An MCFC stack consisting of 20 unit cells with an effective electrode area of 3,000 cm(2) was prepared and operated to verify the performance and reliability of the cells. All the porous cell components such as anode, cathode and matrix including electrolyte sheets were manufactured by the tape casting method. Hard-rail type separator made with AISI 316 L stainless steel was used for separating fuel and oxidant gases and conducting electricity between unit cells as well. When fuel gas (H-2 : CO2 : H2O = 72 : 18 : 10) and oxidant gas (Air: CO, = 70 : 30) were supplied at a flow rate of 40% utilization to the stack at 650 degrees C, the output power of the stack was measured as 7.6 kW at its peak time. This was much higher than the design value of 6 kW In addition to this high performance, the standard deviation of cell voltage among 20 unit cells was a mere 3 mV. The stack showed little performance decay up to 1,800 hours of operation time. After an unexpected thermal cycle due to the failure of the pre-heater for fuel gas around 2,000 hours, however, the decay rate became larger accordingly with operating time. The total operation time reached 5,600 hours including 4,800 hours under load in which a total of 23,202 kWh was generated. The evaluation of the stack was quite satisfactory in general except for the difficulty in temperature control under full load.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 50 条
  • [31] Numerical studies of a separator for stack temperature control in a molten carbonate fuel cell
    Kim, Do Hyung
    Kim, Beom Joo
    Lim, Hee Chun
    Lee, Choong Gon
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (14) : 8499 - 8507
  • [32] Hybrid dynamic modeling and control of molten carbonate fuel cell stack shutdown
    Li, Yong
    Cao, Guang-Yi
    Zhu, Xin-Jian
    Journal of Donghua University (English Edition), 2007, 24 (01) : 35 - 38
  • [33] MOLTEN-CARBONATE FUEL-CELL STACK PERFORMANCE WITH GAS RECYCLING
    WATANABE, T
    IZAKI, Y
    MUGIKURA, Y
    ABE, T
    SAITO, H
    MATSUYAMA, T
    SHIMIZU, T
    SATO, S
    OGOSHI, M
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (06) : 35 - 47
  • [34] Fabrication and characteristics of anode as an electrolyte reservoir for molten carbonate fuel cell
    Youn, Ju Young
    Yoon, Sung Pil
    Han, Jonghee
    Nam, Suk Woo
    Lim, Tae-Hoon
    Hong, Seong-Ahn
    Lee, Kwan Young
    JOURNAL OF POWER SOURCES, 2006, 157 (01) : 121 - 127
  • [35] Detailed Dynamic Modeling of a Molten Carbonate Fuel Cell Stack with Indirect Internal Reformers
    Kim, H.
    Cho, J. H.
    Lee, K. S.
    FUEL CELLS, 2013, 13 (02) : 259 - 269
  • [36] Numerical Analysis of Molten Carbonate Fuel Cell Stack Using Computational Fluid Dynamics
    Lee, Kab Soo
    Cho, Hyun Ho
    JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2005, 8 (04): : 155 - 161
  • [37] Design improvement of circular molten carbonate fuel cell stack through CFD Analysis
    Verda, Vittorio
    Sciacovelli, Adriano
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2740 - 2748
  • [38] Performance and life of 10-kW molten-carbonate fuel cell stack using Li/K and Li/Na carbonates as the electrolyte
    Mugikura, Y
    Yoshiba, F
    Izaki, Y
    Watanabe, T
    Takahashi, K
    Takashima, S
    Kahara, T
    JOURNAL OF POWER SOURCES, 1998, 75 (01) : 108 - 115
  • [39] NOVEL FABRICATION TECHNIQUE FOR MOLTEN CARBONATE FUEL-CELL ELECTROLYTE STRUCTURES
    GRIMALDI, JJ
    DECARLO, VJ
    GLUGLA, PG
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1980, 127 (08) : C355 - C355
  • [40] ALTERNATE FABRICATION PROCESS FOR MOLTEN CARBONATE FUEL-CELL ELECTROLYTE STRUCTURES
    ARENDT, RH
    CURRAN, MJ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1980, 127 (08) : 1663 - 1666