RF synchronized injection from SPring-8 Linac to NewSUBARU storage ring

被引:0
|
作者
Shoji, Y [1 ]
Hisao, S [1 ]
Matsubara, T [1 ]
Asaka, T [1 ]
Suzuki, S [1 ]
Kawashima, Y [1 ]
机构
[1] Himeji Inst Technol, LASTI, New SUBARU SPring 8, Kamigori, Hyogo 6781205, Japan
来源
SYNCHROTRON RADIATION INSTRUMENTATION | 2004年 / 705卷
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper confirms the occurrence of RF synchronized injection from SPring-8 Linac to the NewSUBARU storage ring. NewSUBARU is a 1.5 GeV storage ring with injection energy of 1.0 GeV. Besides the 1.5 GeV user mode, the ring is often operated at 1.0 GeV for EUV users with the so-called top-up injection mode. In this experiment, we use a new synchronization method developed at SPring-8, wherein an instantaneous synchronization between NewSUBARU RF (500 MHz) and Linac RF (2856 MHz) enables a buckets-to-bucket beam transfer. This is one of the key technologies of top-up operations in a storage ring that uses a linac as an injector. The RF clock and timing trigger signal are sent to the Linac from NewSUBARU, and this clock is used to delay units in order to maintain good synchronicity. This works as a standard because it has a system to compensate for transfer-time drift. The arbitrary waveform generator is another key module. It produces a clock 1/32 of that of the Linac RF using the NewSUBARU RF clock. With this system, we eliminated beam loss at the injection due to spillage from the ring RF bucket.
引用
收藏
页码:53 / 56
页数:4
相关论文
共 50 条
  • [31] Suppression of the coupled-bunch instability in the SPring-8 storage ring
    Ego, H
    Hara, M
    Kawashima, Y
    Ohashi, Y
    Ohshima, T
    Suzuki, H
    Takeshita, I
    Yonehara, H
    TOWARDS X-RAY FREE ELECTRON LASERS: WORKSHOP ON SINGLE PASS, HIGH GAIN FELS STARTING FROM NOISE, AIMING AT COHERENT X-RAYS, 1997, (413): : 267 - 275
  • [32] Analysis of positron focusing section for SPring-8 Linac
    Mizuno, A
    Suzuki, S
    Yoshikawa, H
    Hori, T
    Yanagida, K
    Sakaki, H
    Taniuchi, T
    Kotaki, H
    Yokomizo, H
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1046 - 1048
  • [33] Fast beam current monitor for SPring-8 linac
    Yanagida, K
    Yoshikawa, H
    Suzuki, S
    Mizuno, A
    Sasaki, H
    Taniuchi, T
    Hori, T
    Kobayashi, T
    Asaka, T
    Yokomizo, H
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 765 - 768
  • [34] Toward single pass FEL with SPring-8 linac
    Yokomizo, H
    X-RAY LASERS 1998, 1999, 159 : 547 - 551
  • [35] Bunch compression at the SPring-8 linac and successive generation of THz pulse train in the isochronous ring
    Shoji, Yoshihiko
    Asaka, Takao
    Dewa, Hideki
    Hanaki, Hirohumi
    Hisaoka, Yoshinori
    Kobayashi, Toshiaki
    Matsubara, Takahiro
    Mitsui, Takayuki
    Mizuno, Akihiko
    Suzuki, Shinsuke
    Taniuchi, Tsutomu
    Tomizawa, Hiromitsu
    Yanagida, Kenichi
    INFRARED PHYSICS & TECHNOLOGY, 2008, 51 (05) : 394 - 396
  • [36] LUMPED NEG PUMP FOR CROTCH AND PUMPING SYSTEM OF SPRING-8 STORAGE RING
    SAKAUE, HA
    HIRANO, Y
    IN, SR
    YOKOUCHI, S
    WATANABE, K
    BE, SH
    VACUUM, 1993, 44 (5-7) : 523 - 526
  • [37] Beam based calibration of BPM position sensitivity at SPring-8 storage ring
    Sasaki, S
    Soutome, K
    Tanaka, H
    BEAM INSTRUMENTATION WORKSHOP 2002, 2002, 648 : 425 - 432
  • [38] Design of automatic beam transport system at SPring-8 LINAC
    Sakaki, H
    Yoshikawa, H
    Yokomizo, H
    Sogo, T
    Kinoshita, K
    Adachi, N
    ACCELERATOR AND LARGE EXPERIMENTAL PHYSICS CONTROL SYSTEMS, 1997, : 509 - 511
  • [39] Method for stabilizing beam intensity and energy in the SPring-8 linac
    Asaka, T
    Kawashima, Y
    Takashima, T
    Kobayashi, T
    Ohshima, T
    Hanaki, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (2-3): : 249 - 269
  • [40] Bunch compression and beam transport for SPring-8 linac SASE
    Yanagida, K
    Suzuki, S
    Taniuchi, T
    Yoshikawa, H
    Mizuno, A
    Abe, H
    Hori, T
    Sakaki, H
    Asaka, T
    Yokomizo, H
    TOWARDS X-RAY FREE ELECTRON LASERS: WORKSHOP ON SINGLE PASS, HIGH GAIN FELS STARTING FROM NOISE, AIMING AT COHERENT X-RAYS, 1997, (413): : 299 - 305