Accurate calibration of a stereo-vision system in image-guided radiotherapy

被引:9
|
作者
Liu, Dezhi [1 ]
Li, Shidong [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
radiotherapy; patient positioning; stereo-vision; calibration;
D O I
10.1118/1.2362873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image-guided radiotherapy using a three-dimensional (3D) camera as the on-board surface imaging system requires precise and accurate registration of the 3D surface images in the treatment machine coordinate system. Two simple calibration methods, an analytical solution as three-point matching and a least-squares estimation method as multipoint registration, were introduced to correlate the stereo-vision surface imaging frame with the machine coordinate system. Both types of calibrations utilized 3D surface images of a calibration template placed on the top of the treatment couch. Image transformational parameters were derived from corresponding 3D marked points on the surface images to their given coordinates in the treatment room coordinate system. Our experimental results demonstrated that both methods had provided the desired calibration accuracy of 0.5 mm. The multipoint registration method is more robust particularly for noisy 3D surface images. Both calibration methods have been used as our weekly QA tools for a 3D image-guided radiotherapy system. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4379 / 4383
页数:5
相关论文
共 50 条
  • [31] Innovations in image-guided radiotherapy
    Verellen, Dirk
    De Ridder, Mark
    Linthout, Nadine
    Tournel, Koen
    Soete, Guy
    Storme, Guy
    NATURE REVIEWS CANCER, 2007, 7 (12) : 949 - 960
  • [32] A review of image-guided radiotherapy
    Chen G.T.Y.
    Sharp G.C.
    Mori S.
    Radiological Physics and Technology, 2009, 2 (1) : 1 - 12
  • [33] Implementation of Image-guided Radiotherapy
    Franks, K. N.
    McNair, H. A.
    CLINICAL ONCOLOGY, 2012, 24 (09) : 625 - 626
  • [34] Image-guided Gated Radiotherapy
    Heaton, A.
    Shakeshaft, J.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 268 - 268
  • [35] Innovations in image-guided radiotherapy
    Dirk Verellen
    Mark De Ridder
    Nadine Linthout
    Koen Tournel
    Guy Soete
    Guy Storme
    Nature Reviews Cancer, 2007, 7 : 949 - 960
  • [36] Accurate stereo vision system calibration with chromatic concentric fringe patterns
    An, Shiyong
    Yang, Hongyu
    Zhou, Pei
    Xiao, Wenfan
    Zhu, Jiangping
    Guo, Yanqiong
    APPLIED OPTICS, 2021, 60 (35) : 10954 - 10963
  • [37] A stereo-vision system for support of planetary surface exploration
    Maarten Vergauwen
    Marc Pollefeys
    Luc Van Gool
    Machine Vision and Applications, 2003, 14 : 5 - 14
  • [38] A stereo-vision system for support of planetary surface exploration
    Vergauwen, M
    Pollefeys, M
    Van Gool, L
    MACHINE VISION AND APPLICATIONS, 2003, 14 (01) : 5 - 14
  • [39] Catadioptric stereo-vision system using a spherical mirror
    Barone, S.
    Neri, P.
    Paoli, A.
    Razionale, A. V.
    AIAS2017 - 46TH CONFERENCE ON STRESS ANALYSIS AND MECHANICAL ENGINEERING DESIGN, 2018, 8 : 83 - 91
  • [40] A stereo-vision system to automate the manufacture of a semitrailer chassis
    David Samper
    Jorge Santolaria
    Francisco Javier Brosed
    Juan José Aguilar
    The International Journal of Advanced Manufacturing Technology, 2013, 67 : 2283 - 2292