Sensitive, wide-range and high-throughput quantification of cyclosporine in whole blood using ultra-performance liquid chromatography coupled to tandem mass spectrometry and comparison with an antibody-conjugated magnetic immunoassay

被引:4
|
作者
Watanabe, Takuma [1 ]
Tanaka, Ryota [1 ]
Ono, Hiroyuki [1 ]
Suzuki, Yosuke [2 ]
Tatsuta, Ryosuke [1 ]
Itoh, Hiroki [1 ]
机构
[1] Oita Univ Hosp, Dept Clin Pharm, Hasama Machi, Yufu, Oita 8795593, Japan
[2] Meiji Pharmaceut Univ, Dept Medicat Use Anal & Clin Res, Tokyo, Japan
关键词
antibody‐ conjugated magnetic immunoassay; cyclosporine; therapeutic drug monitoring; ultra‐ performance liquid chromatography– tandem mass spectrometry;
D O I
10.1002/bmc.5128
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Because either trough or peak concentration at 2 h after administration is measured in routine therapeutic drug monitoring for cyclosporine A (CyA), a quantification method with a wide-range calibration curve capable of simultaneously measuring both concentrations is required. We developed a sensitive, wide-range and high-throughput quantification method for CyA in whole blood using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), and compared patients' blood CyA levels measured by UPLC-MS/MS and antibody-conjugated magnetic immunoassay (ACMIA). Whole blood samples were prepared by solid-phase extraction using Oasis HLB mu Elution plate. The UPLC-MS/MS assay showed excellent linearity over a wide calibration range of 5-2500 ng/mL. Within-batch accuracy and precision as well as batch-to-batch accuracy and precision fulfilled the criteria of US Food and Drug Administration guidelines. The blood CyA concentrations measured by the UPLC-MS/MS assay correlated strongly with those measured by ACMIA. A Bland-Altman plot showed a fixed error between CyA concentrations measured by the two methods, and the concentrations measured by the UPLC-MS/MS method were consistently lower than those measured by ACMIA. We have succeeded to develop a sensitive, wide-range and high-throughput quantification method for CyA in whole blood using UPLC-MS/MS.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry for Cyclosporine Analysis in Human Whole Blood and Comparison With an Antibody-Conjugated Magnetic Immunoassay
    Mei, Shenghui
    Wang, Jiaqing
    Chen, Di
    Zhu, Leting
    Zhao, Ming
    Hu, Xin
    Yang, Li
    Zhao, Zhigang
    THERAPEUTIC DRUG MONITORING, 2018, 40 (01) : 69 - 75
  • [2] COMPARISON OF ANTIBODY-CONJUGATED MAGNETIC IMMUNOASSAY AND LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY FOR THE MEASUREMENT OF CYCLOSPORINE AND TACROLIMUS IN WHOLE BLOOD
    Cangemi, G.
    Barco, S.
    Bonifazio, P.
    Maffia, A.
    Agazzi, A.
    Melioli, G.
    INTERNATIONAL JOURNAL OF IMMUNOPATHOLOGY AND PHARMACOLOGY, 2013, 26 (02) : 419 - 426
  • [3] High-throughput and wide-range simultaneous determination of linezolid, daptomycin and tedizolid in human plasma using ultra-performance liquid chromatography coupled to tandem mass spectrometry
    Tanaka, Ryota
    Kai, Makoto
    Goto, Koji
    Ohchi, Yoshifumi
    Yasuda, Norihisa
    Tatsuta, Ryosuke
    Kitano, Takaaki
    Itoh, Hiroki
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 194
  • [4] High-throughput and sensitive screening by ultra-performance liquid chromatography tandem mass spectrometry of diuretics and other doping agents
    Ventura, Rosa
    Roig, Meritxell
    Monfort, Nuria
    Saez, Pillar
    Berges, Rosa
    Segura, Jordi
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2008, 14 (03) : 191 - 200
  • [5] Pitfall in the high-throughput quantification of whole blood cyclosporin A using liquid chromatography-tandem mass spectrometry
    Vogeser, M
    Spöhrer, U
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (04) : 400 - 402
  • [6] Ultra-performance liquid chromatography/tandem mass spectrometry in high-throughput detection, quantification and confirmation of anabolic steroids in equine plasma
    You, Youwen
    Uboh, Cornelius E.
    Soma, Lawrence R.
    Guan, Fuyu
    Li, Xiaoqing
    Rudy, Jeffrey A.
    Liu, Ying
    Chen, Jinwen
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (13) : 2035 - 2044
  • [7] High-Sensitivity and High-Throughput Quantification of Everolimus in Human Whole Blood Using Ultrahigh-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry
    Miyagi, Chika
    Tanaka, Ryota
    Hirata, Kenshiro
    Watanabe, Takuma
    Tatsuta, Ryosuke
    Miyamura, Shigeyuki
    Itoh, Hiroki
    THERAPEUTIC DRUG MONITORING, 2022, 44 (05) : 633 - 640
  • [8] High-throughput quantification for a drug mixture in rat plasma -: a comparison of Ultra PerformanceTM liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry
    Yu, K
    Little, D
    Plumb, R
    Smith, B
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (04) : 544 - 552
  • [9] Comparison between ultra-performance liquid chromatography with tandem mass spectrometry and a chemiluminescence immunoassay in the determination of cyclosporin A and tacrolimus levels in whole blood
    Lee, Yong-Wha
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (06) : 1535 - 1539
  • [10] Quantitative Determination of Cyclosporine in Human Whole Blood by Ultra-Performance Liquid Chromatography with Triple Quadrupole Tandem Mass Spectrometry
    Jung, Hyun Jin
    Gwon, Mi-Ri
    Park, Jeonghyeon
    Seo, Jeong Ju
    Seong, Sook Jin
    Kim, Eun Hee
    Suh, Soon Rim
    Jeong, Ji Yun
    Lee, Hae Won
    Yoon, Young-Ran
    ANALYTICAL SCIENCES, 2014, 30 (02) : 293 - 298