Cardiac CT: Technical considerations

被引:2
|
作者
Dehaene, J-L [1 ]
Rousseau, H. [2 ]
Chabbert, V. [2 ]
机构
[1] Polyclin Bois, Serv Radiol, F-59000 Lille, France
[2] Hop Rangueil, Serv Radiol, TSA 50032, F-31059 Toulouse 9, France
来源
JOURNAL DE RADIOLOGIE | 2009年 / 90卷 / 09期
关键词
Multi-detector row computed tomography; Technical recommendations; Coronary artery disease; Myocardial infarction; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CARDIOLOGY; RADIOLOGY;
D O I
10.1016/S0221-0363(09)73258-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The possibility to perform cardiac and coronary imaging was a major driving force behind an ongoing, rapid evolution of scanner technology, accompanied by improvements of software and post-processing tools. The most recent generations of MDCT with the ability to acquire at least 64 slices simultaneously allow relatively robust morphological and functional imaging of the heart. By nature of its target, the continuously moving heart, cardiac CT is technically more challenging than other CT applications. Also, rapid technical development requires constant adaptation of acquisition protocols. The present manuscript summarizes the current state of technology of cardiac CT. Included are considerations regarding appropriate patient selection, patient medication, contrast enhancement, acquisition and reconstruction parameters, image display and analysis techniques with a special emphasis on radiation dose and all possible measures to keep the dose. It does not constitute a meta-analysis of published literature, but merely reflects an expert consensus on the current technical aspects of cardiac CT imaging.
引用
收藏
页码:1119 / 1122
页数:4
相关论文
共 50 条
  • [41] Dual-energy CT in musculoskeletal imaging: technical considerations and clinical applications
    Albano, Domenico
    Di Luca, Filippo
    D'Angelo, Tommaso
    Booz, Christian
    Midiri, Federico
    Gitto, Salvatore
    Fusco, Stefano
    Serpi, Francesca
    Messina, Carmelo
    Sconfienza, Luca Maria
    RADIOLOGIA MEDICA, 2024, 129 (07): : 1038 - 1047
  • [42] Technical considerations for implementation of X-ray CT polymer gel dosimetry
    Hilts, M
    Jirasek, A
    Duzenli, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08): : 1727 - 1745
  • [43] Quantitative functional imaging with CT perfusion: technical considerations, kinetic modeling, and applications
    Chung, Kevin J.
    De Sarno, Danny
    Lee, Ting-Yim
    FRONTIERS IN PHYSICS, 2023, 11
  • [44] Peripheral vs. Central Cannulation in Cardiac Reoperations: Technical Considerations and Outcomes
    Ata, Emin Can
    Erkanli, Korhan
    Ulukan, Mustafa Ozer
    Yildiz, Yahya
    Turkoglu, Halil
    Pasli, Sedat
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2020, 35 (04) : 420 - 426
  • [45] Technical considerations in implanting left ventricular pacing leads for cardiac resynchronisation therapy
    Stellbrink, C
    Breithardt, OA
    Hanrath, P
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2004, 6 (0D) : D43 - D46
  • [46] Technical innovation of cardiac multirow detector CT using multisector reconstruction
    Horiguchi, J
    Nakanishi, T
    Tamura, A
    Ito, K
    Sasaki, K
    Shen, Y
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (04) : 217 - 226
  • [47] Influence of technical parameters on epicardial fat volume quantification at cardiac CT
    Bucher, Andreas M.
    Schoepf, U. Joseph
    Krazinski, Aleksander W.
    Silverman, Justin
    Spearman, James V.
    De Cecco, Carlo N.
    Meinel, Felix G.
    Vogl, Thomas J.
    Geyer, Lucas L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) : 1062 - 1067
  • [48] Techniques and technical considerations
    Vicini, F.
    CANCER RESEARCH, 2019, 79 (04)
  • [49] TECHNICAL CONSIDERATIONS IN ORTHOPAEDICS
    HACKENBROCH, M
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1956, 81 (37) : 1493 - 1497
  • [50] TECHNICAL CONSIDERATIONS IN IMMUNOCYTOCHEMISTRY
    HUTSON, JC
    GARDNER, PJ
    BAUER, TW
    MORIARTY, GC
    ANATOMICAL RECORD, 1976, 184 (03): : 433 - 434