Comparison of the Conventional and Electroenhanced Direct-Immersion Solid-Phase Microextraction for Sampling of Nicotine in Biological Fluids of the Human Body

被引:7
|
作者
Abdolhosseini, Sana [1 ]
Ghiasvand, Ali Reza [1 ]
Heidari, Nahid [1 ]
机构
[1] Lorestan Univ, Dept Chem, POB 465, Khorramabad 4431668151, Iran
来源
MOLECULES | 2018年 / 23卷 / 05期
关键词
direct-immersion SPME; electroenhanced SPME; nicotine; plasma; urine; LIQUID-CHROMATOGRAPHY; NANOSTRUCTURED POLYPYRROLE; EXTRACTION; HEADSPACE; FIBER; URINE; COATINGS; COMPOSITE; ALKALOIDS; COTININE;
D O I
10.3390/molecules23051171
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A stainless steel fiber was made porous and adhesive by platinization and then coated by nanostructured polypyrrole (PPy), using an appropriate electrophoretic deposition (EPD) method. The morphological surface structure and functional groups of the PPy-coated fiber were studied using SEM (Scanning electron microscope) instrument. The prepared fiber was used for comparison of direct immersion (DI) and electroenhanced direct immersion solid-phase microextraction (EE-DI-SPME) of nicotine in human plasma and urine samples followed by gas chromatography flame ionization detector (GC-FID) determination. The effects of the influential experimental parameters on the efficiency of the DI-SPME and EE-DI-SPME methods, including the pH and ionic strength of the sample solution, applied Direct current (DC) voltage, extraction temperature and time and stirring rate, were optimized. Under the optimal conditions, the calibration curves for the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were linear over the ranges of 0.1-10.0 g mL(-1) and 0.001-10.0 g mL(-1), respectively. The relative standard deviations (RSDs, n = 6) were found to be 6.1% and 4.6% for the DI and EE strategies, respectively. The LODs (limit of detection) of the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were found to be 10 and 0.3 ng mL(-1), respectively. The relative recovery values (for the analysis of 1 mu g mL(-1) nicotine) were found to be 91-110% for EE-DI-SPME and 75-105% for DI-SPME. The enrichment factors for DI-SPME and EE-DI-SPME sampling were obtained as 38,734 and 50,597, respectively. The results indicated that EE-SPME was more efficient for quantitation of nicotine in biological fluids. The developed procedure was successfully carried out for the extraction and measurement of nicotine in real plasma and urine samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Improved extraction of ethanol from human body fluids by headspace solid-phase microextraction with a Carboxen-polydimethylsiloxane-coated fiber
    Department of Legal Medicine, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8555, Japan
    Chromatographia, 9-10 (593-595):
  • [42] Improved extraction of ethanol from human body fluids by headspace solid-phase microextraction with a carboxen-polydimethylsiloxane-coated fiber
    X. -P. Lee
    T. Kumazawa
    K. Sato
    H. Seno
    A. Ishii
    O. Suzuki
    Chromatographia, 1998, 47 : 593 - 595
  • [43] Improved extraction of ethanol from human body fluids by headspace solid-phase microextraction with a carboxen-polydimethylsiloxane-coated fiber
    Lee, XP
    Kumazawa, T
    Sato, K
    Seno, H
    Ishii, A
    Suzuki, O
    CHROMATOGRAPHIA, 1998, 47 (9-10) : 593 - 595
  • [44] Simultaneous determination of selegiline and desmethylselegiline in human body fluids by headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Kuriki, Ayako
    Kumazawa, Takeshi
    Lee, Xiao-Pen
    Hasegawa, Chika
    Kawamura, Mitsuru
    Suzuki, Osamu
    Sato, Keizo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (02): : 283 - 291
  • [45] Comparison of headspace solid-phase microextraction with conventional extraction for the analysis of the volatile components in Melia azedarach
    Yang, Yanqin
    Xiao, Yanmeng
    Liu, Baofeng
    Fang, Xuexun
    Yang, Wei
    Xu, Jingwei
    TALANTA, 2011, 86 : 356 - 361
  • [46] Effect of Binding Components in Complex Sample Matrices on Recovery in Direct Immersion Solid-Phase Microextraction: Friends or Foe?
    Alam, Md. Nazmul
    Pawliszyn, Janusz
    ANALYTICAL CHEMISTRY, 2018, 90 (04) : 2430 - 2433
  • [47] On-fiber derivatization for direct immersion solid-phase microextraction Part I: Acylation of amphetamine with pentafluorobenzoyl chloride
    Koster, EHM
    Bruins, CHP
    Wemes, C
    de Jong, GJ
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (02): : 116 - 122
  • [48] Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography
    Lee, Xiao-Pen
    Kumazawa, Takeshi
    Kondo, Kei
    Sato, Keizo
    Suzuki, Osamu
    Journal of Chromatography B, 1999, 734 (01): : 155 - 162
  • [49] Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography
    Lee, XP
    Kumazawa, T
    Kondo, K
    Sato, K
    Suzuki, O
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 734 (01): : 155 - 162
  • [50] Fiber coating based on a green metal-organic framework to determine phthalates in bottled waters by direct-immersion micro solid-phase extraction
    Rascon, Andres J.
    Rocio-Bautista, Priscilla
    Moreno-Gonzalez, David
    Garcia-Reyes, Juan F.
    Ballesteros, Evaristo
    MICROCHEMICAL JOURNAL, 2023, 191