Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy

被引:246
|
作者
Marti, CB [1 ]
Gautier, E [1 ]
Wachtl, SW [1 ]
Jakob, RP [1 ]
机构
[1] Hop Cantonal Fribourg, Dept Orthoped, Fribourg, Switzerland
关键词
open-wedge proximal tibial osteotomy; planning osteotomy; posterior tibial slope; knee instability; mechanical axis;
D O I
10.1016/j.arthro.2004.01.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study was performed to determine the accuracy of correction in the frontal plane and to evaluate whether a frontal plane correction influences the sagittal slope of the proximal tibial surface in open-wedge high tibial osteotomy. Type of Study: Retrospective review. Methods: In this study, 30 patients (32 knees) with a mean age of 38 years (range, 20 to 66 years) were available for follow-up evaluation at a minimum interval of 24 months (mean, 42 months; range, 24 to 62 months). A normal axis was planned for a varus morphotype without evidence of osteoarthrosis. If one third of the thickness of the medial cartilage was lost, the new mechanical axis was planned to pass lateral to the center of the knee at the 10% position (where the 0% position is at the center of the knee joint and the 100% position is at the lateral border of the plateau). When two thirds were lost, the new mechanical axis was planned to pass through the 20% position. If total cartilage loss was present, the mechanical axis was planned to pass through the 30% position. The correction was estimated as good when the mechanical axis was found to be approximately +/- 5% of the width of the tibial plateau. The angle of the osteotomy and the size of the wedge-shaped bone graft were calculated using the "push" orthoradiogram. Results: Consolidation of the osteotomy was obtained after a mean period of 8.4 weeks (range, 6 to 13 weeks). The mean amount of valgus correction was 5.9degrees. Sixteen of 32 knees (50%) showed the desired position of the mechanical axis. Ten knees (31%) showed an undercorrection; 6 knees (19%) an overcorrection. The mean increase of the posterior tibial slope was 2.7degrees (range, -8degrees to 10degrees). Conclusions: The medial open-wedge osteotomy of the proximal tibia has a tendency to increase the posterior tibial slope. This effect is unfavorable in anterior knee instability because it increases the anterior translation of the tibia. Increasing the posterior slope can be favorable in posterior instability because it reduces the posterior sag. Level of Evidence: Level IV.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 50 条
  • [41] Open-Wedge High Tibial Osteotomy Using a Protective Cutting System: Technical Advancement for the Accuracy of the Osteotomy and Avoiding Intraoperative Complications
    Lee, Yong Seuk
    Lee, Myung Chul
    Kang, Seo Goo
    Elazab, Ashraf
    Oh, Won Seok
    ARTHROSCOPY TECHNIQUES, 2016, 5 (01): : E7 - E10
  • [42] Control of Posterior Tibial Slope and Patellar Height in Open-Wedge Valgus High Tibial Osteotomy
    Hinterwimmer, Stefan
    Beitzel, Knut
    Paul, Jochen
    Kirchhoff, Chlodwig
    Sauerschnig, Martin
    von Eisenhart-Rothe, Ruediger
    Imhoff, Andreas B.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (04): : 851 - 856
  • [43] The Effect of Hinge Position on Posterior Tibial Slope in Medial Open-Wedge High Tibial Osteotomy
    Moon, Sang Won
    Park, Sin Hyung
    Lee, Byung Hoon
    Oh, Minkyung
    Chang, Minho
    Ahn, Jin Hwan
    Wang, Joon Ho
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (06): : 1128 - 1133
  • [44] A computer simulation study for preserving the tibial posterior slope in open-wedge high tibial osteotomy
    Hanada, Mitsuru
    Hotta, Kensuke
    Matsuyama, Yukihiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (07): : 1285 - 1291
  • [45] Precision of navigated and conventional open-wedge high tibial osteotomy in a cadaver study
    J Lützner
    AF Groß
    KP Günther
    S Kirschner
    European Journal of Medical Research, 15 (3)
  • [46] A computer simulation study for preserving the tibial posterior slope in open-wedge high tibial osteotomy
    Mitsuru Hanada
    Kensuke Hotta
    Yukihiro Matsuyama
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1285 - 1291
  • [47] Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy
    Yong Seuk Lee
    Min Gyu Kim
    Hae Won Byun
    Sang Bum Kim
    Jin Goo Kim
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 846 - 851
  • [48] The effect of frontal plane osteotomy angle on lateral cortex fracture in medial open wedge high tibial osteotomy procedure
    Kirilmaz, Alper
    Ozkaya, Mustafa
    Erdem, Turgut Emre
    Turkmen, Faik
    KNEE, 2025, 52 : 108 - 120
  • [49] Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy
    Dae-Hee Lee
    Sung-Chul Park
    Hyung-Joon Park
    Seung-Beom Han
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3704 - 3712
  • [50] Anterior Open-Wedge Osteotomy to Correct Sagittal and Coronal Malalignment in a Case of Failed High Tibial Osteotomy and Failed Posterior Cruciate Ligament Reconstruction
    Reddy, K. Raghuveer
    Reddy, N. Somasekhara
    Prakash, N.
    ARTHROSCOPY TECHNIQUES, 2024, 13 (09):