Optimization of dual-energy imaging systems using generalized NEQ and imaging task

被引:104
|
作者
Richard, S.
Siewerdsen, J. H.
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[2] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[4] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
DQE; MTF; NPS; dual-energy imaging; flat-panel detector; imaging performance; image noise; anatomical noise; cascaded systems analysis; optimization;
D O I
10.1118/1.2400620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual-energy (DE) imaging is a promising advanced application of flat-panel detectors (FPDs) with a potential host of applications ranging from thoracic and cardiac imaging to interventional procedures. The performance of FPD-based DE imaging systems is investigated in this work by incorporating the noise-power spectrum associated with overlying anatomical structures ("anatomical noise" modeled according to a I If characteristic) into descriptions of noise-equivalent quanta (NEQ) to yield the generalized NEQ (GNEQ). Signal and noise propagation in the DE imaging chain is modeled by cascaded systems analysis. A Fourier-based description of the imaging task is integrated with the GNEQ to yield a detectability index used as an objective function for optimizing DE image reconstruction, allocation of dose between low- and high-energy images, and selection of low- and hiah-kVp. Optimal reconstruction and acquisition parameters were found to depend on dose; for example, optimal kVp varied from [60/150] kVp at typical radiographic dose levels (similar to 0.5 mGy entrance surface dose, ESD) but increased to [90/150] kVp at high dose (ESD similar to 5.0 mGy). At very low dose (ESD similar to 0.05 mGy), detectability index indicates an optimal low-energy technique of 60 kVp but was largely insensitive to the choice of high-kVp in the range 120-150 kVp. Similarly, optimal dose allocation, defined as the ratio of low-energy ESD and the total ESD, varied from 0.2 to 0.4 over the range ESD=(0.05-5.0) mGy. Furthermore, two applications of the theoretical framework were explored: (i) the increase in detectability for DE imaging compared to conventional radiography; and (ii) the performance of single-shot vs double-shot DE imaging. wherein the latter is found to have a DQE approximately twice that of the former. Experimental and theoretical analysis of GNEQ,and task-based detectability index provides a fundamental understanding of the factors governing DE imaging performance and offers a framework for system design and optimization. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:127 / 139
页数:13
相关论文
共 50 条
  • [1] Task-based optimization of dual-energy imaging systems using generalized NEQ
    Richard, S
    Siewerdsen, J
    Jaffray, D
    Moseley, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2080 - 2080
  • [2] NEQ and task in dual-energy imaging: From cascaded systems analysis to human observer performance
    Richard, Samuel
    Siewerdsen, Jeffrey H.
    Tward, Daniel J.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [3] Improved Lesion Conspicuity in Dual-Energy Imaging of the Chest: From NEQ to Observer Performance
    Richard, S.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] VESSEL IMAGING USING DUAL-ENERGY TOMOSYNTHESIS
    LIU, J
    NISHIMURA, D
    MACOVSKI, A
    MEDICAL PHYSICS, 1987, 14 (06) : 950 - 955
  • [5] A Cascaded Systems Model for Imaging Performance and Task-Based Optimization in Dual-Energy Cone-Beam CT
    Gang, G.
    Prakash, P.
    Zbijewski, W.
    Stayman, J.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3833 - +
  • [6] Dual-Energy Imaging of the Pancreas
    Keraliya A.
    Uyeda J.W.
    Current Radiology Reports, 6 (12)
  • [7] Dual-Energy Imaging of the Chest
    Vulasala, Sai Swarupa R.
    Wynn, Gregory Carl
    Hernandez, Mauricio
    Kadambi, Isiri
    Gopireddy, Dheeraj Reddy
    Bhosale, Priya
    Virarkar, Mayur K.
    SEMINARS IN ULTRASOUND CT AND MRI, 2022, 43 (04) : 311 - 319
  • [8] DUAL-ENERGY MAMMOGRAPHIC IMAGING
    JOHNS, PC
    DROST, DJ
    YAFFE, MJ
    FENSTER, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (06) : 1360 - 1360
  • [9] Generalized DQE analysis of dual-energy imaging using flat-panel detectors
    Richard, S
    Siewerdsen, JH
    Jaffray, DA
    Moseley, DJ
    Bakhtiar, B
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 519 - 528
  • [10] Optimization of image acquisition techniques for dual-energy imaging of the chest
    Shkumat, N. A.
    Siewerdsen, J. H.
    Dhanantwari, A. C.
    Williams, D. B.
    Richard, S.
    Paul, N. S.
    Yorkston, J.
    Van Metter, R.
    MEDICAL PHYSICS, 2007, 34 (10) : 3904 - 3915