IMPACT OF SWIRL FLOW ON THE COOLING PERFORMANCE OF AN EFFUSION COOLED COMBUSTOR LINER

被引:0
|
作者
Wurm, B. [1 ]
Schulz, A. [1 ]
Bauer, H. -J. [1 ]
Gerendas, M. [2 ]
机构
[1] KIT, Inst Therm Stroemungsmaschinen, D-76131 Karlsruhe, Germany
[2] RollsRoyce Deutschland Ltd & Co KG, Combustor Aerothermal & Cooling, D-15827 Blankenfelde Mahlow, Germany
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An experimental study on combustor liner cooling of modern direct lean injection (DLI) combustion chambers using coolant ejection from both effusion cooling holes and a starter film has been conducted. The experimental setup consists of a generic scaled three sector planar rig in an open loop hot gas wind tunnel, which has been described earlier in Wunn et al. [1]. Experiments are performed without combustion. Realistic engine conditions are achieved by applying engine-realistic Reynolds numbers, Mach numbers, and density ratios. A Particle Image Velocimetry (PIV) measurement technique is employed, which has been adjusted to allow for high resolution near wall velocity measurements with and without coolant ejection. As the main focus of the present study is a deeper understanding of the interaction of swirl flows and near wall cooling flows, wall pressure measurements are performed for the definition of local blowing ratios and to identify the impact on the local cooling performance. For thermal investigations an infrared thennography measurement technique is employed that allows high resolution thermal studies on the effusion cooled liner surface. The effects of different heat shield geometry on the flow field and performance of the cooling films are investigated in terms of near wall velocity distributions and film cooling effectiveness. Two different heat shield configurations are investigated which differ in shape and inclination angle of the so called heat shield lip. Operating conditions for the hot gas main flow are kept constant. The pressure drop across the effusion cooled liner is varied between 1% and 3% of the total pressure. Results show the impact of the swirled main flow on the stability of the starter film and on the effusion cooling performance. Stagnation areas which could be identified by wall pressure measurements are confirmed by PIV measurements. Thermal investigations reveal reduced cooling performance in the respective stagnation areas.
引用
收藏
页码:1027 / +
页数:2
相关论文
共 50 条
  • [31] Effect of Spanwise Hole-to-Hole Spacing on Overall Cooling Effectiveness of Effusion Cooled Combustor Liners for a Swirl-Stabilized Can Combustor
    Ahmed, Shoaib
    Wahls, Benjamin H.
    Ekkad, Srinath V.
    Lee, Hanjie
    Ho, Yin-Hsiang
    Journal of Turbomachinery, 2022, 144 (07):
  • [32] Effect of Spanwise Hole-to-Hole Spacing on Overall Cooling Effectiveness of Effusion Cooled Combustor Liners for a Swirl-Stabilized Can Combustor
    Ahmed, Shoaib
    Wahls, Benjamin H.
    Ekkad, Srinath V.
    Lee, Hanjie
    Ho, Yin-Hsiang
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2022, 144 (07):
  • [33] APPLICATION OF UNCERTAINTY QUANTIFICATION METHODS TO THE PREDICTION OF EFFUSION COOLED COMBUSTOR LINER TEMPERATURE
    Gamannossi, Andrea
    Amerini, Alberto
    Poggiali, Matteo
    Elmi, Carlo Alberto
    Mazzei, Lorenzo
    Andreini, Antonio
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 7A, 2020,
  • [34] Experimental and numerical investigation of swirling flow on the conjugate cooling efficiency of an effusion-cooled combustor
    Dong, Gengyi
    Liu, Yingjie
    Wang, Min
    Zhang, Jingyu
    He, Xiaomin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 198
  • [35] COMBINED EFFECT OF SLOT INJECTION, EFFUSION ARRAY AND DILUTION HOLE ON THE COOLING PERFORMANCE OF A REAL COMBUSTOR LINER
    Ceccherini, Alberto
    Facchini, Bruno
    Tarchi, Lorenzo
    Toni, Lorenzo
    Coutandin, Daniele
    PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, 2009, : 1431 - 1440
  • [36] EFFUSION-COOLING PERFORMANCE AT GAS TURBINE COMBUSTOR REPRESENTATIVE FLOW CONDITIONS
    Kakade, Vinod U.
    Thorpe, Steven J.
    Gerendas, Miklos
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 4, PTS A AND B, 2012, : 857 - +
  • [37] Effects of wall cooling with microchannels on swirl combustor performance
    Huang, Yue
    Feng, Xinchi
    Lin, Zhiwei
    You, Yancheng
    AEROSPACE SCIENCE AND TECHNOLOGY, 2020, 106 (106)
  • [38] EXPERIMENTAL STUDY ON OVERALL COOLING EFFECTIVENESS OF SWIRL-STABILIZED MODEL COMBUSTOR WITH EFFUSION COOLING
    Ji, Yongbin
    Zhang, Liang
    Jin, Ming
    Ge, Bing
    Zang, Shusheng
    Xin, Jianhua
    Wu, Weiliang
    Li, Mingjia
    Xu, Wenyan
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 5A, 2019,
  • [39] EXPERIMENTAL AND NUMERICAL STUDY ON EFFUSION COOLING CONFIGURATION FOR THE SWIRL CMC COMBUSTOR PLATFORM
    Du, Kun
    Chen, Qihao
    Liang, Tingrui
    Jia, Yihao
    Liu, Cunliang
    PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 6A, 2022,
  • [40] Multi-fidelity modelling of an impingement/effusion cooled gas turbine combustor liner
    Yoko, M. J.
    Sun, X.
    van der Spuy, S. J.
    Sethi, V
    APPLIED THERMAL ENGINEERING, 2021, 185