Simultaneous quantification of MTC-220 and its metabolites in beagle dog plasma by liquid chromatography-tandem mass spectrometry

被引:3
|
作者
Liu, Xin
Zhao, Manman
Mi, Jiaqi
Liu, Zhihao
Hu, Jinping
Sheng, Li
Wang, Baolian
Li, Dan
Yang, Shuang
Li, Yan [1 ]
机构
[1] Chinese Acad Med Sci, Inst Mat Med, Key Lab Act Subst Discovery & Drug Abil Evaluat, Dept Drug Metab,State Key Lab Bioact Subst & Func, Beijing 100050, Peoples R China
关键词
MTC-220; Paclitaxel; MDA-linker; LC-ESI-MS/MS; Pharmacokinetics; MURAMYL DIPEPTIDE ANALOG; METASTASIS; TAXANES; PACLITAXEL; CONJUGATE; CANCER;
D O I
10.1016/j.jpba.2014.06.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive LC-ESI-MS/MS method for simultaneous determination of MTC-220 and its metabolites (paclitaxel and MDA-linker) in dog plasma has been developed and validated. After addition of docetaxel (internal standard), plasma samples containing MTC-220, paclitaxel and MDA-linker were prepared based on a simple protein precipitation by adding two volumes of acetonitrile. The separation was performed on a ZorbaxSB-C18 column (3.5 mu m, 2.1 mm x 100 mm) at a flow rate of 0.2 ml/min, using acetonitrile/water containing 0.1% formic acid (v/v) as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) by selected reaction monitoring (SRM). The MS/MS ion transit ions monitored were 1444.4 -> 623.8 for MTC-220, 876.4 -> 307.9 for paclitaxel, 631.2 -> 531.2 for MDA-linker and 830.2 -> 549.1 for the internal standard. Linear detection responses were obtained for MTC-220, paclitaxel and MDA-linker ranging from 10 to 5000, 5 to 2500 and 5 to 500 ng/ml, respectively. The lower limits of quantitation (LLOQs) for MTC-220, paclitaxel and MDA-linker were 10, 5 and 5 ng/ml, respectively. The intra-day and inter-day precisions (RSD, %) of the three analytes do not exceed 10.9% except for LLOQs (<= 17.50), and the accuracy (RE, %) were within +/- 17.5% for LLOQs and +/- 12.6% for the others. The average recoveries of three compounds were greater than 85.0%. The analytes were proved to be stable during all sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic studies of MTC-220 and its metabolites in beagle dogs after intravenous infusion of MTC-220 at 2.5 mg/kg.. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [21] Simultaneous quantification of tegoprazan and its major metabolite M1 in dog plasma using liquid chromatography-tandem mass spectrometry
    Kim, Joohwan
    Kim, Sungjun
    Noh, Hyun-Jung
    Ryu, Shin-Young
    Kim, Soo-Jin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 171 : 99 - 103
  • [22] Liquid chromatography-tandem mass spectrometry for the quantification of ripretinib and its metabolites DP-5439 in human plasma
    Lin, Jiahui
    Jiang, Aiting
    Zheng, Juntao
    Wu, Jingjing
    Li, Hao
    Cai, Shirong
    He, Yulong
    Chen, Xiao
    Zhong, Guoping
    Tang, Ke-Jing
    Zhang, Xinhua
    Xia, Yanzhe
    FRONTIERS IN PHARMACOLOGY, 2025, 15
  • [23] Liquid chromatography-tandem mass spectrometry assay for the simultaneous quantification of simvastatin, lovastatin, atorvastatin, and their major metabolites in human plasma
    Wang, Jiang
    Luzum, Jasmine A.
    Phelps, Mitch A.
    Kitzmiller, Joseph P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 983 : 18 - 25
  • [24] Simultaneous quantification of buprenorphine, naloxone and phase I and II metabolites in plasma and breastmilk by liquid chromatography-tandem mass spectrometry
    Swortwood, Madeleine J.
    Scheidweiler, Karl B.
    Barnes, Allan J.
    Jansson, Lauren M.
    Huestis, Marilyn A.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 70 - 77
  • [25] Simultaneous determination of evodiamine and evodine in Beagle dog plasma using liquid chromatography tandem mass spectrometry
    Xia, Yuan-Yuan
    Xu, Hai-Yu
    Cai, You-You
    Si, Duan-Yun
    Liu, Chang-Xiao
    JOURNAL OF ASIAN NATURAL PRODUCTS RESEARCH, 2013, 15 (03) : 235 - 243
  • [26] Simultaneous quantification of seven plasma metabolites of sulfur mustard by ultra high performance liquid chromatography-tandem mass spectrometry
    Li, Chunzheng
    Chen, Jia
    Liu, Qin
    Xie, Jianwei
    Li, Hua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 917 : 100 - 107
  • [27] Simultaneous Determination of Ticagrelor and Its Metabolites in Human Plasma and Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    Zhong, Wanping
    Wang, Xipei
    Tang, Lan
    Mai, Liping
    Chen, Xiao-Ping
    He, Guodong
    Zheng, Zhijie
    Zhong, Shilong
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (06) : 445 - 453
  • [28] Simultaneous determination of forsythin and its major metabolites in human plasma via liquid chromatography-tandem mass spectrometry
    Pan, Lu-lu
    Chen, Tao
    Hui, Min
    Wang, Shuo
    Fu, Li
    Li, Cui-yun
    Zhang, Hong
    Ding, Yan-hua
    Yang, Yong
    Zhong, Da-fang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 198
  • [29] Simultaneous quantification of oleuropein and its metabolites in rat plasma by liquid chromatography electrospray ionization tandem mass spectrometry
    Bazoti, Fotini N.
    Gikas, Evangelos
    Tsarbopoulos, Anthony
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (05) : 506 - 515
  • [30] Identification of scopolamine and its metabolites in rat plasma by liquid chromatography-tandem mass spectrometry
    Chen Huaixia
    Du Peng
    Han Fengmei
    Chen Yong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (06) : 851 - 854