Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners

被引:8
|
作者
Wang, Zhiyue J. [1 ,2 ]
Rollins, Nancy K. [1 ,2 ]
Liang, Hui [3 ]
Park, Yong Jong [4 ]
机构
[1] Childrens Med Ctr, Dept Radiol, Dallas, TX 75235 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
[3] Texas A&M Univ, Baylor Coll Dent, Dallas, TX 75246 USA
[4] Childrens Med Ctr, Div Orthodont, Dallas, TX 75235 USA
关键词
MRI artifacts; orthodontic appliances; stainless steel; induced magnetic moment; FIELD INTERACTIONS; IMAGING ARTIFACTS; DENTAL MATERIALS; STROKE; IMAGES;
D O I
10.1118/1.4930796
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Most orthodontic appliances are made of stainless steel materials and induce severe magnetic susceptibility artifacts in brain MRI. In an effort for correcting these artifacts, it is important to know the value of induced magnetic moments in all parts of orthodontic appliances. In this study, the induced magnetic moment of stainless steel orthodontic brackets, molar bands, and arch-wires from several vendors is measured. Methods: Individual stainless steel brackets, molar bands, and short segments of arch-wire were positioned in the center of spherical flask filled with water through a thin plastic rod. The induced magnetic moment at 1.5 T was determined by fitting the B-0 map to the z-component of the magnetic dipole field using a computer routine. Results: The induced magnetic moment at 1.5 T was dominated by the longitudinal component m(z), with a small contribution from the transverse components. The m(z) was insensitive to the orientation of the metal parts. The orthodontic brackets collectively dominated the magnetic dipole moment in orthodontic appliances. In brackets from six vendors, the total induced m(z) from 20 brackets for nonmolar teeth ranged from 0.108 to 0.158 (median 0.122) A.m(2). The m(z) in eight molar bands with bracket attachment from two vendors ranged from 0.0004 to 0.0166 (median 0.0035) A.m(2). Several full length arch wires had induced magnetic moment in the range of 0.006-0.025 (median 0.015) A.m(2). Conclusions: Orthodontic brackets collectively contributed most to the total magnetic moment. Different types of brackets, molar bands, and arch wires all exhibit substantial variability in the induced magnetic moment. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:5871 / 5878
页数:8
相关论文
共 50 条
  • [1] Correcting B0 Field Distortions in MRI Caused by Stainless Steel Orthodontic Appliances at 1.5 T Using Permanent Magnets – A Head Phantom Study
    Zhiyue J. Wang
    Yong Jong Park
    Michael C. Morriss
    Youngseob Seo
    Trung Nguyen
    Rami R. Hallac
    Ana Nava
    Rajiv Chopra
    Yonatan Chatzinoff
    Khyana Price
    Nancy K. Rollins
    Scientific Reports, 8
  • [2] Correcting B0 Field Distortions in MRI Caused by Stainless Steel Orthodontic Appliances at 1.5 T Using Permanent Magnets - A Head Phantom Study
    Wang, Zhiyue J.
    Park, Yong Jong
    Morriss, Michael C.
    Seo, Youngseob
    Trung Nguyen
    Hallac, Rami R.
    Nava, Ana
    Chopra, Rajiv
    Chatzinoff, Yonatan
    Price, Khyana
    Rollins, Nancy K.
    SCIENTIFIC REPORTS, 2018, 8
  • [3] Magnetic fields from electric toothbrushes promote corrosion in orthodontic stainless steel appliances but not in titanium appliances
    Kameda, Takashi
    Ohkuma, Kazuo
    Oda, Hirotake
    Sano, Natsuki
    Batbayar, Nomintsetseg
    Terashima, Yukari
    Sato, Soh
    Terada, Kazuto
    DENTAL MATERIALS JOURNAL, 2013, 32 (06) : 959 - 969
  • [4] Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging
    Blankenstein, Felix H.
    Asbach, Patrick
    Beuer, Florian
    Glienke, Johannes
    Mayer, Stefan
    Zachriat, Christine
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (01) : 281 - 289
  • [5] Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging
    Felix H. Blankenstein
    Patrick Asbach
    Florian Beuer
    Johannes Glienke
    Stefan Mayer
    Christine Zachriat
    Clinical Oral Investigations, 2017, 21 : 281 - 289
  • [6] Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners
    Sonesson, Mikael
    Al-Qabandi, Fahad
    Mansson, Sven
    Abdulraheem, Salem
    Bondemark, Lars
    Hellen-Halme, Kristina
    IMAGING SCIENCE IN DENTISTRY, 2021, 51 (01) : 63 - 71
  • [7] Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems
    Kemper, J.
    Priest, A. N.
    Schulze, D.
    Kahl-Nieke, B.
    Adam, G.
    Klocke, A.
    EUROPEAN RADIOLOGY, 2007, 17 (02) : 533 - 540
  • [8] Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems
    J. Kemper
    A. N. Priest
    D. Schulze
    B. Kahl-Nieke
    G. Adam
    A. Klocke
    European Radiology, 2007, 17 : 533 - 540
  • [9] Failure investigation of soldered stainless steel orthodontic appliances exposed to artificial saliva
    Vahed, Anisa
    Lachman, Nirusha
    Knutsen, Robert D.
    DENTAL MATERIALS, 2007, 23 (07) : 855 - 861
  • [10] CORROSION DAMAGE INVESTIGATION OF SILVER-SOLDERED STAINLESS STEEL ORTHODONTIC APPLIANCES USED IN VIVO
    Lepicka, M.
    Gradzka-Dahlke, M.
    Szarmach, I.
    ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (04) : 2569 - 2572