The optimized match method enhances the energy efficiency ratio (EER) of room air-conditioner

被引:0
|
作者
Wang Zhiyuan [1 ]
Hetao [1 ]
Xu Zhiliang [1 ]
Luohao [1 ]
Dang Hongchang [2 ]
机构
[1] Henan Univ Sci & Technol, Coll Vehicle & Power, Luoyang, Peoples R China
[2] Anhui Ind Univ, Maanshan, Peoples R China
关键词
air-conditioner; System; Optimization; EER; HEAT-TRANSFER; CONDENSATION; TUBES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, an experimental study was conducted on domestic air- conditioner refrigeration system to increase the system energy efficiency ratio (EER). First, different types of high efficiency compressors were tested and selected. Second, inner-grooved copper tubes which had fins with hydrophilic membrane, together with the indoor and outdoor helical fans were employed to improve the heat convection efficiency. Third, the relationship between capillary's optimum length and refrigerant charge quantity was confirmed experimentally. By these means, the system EER can reach up to 3.2, which meets the demands of National standards of China.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] ROOM AIR-CONDITIONER FOR TROPICAL USE
    WATANABE, O
    TAJIMA, M
    NIGO, T
    TOSHIBA REVIEW, 1979, (119): : 31 - 34
  • [2] EXAMINATION OF SEASONAL ENERGY EFFICIENCY RATIO AND ECONOMICAL ANALYSIS OF ROOM AIR CONDITIONER
    Zhang Furen
    Zeng Xiaoyan
    Zhang Hui
    PROCEEDINGS OF THE 2010 INTERNATIONAL CONFERENCE ON MECHANICAL, INDUSTRIAL, AND MANUFACTURING TECHNOLOGIES (MIMT 2010), 2010, : 79 - 84
  • [3] High-efficiency thermoelectric air-conditioner
    Wang, Tie-min
    Zhang, Jian-zhong
    Ma, Hong-kui
    HIGH-PERFORMANCE CERAMICS IV, PTS 1-3, 2007, 336-338 : 888 - +
  • [4] A novel system of the isothermal dehumidification in a room air-conditioner
    Han, Xing
    Zhang, Xu
    Wang, Lihui
    Niu, Runping
    ENERGY AND BUILDINGS, 2013, 57 : 14 - 19
  • [5] PAPER YOUR LIVING-ROOM WITH AN AIR-CONDITIONER
    BEARD, J
    NEW SCIENTIST, 1994, 144 (1947) : 22 - 22
  • [6] Limiting the impact of increasing cooling demand in the European union: Results from a study on room air-conditioner energy efficiency
    Adnot, Jérôme
    Orphelin, Matthieu
    Lopes, Carlos
    Waide, Paul
    Proceedings ACEEE Summer Study on Energy Efficiency in Buildings, 2000, 10 : 1 - 10
  • [7] Residential air-conditioner usage in China and efficiency standardization
    Wu, Jianghong
    Liu, Chaopeng
    Li, Hongqi
    Ouyang, Dong
    Cheng, Jianhong
    Wang, Yuanxia
    You, Shaofang
    ENERGY, 2017, 119 : 1036 - 1046
  • [8] A QUESTION OF CONTROL - ALTERNATIVE PATTERNS OF ROOM AIR-CONDITIONER USE
    LUTZENHISER, L
    ENERGY AND BUILDINGS, 1992, 18 (3-4) : 193 - 200
  • [9] SYMPOSIUM - COMPUTER - ENGINEERING TOOL FOR ROOM AIR-CONDITIONER DESIGN
    RIVARD, FL
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1972, 14 (12): : 43 - &
  • [10] A Novel Window Type Air-conditioner with Energy Recovering
    Luo, Qinghai
    Zhang, Pengfei
    Yang, Xiufei
    Zou, Jun
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3021 - 3024