Sensitive, wide-range and high-throughput quantification of cyclosporine in whole blood using ultra-performance liquid chromatography coupled to tandem mass spectrometry and comparison with an antibody-conjugated magnetic immunoassay

被引:4
|
作者
Watanabe, Takuma [1 ]
Tanaka, Ryota [1 ]
Ono, Hiroyuki [1 ]
Suzuki, Yosuke [2 ]
Tatsuta, Ryosuke [1 ]
Itoh, Hiroki [1 ]
机构
[1] Oita Univ Hosp, Dept Clin Pharm, Hasama Machi, Yufu, Oita 8795593, Japan
[2] Meiji Pharmaceut Univ, Dept Medicat Use Anal & Clin Res, Tokyo, Japan
关键词
antibody‐ conjugated magnetic immunoassay; cyclosporine; therapeutic drug monitoring; ultra‐ performance liquid chromatography– tandem mass spectrometry;
D O I
10.1002/bmc.5128
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Because either trough or peak concentration at 2 h after administration is measured in routine therapeutic drug monitoring for cyclosporine A (CyA), a quantification method with a wide-range calibration curve capable of simultaneously measuring both concentrations is required. We developed a sensitive, wide-range and high-throughput quantification method for CyA in whole blood using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), and compared patients' blood CyA levels measured by UPLC-MS/MS and antibody-conjugated magnetic immunoassay (ACMIA). Whole blood samples were prepared by solid-phase extraction using Oasis HLB mu Elution plate. The UPLC-MS/MS assay showed excellent linearity over a wide calibration range of 5-2500 ng/mL. Within-batch accuracy and precision as well as batch-to-batch accuracy and precision fulfilled the criteria of US Food and Drug Administration guidelines. The blood CyA concentrations measured by the UPLC-MS/MS assay correlated strongly with those measured by ACMIA. A Bland-Altman plot showed a fixed error between CyA concentrations measured by the two methods, and the concentrations measured by the UPLC-MS/MS method were consistently lower than those measured by ACMIA. We have succeeded to develop a sensitive, wide-range and high-throughput quantification method for CyA in whole blood using UPLC-MS/MS.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] High-sensitivity simultaneous quantification of tacrolimus and 13-O-demethyl tacrolimus in human whole blood using ultra-performance liquid chromatography coupled to tandem mass spectrometry
    Ono, Hiroyuki
    Suzuki, Yosuke
    Kaneko, Tetsuya
    Tanaka, Ryota
    Sato, Fuminori
    Sato, Yuhki
    Mimata, Hiromitsu
    Itoh, Hiroki
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (09)
  • [22] High-throughput analysis of ramelteon, agomelatine, and melatonin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry
    Ogawa, Tadashi
    Iwai, Masae
    Hattori, Hideki
    Zaitsu, Kei
    Kumazawa, Takeshi
    Ishii, Akira
    Suzuki, Osamu
    Seno, Hiroshi
    FORENSIC TOXICOLOGY, 2014, 32 (01) : 126 - 131
  • [23] Extraction and Quantification of Sphingolipids from Hemiptera Insects by Ultra-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Wang, Ni
    Shi, Xiaoxiao
    Zhang, Chao
    Zhou, Wenwu
    Zhu, Zengrong
    BIO-PROTOCOL, 2021, 11 (04):
  • [24] High-throughput determination of pesticide residues in food commodities by use of ultra-performance liquid chromatography-tandem mass spectrometry
    Garrido Frenich, A.
    Martinez Vidal, J. L.
    Pastor-Montoro, E.
    Romero-Gonzalez, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 947 - 959
  • [25] Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and ultra-performance liquid chromatography tandem mass spectrometry
    Pichini, Simona
    Gottardi, Massimo
    Marchei, Emilia
    Svaizer, Fiorenza
    Pellegrini, Manuela
    Rotolo, Maria Concetta
    Garcia Algar, Oscar
    Pacifici, Roberta
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (05) : 679 - 686
  • [26] Bile Acid Profiling and Quantification in Biofluids Using Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry
    Sarafian, Magali H.
    Lewis, Matthew R.
    Pechlivanis, Alexandros
    Ralphs, Simon
    McPhail, Mark J. W.
    Patel, Vishal C.
    Dumas, Marc-Emmanuel
    Holmes, Elaine
    Nicholson, Jeremy K.
    ANALYTICAL CHEMISTRY, 2015, 87 (19) : 9662 - 9670
  • [27] Development and validation of sensitive and selective quantification of total and free daptomycin in human plasma using ultra-performance liquid chromatography coupled to tandem mass spectrometry
    Tanaka, Ryota
    Suzuki, Yosuke
    Goto, Koji
    Yasuda, Norihisa
    Koga, Hironori
    Kai, Shinya
    Ohchi, Yoshifumi
    Sato, Yuhki
    Kitano, Takaaki
    Itoh, Hiroki
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 : 56 - 64
  • [28] High-throughput analysis of 19 endogenous androgenic steroids by ultra-performance convergence chromatography tandem mass spectrometry
    Quanson, Jonathan L.
    Stander, Marietjie A.
    Pretorius, Elzette
    Jenkinson, Carl
    Taylor, Angela E.
    Storbeck, Karl-Heinz
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1031 : 131 - 138
  • [29] Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry - a method comparison and validation
    Bruce, Stephen J.
    Rochat, Bertrand
    Beguin, Alexandre
    Pesse, Benoit
    Guessous, Idris
    Boulat, Olivier
    Henry, Hugues
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 200 - 206
  • [30] Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Nielsen, Marie Katrine Klose
    Johansen, Sys Stybe
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (07) : 497 - 506