Energy, exergy, and economic analysis of single and double effect LiBr-H2O absorption chillers

被引:76
|
作者
Avanessian, T. [1 ,2 ]
Ameri, M. [1 ,2 ]
机构
[1] Shahid Bahonar Univ, Fac Engn, Dept Mech Engn, Kerman, Iran
[2] Shahid Bahonar Univ, Energy & Environm Engn Res Ctr, Kerman, Iran
关键词
Absorption refrigeration system; Counter-flow wet cooling tower; Boiler; Exergy; Second law efficiency; WATER; PERFORMANCE; SYSTEM;
D O I
10.1016/j.enbuild.2014.01.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study different water-cooled LiBr-H2O absorption systems under different operating and climatic conditions are analyzed and compared, and the effect of considering the chemical exergy of the LiBr-H2O solution on the second law analysis of such systems is probed as well. Results show that the EUF increases with increasing the generator and evaporator temperatures and decreases with the increase in the temperature and relative humidity of the ambient air. The total exergy efficiency increases with increasing the generator or ambient air temperature, decreases with increasing the evaporator temperature, and changes slightly with relative humidity. In T-amb =35 C and phi = 30%, the system including direct-fired double-effect chiller has a EUF = 1.20 and psi = 7.86% both of which are respectively 11% and 82% higher than the systems including hot-water double-effect and single-effect chillers. The economic analysis reveals that for the operating conditions presented here, the single-effect system is uneconomical and the payback period in the case of utilizing the direct-fired double-effect chiller instead of the hot-water one is about 3.5 years. Finally, the CO2 emission of the single-effect system is respectively about 1.9 and 1.7 times higher than direct-fired and hot-water double-effect ones. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 36
页数:11
相关论文
共 50 条
  • [21] Performance Enhancement in LiCl-H2O and LiBr-H2O Absorption Cooling Systems Through an Advanced Exergy Analysis
    Mody, Parth
    Patel, Jatin
    Modi, Nishant
    Pandya, Bhargav
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (01)
  • [22] Performance prediction of a solar/gas driving double effect LiBr-H2O absorption system
    Liu, YL
    Wang, RZ
    RENEWABLE ENERGY, 2004, 29 (10) : 1677 - 1695
  • [23] Solution Crystallization Detection for double-effect LiBr-H2O steam absorption chiller
    Gilani, Syed Ihtsham-ul-Haq
    Ahmed, Mojahid Sidahmed Mohammed Salih
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1522 - 1528
  • [24] Analysis of the minimum activation temperature of LiBr-H2O absorption chiller
    Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200240, China
    Kung Cheng Je Wu Li Hsueh Pao, 2013, 11 (2020-2024):
  • [25] ENERGY AND EXERGY ANALYSES OF A LIBR-H2O SOLAR ABSORPTION COOLING SYSTEM: A CASE STUDY FOR BRAZILIAN PUBLIC BUILDINGS
    Pinto, Gabriel
    de Souza, Tulio
    Coronado, Christian
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2022, 21 (06): : 939 - 950
  • [26] A mathematical model with experiments of single effect absorption heat pump using LiBr-H2O
    Sun, Jian
    Fu, Lin
    Zhang, Shigang
    Hou, Wei
    APPLIED THERMAL ENGINEERING, 2010, 30 (17-18) : 2753 - 2762
  • [27] Modeling and Active Disturbance Rejection Control of a Single Effect LiBr-H2O Absorption Chiller
    He, Ting
    Li, Donghai
    Wu, Zhenlong
    Xue, Yali
    Yang, Yuxin
    2017 11TH ASIAN CONTROL CONFERENCE (ASCC), 2017, : 2726 - 2731
  • [28] Experimental characterization of a single stage LiBr-H2O absorption test rig
    Gutierrez, G.
    Venegas, M.
    Rodriguez Aumente, P.
    Izquierdo Millan, M.
    Lecuona Neumann, A.
    ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 1311 - +
  • [29] Stationary analysis of a solar LiBr-H2O absorption refrigeration system
    Monne, C.
    Alonso, S.
    Palacin, F.
    Guallar, J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02): : 518 - 526
  • [30] LiBr-H2O absorption heat pump for single-effect evaporation desalination process
    Mandani, F
    Ettouney, H
    El-Dessouky, H
    DESALINATION, 2000, 128 (02) : 161 - 176