Outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent in patients with chronic total occlusions: A multicenter registry

被引:6
|
作者
Azzalini, Lorenzo [1 ]
Demir, Ozan M. [1 ]
Gasparini, Agabriele L. [2 ]
Grancini, Luca [3 ]
La Manna, Alessio [4 ]
Ojeda, Soledad [5 ]
Benincasa, Susanna [1 ]
Bellini, Barbara [1 ]
Poletti, Enrico [1 ]
Maccagni, Davide [1 ]
Soldi, Margherita [2 ]
Lannetta, Loredana [3 ]
Trabattoni, Daniela [3 ,6 ]
Gravina, Giacomo [4 ]
Hidalgo, Francisco [5 ]
Giannini, Francesco [1 ]
Pan, Manuel
Tamburino, Corrado [4 ]
Bartorelli, Antonio L. [3 ,6 ]
Reimers, Bernhard [2 ]
Godino, Cosmo [1 ]
Carlino, Mauro [1 ]
Colombo, Antonio [1 ]
机构
[1] Ist Sci San Raffaele, Cardiothorac Vasc Dept, Intervent Cardiol Div, Via Olgettina 60, I-20132 Milan, Italy
[2] Humanitas Res Hosp, Invas Cardiol & Hemodynam, Rozzano, Italy
[3] IRCCS Ctr Cardiol Monzino, Dept Cardiovasc Sci, Milan, Italy
[4] Univ Catania, Ferrarotto Hosp, Div Cardiol, Catania, Italy
[5] Univ Cordoba, Reim Sofia Hosp, Intervent Cardiol, Cordoba, Spain
[6] Univ Milan, Milan, Italy
关键词
Chronic total occlusion; Drug-eluting stents; Bioresorbable polymer; Percutaneous coronary intervention; PERCUTANEOUS CORONARY INTERVENTION; CLINICAL-EVALUATION; DURABLE POLYMER; TRIAL; SYSTEM; LESIONS; ARTERY;
D O I
10.1016/j.ijcard.2018.01.115
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We aimed to evaluate the mid-term outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent (BP-SES) in chronic total occlusion (CTO) percutaneous coronary intervention (PCI), as compared with durable-polymer everolimus-eluting stents (EES). Methods: We compiled a multicenter registry of patients undergoing CTO recanalization followed by BP-SES or EES implantation. The primary endpoint was the incidence of target-lesion failure (TLF, a composite of cardiac death, target-vessel myocardial infarction, and target-lesion revascularization) at one year. Propensity score matching (PSM) was used to adjust for case mix. Results: Overall, 413 patients were included (BP-SES n = 242, EES n = 171). PSM resulted in 131 matched pairs, which represented the subject of the main analysis. Antegrade wire escalation was the most successful crossing technique (66% vs. 63%, p = 0.98) in both the BP-SES and EES groups, respectively. Procedural success rates were similar between groups (BP-SES 96% vs. EES 93%, p = 0.24). At one-year follow-up, there were no differences in the primary endpoint of TLF (5.7% vs. 8.3%, p = 0.44), and in cardiac death (0.9% vs. 2.8%, p = 0.32), target-vessel myocardial infarction (0.9% vs 1.9%, p = 0.57), target-lesion revascularization (3.7% vs 3.7%, p = 0.99), or stent thrombosis (0.9% vs. 1.9%, P = 0.57), in BP-SES vs. EES, respectively. Conclusions: Patients undergoing CTO PCI with BP-SES suffer a low rate of TLF at one-year follow-up, which is similar to that of subjects treated with durable-polymer EES. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
  • [11] FOUR-YEAR DURABILITY OF SIROLIMUS-ELUTING STENT IN PATIENTS WITH CHRONIC TOTAL OCCLUSIONS COMPARED WITH BARE METAL STENT: MULTICENTER REGISTRY IN ASIA
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo Hans
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [12] Four-year durability of Sirolimus-Eluting Stent in patients with chronic total occlusions compared with bare metal stent: Multicenter registry in Asia
    Nakamura, S.
    Bae, J. H.
    Cahyadi, Y. H.
    Udayachalerm, W.
    Tresukosol, D.
    Tansuphaswadikul, S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 461 - 461
  • [13] Four-year durability of Sirolimus-eluting stent in patients with chronic total occlusions compared with rare metal stent: Multicenter registry in Asia
    Nakamura, Sunao
    Nakamura, Shotaro
    Bae, Jang-Ho
    Cahyadi, Yee H.
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 93L - 93L
  • [14] Four-Year Durability of Sirolimus-Eluting Stent in Patients with Chronic Total Occlusions Compared with Bare Metal Stent: Multicenter Registry in Asia
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo Hans
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 90D - 91D
  • [15] Impact of sirolimus-eluting stent on the outcome of patients with sirolimus-eluting stent failure: multicenter registry in Asia
    Nakamura, S.
    Bae, J. H.
    Cahyadi, Y. H.
    Udayachalerm, W.
    Tresukosol, D.
    Tansuphaswadikul, S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 654 - 654
  • [16] Impact of Sirolimus-eluting stent on the outcome of patients with Sirolimus-eluting stent failure: Multicenter registry in Asia
    Nakamura, S
    Bae, JH
    Cahyadi, YH
    Udayachalerm, W
    Tresukosol, D
    Tansuphaswadikul, S
    CIRCULATION, 2005, 112 (17) : U800 - U801
  • [17] Serial assessment of bioresorbable-polymer sirolimus-eluting stent by coronary angioscopy and optical coherence tomography
    Nakamura, Shun
    Kimura, Shigeki
    Nakagama, Shun
    Hayashi, Yosuke
    Yamamoto, Tasuku
    Utsugi, Yuya
    Doi, Junichi
    Mizusawa, Masafumi
    Araki, Makoto
    Sudo, Yuta
    Hishikari, Keiichi
    Hikita, Hiroyuki
    Takahashi, Atsushi
    Isobe, Mitsuaki
    CORONARY ARTERY DISEASE, 2017, 28 (06) : 530 - 531
  • [18] Impact of Sirolimus-eluting stent and paclitaxel-eluting stent on the outcome of patients with Sirolimus-eluting stent failure: Multicenter registry
    Nakamura, Sunao
    Bae, Jang-Ho
    Cahyadi, Yeo H.
    Udqyachalerm, Wasan
    Tresukosol, Damras
    Tansuphasivadikul, Sudaratana
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 37L - 37L
  • [19] Comparison of efficacy and safety between Sirolimus-eluting stent (Cypher) and paclitaxel-eluting stent (TAXUS) on the outcome of patients with chronic total occlusions: multicenter registry in Asia
    Nakamura, S.
    Bae, J. H.
    Cahyadi, Y. H.
    Udayachalerm, W.
    Tresukosol, D.
    Tansuphaswadikul, S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 924 - 924
  • [20] Comparison of efficacy and safety between Sirolimus-eluting stent (Cypher™) and paclitaxel-eluting stent (TAXUS™) on the outcome of patients with chronic total occlusions:: Multicenter registry in Asia
    Nakamura, S
    Muthusamy, TS
    Bae, JH
    Cahyadi, YH
    Udayachalerm, W
    Tresukosol, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 48A - 48A