Two-point method for kinetic analysis of a thermoluminescence glow peak

被引:3
|
作者
Ogundare, FO [1 ]
Chithambo, ML [1 ]
机构
[1] Rhodes Univ, Dept Phys, ZA-6140 Grahamstown, South Africa
来源
基金
新加坡国家研究基金会;
关键词
thermoluminescence; glow peak; kinetic analysis;
D O I
10.1080/10420150600704104
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a method for the estimation of defect (trap) physical parameters from thermoluminescence (TL) glow peaks. In this method, the order of kinetics b is determined using two values of TL intensity each of which corresponds to the same temperature (T-1) on two separate glow peaks of a phosphor. The two glow peaks are obtained from two aliquots of the phosphor irradiated to same dose but read out at different heating rates. The proposed method requires a minimum of only two data points in contrast to standard peak shape (PS) methods that require three points corresponding to three different temperatures on the same glow peak. Once the order of kinetics b is determined, the activation energy E is calculated by taking a second point (T-2) on any one of the two glow peaks. The values of b and E thus obtained are used to evaluate the frequency factor S'' and the number of trapped electrons before the heating begins n(o). The validity of the method was checked using two numerically generated glow peaks. For the two cases, the method reproduced the input values reasonably well. The method was also used to analyse two experimental glow peaks. The results obtained provide a reasonably good fit to the experimental data. The kinetic parameters calculated using the present technique are comparable to those calculated using PS and initial rise methods. Initial guesses can easily be obtained for E and S'' using the present technique when a glow curve is to be deconvoluted with a model consisting of many unknown parameters with E and S'' inclusive.
引用
收藏
页码:289 / 296
页数:8
相关论文
共 50 条
  • [21] A two-point in situ method for simultaneous analysis of radioactivity in seawater and sediment
    Lee, Jun-Ho
    Byun, Jong-In
    Lee, Dong-Myung
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (02) : 639 - 648
  • [22] A two-point in situ method for simultaneous analysis of radioactivity in seawater and sediment
    Jun-Ho Lee
    Jong-In Byun
    Dong-Myung Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 639 - 648
  • [23] The analysis of thermoluminescence glow curves
    Basun, S
    Imbusch, GF
    Jia, DD
    Yen, WM
    JOURNAL OF LUMINESCENCE, 2003, 104 (04) : 283 - 294
  • [24] On the analysis of thermoluminescence glow curve
    Prakash, J
    Prasad, D
    Rai, SK
    Singh, PK
    NATIONAL ACADEMY SCIENCE LETTERS-INDIA, 2001, 24 (5-12): : 107 - 111
  • [25] FAZO: A thermoluminescence glow curve analysis program by the deconvolution method
    Seghour, F.Z.
    Mebhah, D.
    Seghour, A.
    Radioprotection, 1998, 33 (01): : 47 - 62
  • [26] ANALYSIS OF THERMOLUMINESCENCE GLOW PATTERN
    RAO, DR
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1974, 22 (01): : 337 - 341
  • [27] NEW METHOD FOR NUMERICAL-ANALYSIS OF THERMOLUMINESCENCE GLOW CURVES
    SAKURAI, T
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (10) : 2139 - 2143
  • [28] KINETIC ANALYSIS OF THERMOLUMINESCENCE GLOW CURVES IN FELDSPAR: EVIDENCE FOR A CONTINUOUS DISTRIBUTION OF ENERGIES
    Pagonis, Vasilis
    Morthekai, P.
    Kitis, George
    GEOCHRONOMETRIA, 2014, 41 (02): : 168 - 177
  • [29] Computational Complexity for The Two-Point Block Method
    See, Phang Pei
    Majid, Zanariah Abdul
    INTERNATIONAL CONFERENCE ON QUANTITATIVE SCIENCES AND ITS APPLICATIONS (ICOQSIA 2014), 2014, 1635 : 187 - 194
  • [30] Clinical validation of the two-point method for predicting vancomycin AUC based on peak and trough plasma concentrations
    Wang, Liming
    Lin, Xiaolan
    Wang, Ling
    Ye, Hong
    Lin, Yuxing
    Ruan, Junshan
    Shi, Songqing
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2022, 44 (06) : 1325 - 1331