Validation of the angular measurements of a new inertial-measurement-unit based rehabilitation system: comparison with state-of-the-art gait analysis

被引:67
|
作者
Leardini, Alberto [1 ]
Lullini, Giada [1 ]
Giannini, Sandro [1 ]
Berti, Lisa [1 ]
Ortolani, Maurizio [1 ]
Caravaggi, Paolo [1 ]
机构
[1] Ist Ortoped Rizzoli, Movement Anal Lab, Bologna, Italy
关键词
Inertial measurement unit; Gait analysis; Rehabilitation; Knee; Hip; Thorax; Joint flexion; Audio-visual bio-feedback; Video-games; JOINT ANGLE MEASUREMENT; KINEMATICS; MOTION; SENSORS; BIOFEEDBACK; OUTCOMES; GAMES;
D O I
10.1186/1743-0003-11-136
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Several rehabilitation systems based on inertial measurement units (IMU) are entering the market for the control of exercises and to measure performance progression, particularly for recovery after lower limb orthopaedic treatments. IMU are easy to wear also by the patient alone, but the extent to which IMU's malpositioning in routine use can affect the accuracy of the measurements is not known. A new such system (Riablo (TM), CoRehab, Trento, Italy), using audio-visual biofeedback based on videogames, was assessed against state-of-the-art gait analysis as the gold standard. Methods: The sensitivity of the system to errors in the IMU's position and orientation was measured in 5 healthy subjects performing two hip joint motion exercises. Root mean square deviation was used to assess differences in the system's kinematic output between the erroneous and correct IMU position and orientation. In order to estimate the system's accuracy, thorax and knee joint motion of 17 healthy subjects were tracked during the execution of standard rehabilitation tasks and compared with the corresponding measurements obtained with an established gait protocol using stereophotogrammetry. Results: A maximum mean error of 3.1 +/- 1.8 deg and 1.9 +/- 0.8 deg from the angle trajectory with correct IMU position was recorded respectively in the medio-lateral malposition and frontal-plane misalignment tests. Across the standard rehabilitation tasks, the mean distance between the IMU and gait analysis systems was on average smaller than 5 degrees. Conclusions: These findings showed that the tested IMU based system has the necessary accuracy to be safely utilized in rehabilitation programs after orthopaedic treatments of the lower limb.
引用
收藏
页数:7
相关论文
共 49 条
  • [21] A state-based, proportional myoelectric control method: online validation and comparison with the clinical state-of-the-art
    Jiang, Ning
    Lorrain, Thomas
    Farina, Dario
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11 : 110
  • [22] Validation of Alogo Move Pro: A GPS-Based Inertial Measurement Unit for the Objective Examination of Gait and Jumping in Horses
    Guyard, Kevin Cedric
    Montavon, Stephane
    Bertolaccini, Jonathan
    Deriaz, Michel
    SENSORS, 2023, 23 (09)
  • [23] Beyond gait speed: exploring the added value of Inertial Measurement Unit-based measurements of gait in the estimation of the walking ability in daily life
    Felius, R. A. W.
    Wouda, N. C.
    Geerars, M.
    Bruijn, S. M.
    van Dieen, J. H.
    Punt, M.
    BMC NEUROLOGY, 2024, 24 (01)
  • [24] Determining the Most Appropriate Assistive Walking Device Using the Inertial Measurement Unit-Based Gait Analysis System in Disabled Patients
    Lee, Junhee
    Bae, Chang Hoon
    Jang, Aeri
    Yang, Seoyon
    Bae, Hasuk
    ANNALS OF REHABILITATION MEDICINE-ARM, 2020, 44 (01): : 48 - 57
  • [25] Angular velocity fusion of the microelectromechanical system inertial measurement unit array based on extended Kalman filter with correlated system noises
    Xing, Li
    Tu, Xiaowei
    Qian, Weixing
    Jin, Yang
    Qi, Pei
    MEASUREMENT & CONTROL, 2021, 54 (5-6): : 767 - 778
  • [26] Analysis of Power Systems Expansion Processes based on System Dynamics - State-of-the-Art
    Rios, Daniel
    Fernandez, Felix
    Blanco, Gerardo
    2016 IEEE BIENNIAL CONGRESS OF ARGENTINA (ARGENCON), 2016,
  • [27] The evolution of frailty assessment using inertial measurement sensor-based gait parameter measurements: A detailed analysis
    Amjad, Arslan
    Qaiser, Shahzad
    Blaszczyszyn, Monika
    Szczesna, Agnieszka
    WILEY INTERDISCIPLINARY REVIEWS-DATA MINING AND KNOWLEDGE DISCOVERY, 2024, 14 (06)
  • [28] Validation of wearable inertial sensor-based gait analysis system for measurement of spatiotemporal parameters and lower extremity joint kinematics in sagittal plane
    Patel, Gunjan
    Mullerpatan, Rajani
    Agarwal, Bela
    Shetty, Triveni
    Ojha, Rajdeep
    Shaikh-Mohammed, Javeed
    Sujatha, S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (05) : 686 - 696
  • [29] A NEW VALIDATION APPROACH FOR THE GROWTH RATE MEASUREMENT USING ELASTIC PHANTOMS GENERATED BY STATE-OF-THE-ART MICROFLUIDICS TECHNOLOGY
    El-Baz, A.
    Sethu, P.
    Gimel'farb, G.
    Khalifa, F.
    Elnakib, A.
    Falk, R.
    El-Ghar, M. Abo
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 4381 - 4384
  • [30] Inertial measurement unit sensor-based gait analysis in adults and older adults: A cross-sectional study
    Yoon, Dong Hyun
    Kim, Jeong-Hyun
    Lee, Kyuwon
    Cho, Jae-Sung
    Jang, Seong-Ho
    Lee, Shi-Uk
    GAIT & POSTURE, 2024, 107 : 212 - 217