Hydrodynamic behavior of inverse fluidized bed biofilm reactor for phenol biodegradation using Pseudomonas fluorescens

被引:16
|
作者
Begum, Sabarunisha S. [1 ]
Radha, K. V. [1 ]
机构
[1] Anna Univ, AC Coll Technol, Dept Chem Engn, Madras 600025, Tamil Nadu, India
关键词
Fluidized Bed; Hydrodynamics; Hold Up; Phenol; Degradation; WASTE-WATER TREATMENT; MASS-TRANSFER; STEADY-STATE; INHIBITION-KINETICS; DRAFT-TUBE; DEGRADATION; BIOREACTOR; PREDICTION; VELOCITY; 2-PHASE;
D O I
10.1007/s11814-013-0260-z
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The hydrodynamic characteristic performance of an internal draft tube inverse fluidized bed biofilm reactor was studied for the aerobic biodegradation of phenol (1,200 mg/l) using Pseudomonas fluorescens for various ratios of settled bed volume to reactor working volume (V (b) /V (r) ) under batchwise condition with respect to liquid phase. The operating parameters, such as superficial gas velocity, phase hold ups, aspect ratio and bed height, were analyzed for different ratios of (V (b) /V (r) ). The effect of biodegradation on synthetic phenolic effluent was determined from the reduction in chemical oxygen demand and phenol removal efficiency. The optimum value of (V (b) /V (r) ) (m) was 0.20 for the optimal superficial gas velocity, U (gm) =0.220 m/s with the COD reduction efficiency of 98.5% in 48 hours. The biomass and biofilm characteristics of P. fluorescens were determined for optimal hydrodynamic operating parameters by evaluating its biofilm dry density and thickness, bioparticle density, suspended and attached biomass concentration.
引用
收藏
页码:436 / 445
页数:10
相关论文
共 50 条
  • [31] Mass transfer correlation for phenol biodegradation in a fluidized bed bioreactor
    Vinod, A. Venu
    Reddy, G. Venkat
    JOURNAL OF HAZARDOUS MATERIALS, 2006, 136 (03) : 727 - 734
  • [32] Biodegradation kinetics of ferrous(II) cyanide complex ions by immobilized Pseudomonas fluorescens in a packed bed column reactor
    Dursun, AY
    Aksu, Z
    PROCESS BIOCHEMISTRY, 2000, 35 (06) : 615 - 622
  • [33] Comparative studies on modelling and optimization of hydrodynamic parameters on inverse fluidized bed reactor using ANN-GA and RSM
    Prabhu, M. Venkatesh
    Karthikeyan, R.
    ALEXANDRIA ENGINEERING JOURNAL, 2018, 57 (04) : 3019 - 3032
  • [34] Mathematical prediction of COD removal using interrelation of operating variables of the aerobic inverse fluidized bed biofilm reactor (AIFBBR)
    Challa, Mallikarjuna
    Dash, Rajesh Roshan
    PROCESS BIOCHEMISTRY, 2025, 150 : 257 - 264
  • [35] Chalk as the carrier for nitrifying biofilm in a fluidized bed reactor
    Green, M
    Ruskol, Y
    Lahav, O
    Tarre, S
    WATER RESEARCH, 2001, 35 (01) : 284 - 290
  • [36] COLLOID REMOVAL IN FLUIDIZED-BED BIOFILM REACTOR
    SPROUSE, G
    RITTMANN, BE
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1990, 116 (02): : 314 - 329
  • [37] Hydrodynamic aspects in anaerobic fluidized bed reactor modeling
    Fuentes, Mauren
    Scenna, Nicolas J.
    Aguirre, Pio A.
    Mussati, Miguel C.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (9-10) : 1530 - 1540
  • [38] Fluidization and reactor biomass characteristics of the denitrification fluidized bed biofilm reactor
    Mulcahy, L.T.
    Shieh, W.K.
    1600, (21):
  • [39] Phenol biodegradation and simultaneous nitrogen removal using a carbon fiber felt biofilm reactor
    Chen, Yingwen
    Liu, Mingqing
    Xu, Fuyuan
    Zhu, Shemin
    Shen, Shubao
    WATER SCIENCE AND TECHNOLOGY, 2010, 62 (05) : 1052 - 1059