Improving the stability of cryogenic current comparator setups

被引:25
|
作者
Drung, D. [1 ]
Goetz, M. [2 ]
Pesel, E. [2 ]
Storm, J. -H [1 ]
Assmann, C. [1 ]
Peters, M. [1 ]
Schurig, Th [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[2] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2009年 / 22卷 / 11期
关键词
SQUIDs;
D O I
10.1088/0953-2048/22/11/114004
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have realized an improved resistance calibration setup based on a cryogenic current comparator (CCC). The comparator, with 18 windings and 4647 turns in total, is well-suited for all the necessary comparisons with a 100 Omega standard resistor with the quantum Hall effect and inside the range of standard resistance values from 1 Omega to 1 M Omega. The new state-of-the-art setup is equipped with a low-noise dc SQUID (superconducting quantum interference device) and a digital double current source. Proper damping of the CCC resonance, careful electronics design ('box-in-box') and application of internal wideband feedback to the SQUID sensor improve the dynamic stability considerably and lower the overall measurement time as compared against our previous setup.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] 1:30000 Cryogenic Current Comparator with optimum SQUID readout
    Bartolomé, E
    Sesé, J
    Rietveld, G
    Flokstra, J
    Rillo, C
    Camón, A
    Rogalla, H
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 280 - 281
  • [42] Results from a detailed calculation of the sensitivity of a cryogenic current comparator
    Early, MD
    van Dam, MA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 379 - 382
  • [43] THE RATIO ERROR OF THE OVERLAPPED-TUBE CRYOGENIC CURRENT COMPARATOR
    SEPPA, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (05) : 689 - 697
  • [44] Resistance bridge based on the Cryogenic Current Comparator in a transport dewar
    Bartolomé, E
    Camón, A
    Sesé, J
    Rillo, C
    Flokstra, J
    Rietveld, G
    Rogalla, H
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 867 - 870
  • [45] Precise Measurement of the Quantized Hall Resistance on the Basis of a Cryogenic Current Comparator
    Kim, Wan-Seop
    Yu, Kwang Min
    Kim, Mun-Seog
    Park, Po Gyu
    Kim, Kyu-Tae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (05) : 1339 - 1342
  • [47] Stability of the multichannel comparator for heavy direct current
    Hebei Electric Power Research Institute, Shijiazhuang 050021, China
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (08): : 1563 - 1566
  • [48] A cryogenic current comparator bridge for resistance measurements at currents of up to 100 A
    Williams, JM
    Kleinschmidt, P
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 163 - 164
  • [49] Influence of Mechanical Deformations on the Performance of a Coaxial Shield for a Cryogenic Current Comparator
    Marsic, Nicolas
    Mueller, Wolfgang F. O.
    Tympel, Volker
    Stoehlker, Thomas
    Stapelfeld, Max
    Schmidl, Frank
    Schmelz, Matthias
    Zakosarenko, Vyacheslav
    Stolz, Ronny
    Haider, David
    Sieber, Thomas
    Schwickert, Marcus
    De Gersem, Herbert
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (09)
  • [50] DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER FOR CRYOGENIC CURRENT COMPARATOR
    NAKANISHI, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (10): : 5713 - 5717