Left ventricular mass assessed by three-dimensional echocardiography using rotational acquisition

被引:9
|
作者
Rodevand, O [1 ]
Bjornerheim, R [1 ]
Kolbjornsen, O [1 ]
Ihlen, H [1 ]
Kjekshus, J [1 ]
机构
[1] UNIV OSLO,RIKSHOSP,NATL HOSP,CTR CLIN EPIDEMIOL & STAT,N-0027 OSLO,NORWAY
关键词
three-dimensional ultrasound; echocardiography; three-dimensional reconstructions; left ventricular mass;
D O I
10.1002/clc.4960201111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The reproducibility of left ventricular (LV) mass measurement by two-dimensional (2-D) echocardiography is inadequate for individual assessments. Hypothesis: This study was undertaken to evaluate the potential of LV mass determination with a new three-dimensional (3-D) echocardiographic method compared with 2-D measurements. Methods: Pot-cine agarose-filled left ventricles (n = 15, true mass 61-511 g) of different shapes were measured by a multiplane 3-D method based on 90 images acquired by probe rotation axis (1) perpendicular and (2) parallel to the ventricular long axis [''parasternal'' (the left sternal border was not present as a reference point in this study) and apical views]. Mass was also obtained using (3) the biplane truncated ellipsoid and (4) area-length methods, as well as (5) the modified cube formula. Five hearts were not analyzed with the apical 3-D technique because of insufficient image quality. Results: Systematic deviation from true mass was small with all methods (<5.3%). Accuracy, expressed as 1 standard deviation of individual estimates around this systematic bias, was 7.7, 13.6, 8.2, 11.9, and 11.9% of true mass for the methods 1-5, respectively. Interobserver reproducibility, expressed as the coefficient of variation, was 4.7, 8.8, 8.1, 8.9, and 9.4% for the same methods. Conclusion: Limits fur individual accuracy and reproducibility of LV mass estimates are nearly doubled using apical compared with ''parasternal'' 3-D echocardiography in vitro. A main advantage of ''parasternal'' 3-D compared with 2-D LV mass estimates is better reproducibility, but at the expense of greater time consumption. Apical 3-D technique is not superior to simpler 2-D methods based on ''parasternal'' short axis imaging.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 50 条
  • [41] Validation of live three-dimensional echocardiography for quantification of absolute left ventricular volumes; comparison with volumetric three-dimensional echocardiography
    Shin, JH
    Shiota, T
    Qin, JX
    Agler, DA
    Saracino, G
    Greenberg, N
    Oryszak, S
    Thomas, JD
    EUROPEAN HEART JOURNAL, 2004, 25 : 260 - 260
  • [42] Prognostic value of the left ventricular-left atrial volume ratio assessed using three-dimensional echocardiography with fully automated analytical software
    Takeuchi, Masaaki
    Nabeshima, Yosuke
    Kitano, Tetsuji
    Negishi, Kazuaki
    JOURNAL OF CARDIOLOGY, 2021, 78 (05) : 406 - 412
  • [43] Determination of left ventricular mass by real-time three-dimensional echocardiography: In vitro validation
    Takuma, S
    Cabreriza, SE
    Sciacca, R
    Di Tullio, MR
    Spotnitz, HM
    Homma, S
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (07): : 665 - 674
  • [44] Left ventricular mass measured by myocardial perfusion gated SPECT - Relation to three-dimensional echocardiography
    Akinboboye, O
    Germano, G
    Idris, O
    Nichols, K
    Gopal, A
    Berman, D
    Bergmann, SR
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (05) : 392 - 397
  • [45] Three-dimensional echocardiography: Precision and accuracy of left ventricular volume measurement using rotational geometry with variable numbers of slice resolution
    Tanabe, K
    Belohlavek, M
    Jakrapanichakul, D
    Bae, RY
    Greenleaf, JF
    Seward, JB
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (06): : 575 - 580
  • [46] Three-Dimensional Speckle Tracking Echocardiography for Evaluating Left Ventricular Rotation: An in vitro Validation Study using a Rotational Phantom Model
    Park, Austin
    Zhu, Meihua
    Kimura, Sumito
    Bleck, Rosie
    Amacher, Kacie
    Streiff, Cole
    Ravi, Sreyas
    Ashraf, Shahryar
    Ashraf, Muhammad
    Sahn, David J.
    CIRCULATION, 2013, 128 (22)
  • [47] Intervendor Consistency and Accuracy of Left Ventricular Volume Measurements Using Three-Dimensional Echocardiography
    Muraru, Denisa
    Cecchetto, Antonella
    Cucchini, Umberto
    Zhou, Xiao
    Lang, Roberto M.
    Romeo, Gabriella
    Vannan, Mani
    Mihaila, Sorina
    Miglioranza, Marcelo Haertel
    Iliceto, Sabino
    Badano, Luigi P.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2018, 31 (02) : 158 - +
  • [48] Evaluation of left ventricular volumes in the early neonatal period using three-dimensional echocardiography
    Nagasawa, Hiroyuki
    CARDIOLOGY IN THE YOUNG, 2014, 24 (04) : 685 - 693
  • [49] Intervendor consistency and accuracy of left ventricular volume measurements using three-dimensional echocardiography
    Cecchetto, A.
    Muraru, D.
    Marra, M. Perazzolo
    Cucchini, U.
    Romeo, G.
    Zhou, X.
    Mihaila, S.
    Iliceto, S.
    Lang, R. M.
    Badano, L. P.
    EUROPEAN HEART JOURNAL, 2014, 35 : 286 - 286
  • [50] Sources of variation and bias in assessing left ventricular dyssynchrony using three-dimensional echocardiography
    Muraru, D.
    Badano, L. P.
    Gianfagna, P.
    Ermacora, D.
    Proclemer, A.
    EUROPEAN HEART JOURNAL, 2010, 31 : 876 - 876