Aimee
    Thayer, Julian F.
    Ferrer, Farrah
    Nation, Daniel A.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [39] Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation
    Fleischhauer, Vincent
    Feldheiser, Aarne
    Zaunseder, Sebastian
    SENSORS, 2022, 22 (18)
  • [40] Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise
    Porta, A.
    Gasperi, C.
    Nollo, G.
    Lucini, D.
    Pizzinelli, P.
    Antolini, R.
    Pagani, M.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (04) : 331 - 337