Determination of nonlinear refractive index by an iterative phase retrieval method

被引:0
|
作者
Yazdani, Roghayeh [1 ]
Fallah, Hamidreza [1 ,2 ]
机构
[1] Univ Isfahan, Dept Phys, Esfahan 8174673441, Iran
[2] Univ Isfahan, Quantum Opt Res Grp, Dept Phys, Esfahan 8174673441, Iran
关键词
We present a simple and robust technique for measuring the nonlinear refractive index. The principle is based on an iterative phase retrieval algorithm with a pump–probe system. Different strong phase modulations are intentionally introduced into the probe beam; and corresponding diffraction intensity patterns are recorded. The recordings are used in the phase retrieval algorithm to reconstruct the pump-induced phase on the probe beam. The nonlinear refractive index is then extracted from the reconstructed phase. The reconstruction method offers a straightforward procedure and a simple lensless setup. Simulations validate the proposed method. The effects of different characteristics of the pump and probe beams on the quality of reconstructions are investigated. The obtained results demonstrate that the reconstructions are accurate even for the probe beams with complex-valued fields and non-Gaussian pump beams; it removes the requirement for smooth fields of the pump and probe beams. The validity of the method in noisy conditions is also shown. © 2020 Optical Society of America;
D O I
10.1364/AO.408473
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a simple and robust technique for measuring the nonlinear refractive index. The principle is based on an iterative phase retrieval algorithm with a pump-probe system. Different strong phase modulations are intentionally introduced into the probe beam, and corresponding diffraction intensity patterns are recorded. The recordings are used in the phase retrieval algorithm to reconstruct the pump-induced phase on the probe beam. The nonlinear refractive index is then extracted from the reconstructed phase. The reconstruction method offers a straightforward procedure and a simple lensless setup. Simulations validate the proposed method. The effects of different characteristics of the pump and probe beams on the quality of reconstructions are investigated. The obtained results demonstrate that the reconstructions are accurate even for the probe beams with complex-valued fields and non-Gaussian pump beams; it removes the requirement for smooth fields of the pump and probe beams. The validity of the method in noisy conditions is also shown. (C) 2020 Optical Society of America
引用
收藏
页码:10618 / 10625
页数:8
相关论文
共 50 条
  • [32] Determination of Refractive Index of Softwood Using Immersion Liquid Method
    Juttula, Harri
    Makynen, Anssi J.
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1231 - 1234
  • [33] DETERMINATION OF THE REFRACTIVE-INDEX OF TRANSPARENT MEDIA BY A DIFFRACTION METHOD
    AREFEV, AA
    STAROSTENKO, BV
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (05): : 394 - 396
  • [34] Refractive index determination by the immersion method in industrial and research laboratories
    Cooke, PM
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A731 - A731
  • [35] The influence of absorption on the refractive index determination by the minimum deviation method
    Zhang, Qiuzhang
    Luo, Tianshu
    OPTIK, 2020, 223
  • [36] An acoustic method for determination of the effective temperature and refractive index of air
    Lassila, A
    Korpelainen, V
    RECENT DEVELOPMENTS IN TRACEABLE DIMENSIONAL MEASUREMENTS II, 2003, 5190 : 316 - 326
  • [37] Determination of the refractive index of calcium nitrate measured by the extension method
    Park, Jiweon
    Kim, Ha Eun
    Shin, Jun
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [38] Determination of the refractive index of adipic acid measured by extension method
    Um, Brian
    Shin, Hyo Jung
    Shin, Jun
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [40] Analysis of method of determination of refractive index and Abbe number of lens
    Smejkal, Michal
    Smejkal, Filip
    Miks, Antonin
    Novak, Jiri
    Novak, Pavel
    Pokorny, Petr
    OPTICAL FABRICATION, TESTING, AND METROLOGY VI, 2018, 10692