IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS

被引:2
|
作者
Giertyas, Cristian J. [1 ]
da Silva, Debora S. [1 ]
da Silva, Camila L. F. [2 ,3 ]
Meneghetti, Mario R. [1 ]
Plentz Meneghetti, Simoni M. [1 ]
de Almeida, Rusiene M. [1 ]
Bortoluzzi, Janaina H. [1 ]
机构
[1] Univ Fed Alagoas, Inst Quim & Biotecnol, BR-57072970 Maceio, AL, Brazil
[2] Secretaria Estadual Educ Estado Parana, BR-80240900 Curitiba, Parana, Brazil
[3] Serv Social Comercio, BR-80240900 Curitiba, Parana, Brazil
来源
QUIMICA NOVA | 2019年 / 42卷 / 07期
关键词
High-performance Liquid Chromatography; ion exchange column; glycerol oxidation; analytical methodologies; identification and quantification; LIQUID-PHASE OXIDATION; SELECTIVE OXIDATION; CATALYTIC-OXIDATION; GOLD CATALYSTS; ACID; AU; MONO; PD;
D O I
10.21577/0100-4042.20170391
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The optimized analytical methodology described herein is based on an ion exchange column and an H3PO4 solution (pH 2.24) as the mobile phase, with a flow rate of 0.4 mL min(-1) and refractive index detection (RID). On applying the methodology, it was possible to identify 7 products obtained from the oxidation of glycerol with an analysis time of 27 min. The developed method was validated through the evaluation of a series of analytical parameters. The results obtained were evaluated considering the peak area and peak height. The analytical curves showed a correlation coefficient of >= 0.986. The coefficient of variation values obtained were <= 3.60% for instrumental precision, <= 19.36% for intermediate precision in LOQ (1.25 mu g mL(-1)) and <= 17.93% for repeatability in LOQ (1.25 mu g mL(-1)) and different days. The limit of quantification established for all compounds was 1.25 mu g mL(-1) obtained through the parameters of the analytical curve. The accuracy of the method showed recovery values of 85.6 to 112.3% for real fortified sample at 3 concentration levels. Two different samples of glycerol oxidation products were applied to the validated methodology; one obtained from AuNP/SiO2 as catalyst (conversion of 62.42%), and other using AuNP/MWCNT (conversion of 89.5%).
引用
收藏
页码:729 / 735
页数:7
相关论文
共 50 条
  • [1] DEVELOPMENT OF AN HPLC METHOD FOR THE DETERMINATION OF GLYCEROL OXIDATION PRODUCTS
    Beltran-Prieto, Juan Carlos
    Pecha, Jiri
    Kasparkova, Vera
    Kolomaznik, Karel
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (19) : 2758 - 2773
  • [2] MODIFICATION OF THE REFRACTIVE INDEX METHOD FOR THE DETECTION OF FOREIGN FATS IN DAIRY PRODUCTS
    BHALERAO, VR
    KUMMEROW, FA
    JOURNAL OF DAIRY SCIENCE, 1956, 39 (07) : 947 - 955
  • [3] Sensitive and selective method for the analysis of menthol from pharmaceutical products by RP-HPLC with refractive index detector
    Shaikh, K. A.
    Patil, Sachin D.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2010, 2 (04): : 360 - 364
  • [4] DETERMINATION OF GLYCOLS BY HPLC WITH REFRACTIVE-INDEX DETECTION
    NITSCHKE, L
    HUBER, L
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (06): : 451 - 453
  • [5] Stability-Indicating HPLC Method for the Determination of Impurities in Meprobamate with Refractive Index Detection
    Karthikeyan, K.
    Balaji, T. S.
    Shanmugasundaram, P.
    Pillai, K. Chandrasekara
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (03) : 212 - 218
  • [6] A Method of the Detection of Marine Pollution Based on the Measurement of Refractive Index
    Shi, Qing-guo
    Ying, Lu-na
    Wang, Lu
    Peng, Bao-jIn
    Ying, Chao-fu
    Design, Manufacturing and Mechatronics, 2014, 551 : 347 - 352
  • [7] Analysis of vitamin E and its oxidation products by HPLC with electrochemical detection
    Yamauchi, R
    Noro, H
    Shimoyamada, M
    Kato, K
    LIPIDS, 2002, 37 (05) : 515 - 522
  • [8] A fluorescence detection HPLC method for the analysis of aluminum in pharmaceutical products
    Nagae, N
    Sato, M
    AMERICAN LABORATORY, 2005, 37 (13) : 19 - +
  • [9] Critical analytical review: Rare and recent applications of refractive index detector in HPLC chromatographic drug analysis
    Al-Sanea, Mohammad M.
    Gamal, Mohammed
    MICROCHEMICAL JOURNAL, 2022, 178
  • [10] Method for refractive index detection for emulsion concentration
    Zhao, Sihai
    Han, Ke
    Yuan, Gaopeng
    Wang, Lin
    FUNCTIONAL MATERIALS, 2018, 25 (02): : 401 - 405