Accurate calibration of a stereo-vision system in image-guided radiotherapy

被引:9
|
作者
Liu, Dezhi [1 ]
Li, Shidong [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
radiotherapy; patient positioning; stereo-vision; calibration;
D O I
10.1118/1.2362873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image-guided radiotherapy using a three-dimensional (3D) camera as the on-board surface imaging system requires precise and accurate registration of the 3D surface images in the treatment machine coordinate system. Two simple calibration methods, an analytical solution as three-point matching and a least-squares estimation method as multipoint registration, were introduced to correlate the stereo-vision surface imaging frame with the machine coordinate system. Both types of calibrations utilized 3D surface images of a calibration template placed on the top of the treatment couch. Image transformational parameters were derived from corresponding 3D marked points on the surface images to their given coordinates in the treatment room coordinate system. Our experimental results demonstrated that both methods had provided the desired calibration accuracy of 0.5 mm. The multipoint registration method is more robust particularly for noisy 3D surface images. Both calibration methods have been used as our weekly QA tools for a 3D image-guided radiotherapy system. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4379 / 4383
页数:5
相关论文
共 50 条
  • [1] A simple method to calibrate stereo-vision system in image-guided radiotherapy
    Liu, D.
    Li, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2023 - 2023
  • [2] Novel method of calibration with restrictive constraints for stereo-vision system
    Cui, Jiashan
    Huo, Ju
    Yang, Ming
    JOURNAL OF MODERN OPTICS, 2016, 63 (09) : 835 - 846
  • [3] A quick and accurate calibration method for 3D ultrasound in image-guided radiotherapy
    Lachaine, M
    Audet, V
    Huang, X
    Falco, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2154 - 2155
  • [4] A novel registration method for image-guided neurosurgery system based on stereo vision
    An, Yong
    Wang, Manning
    Song, Zhijian
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S967 - S973
  • [6] Pseudo stereo-vision system: A monocular stereo-vision system as a sensor for real-time robot applications
    Pachidis, Theodore P.
    Lygouras, John N.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (06) : 2547 - 2560
  • [7] Fast and accurate vision-based stereo reconstruction and motion estimation for image-guided liver surgery
    Speers, Andrew D.
    Ma, Burton
    Jarnagin, William R.
    Himidan, Sharifa
    Simpson, Amber L.
    Wildes, Richard P.
    HEALTHCARE TECHNOLOGY LETTERS, 2018, 5 (05) : 208 - 214
  • [8] A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
    Bert, C
    Metheany, KG
    Doppke, K
    Chen, GTY
    MEDICAL PHYSICS, 2005, 32 (09) : 2753 - 2762
  • [9] Accurate profile measurement method for industrial stereo-vision systems
    Zhang, Yang
    Liu, Wei
    Lu, Yongkang
    Cheng, Xikang
    Luo, Weiqi
    Di, Hongtu
    Wang, Fuji
    SENSOR REVIEW, 2020, 40 (04) : 445 - 453
  • [10] Image-guided radiotherapy
    de Crevoisier, R.
    Lafond, C.
    Mervoyer, A.
    Hulot, C.
    Jaksic, N.
    Bessieres, I
    Delpon, G.
    CANCER RADIOTHERAPIE, 2022, 26 (1-2): : 34 - 49