Piezoresistive micromechanical transducer operation in a pulsed neutron and gamma ray environment

被引:0
|
作者
McCready, SS [1 ]
Harlow, TH [1 ]
Heger, AS [1 ]
Holbert, KE [1 ]
机构
[1] Los Alamos Natl Lab, WR, ESA, Los Alamos, NM 87545 USA
关键词
piezoresistive; transducer; accelerometer; pressure; temperature; microelectromechanical; MEMS; radiation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We completed the third in a series of experiments using commercially available, piezoresistive microelectromechanical system (MEMS) transducers to instrument articles exposed to the intense, pulsed neutron and gamma ray radiation environment of Sandia National Laboratories' Annular Core Research Reactor. Based on analyzing the survival of pressure transducers and accelerometers in the first two experiments, we identified candidate piezoresistive, MEMS transducers and then tested them by exposure to pulses, each with 10(15) neutrons/cm' and 10(4) Gy (1 Mrad) of gamma radiation. Simultaneous measurement of temperature indicates that the pressure transducers retain their calibrations and may provide a means of quickly identifying temperature-induced offset shifts of accelerometer calibrations. Comparison to other sensors that do not survive in this environment and implications for using these transducers to instrument test articles are also presented.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [21] PULSED GAMMA-RAY LASER
    TRAMMELL, GT
    HANNON, JP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 637 - 637
  • [22] Neutron and gamma-ray measurements
    Krasilnikov, Anatoly V.
    Sasao, Mamiko
    Kaschuck, Yuri A.
    Kiptily, Vasily G.
    Nishitani, Takeo
    Popovichev, Sergey V.
    Bertalot, Luciano
    BURNING PLASMA DIAGNOSTICS, 2008, 988 : 249 - +
  • [23] NEUTRON AND GAMMA-RAY TRANSPORT
    PODGOR, S
    HERLING, GH
    REPORT OF NRL PROGRESS, 1974, (AUG): : 33 - 34
  • [24] A COMBINATION NEUTRON AND GAMMA RAY SPECTROMETER
    CIALELLA, CM
    DEVANNEY, JA
    NUCLEAR INSTRUMENTS & METHODS, 1968, 60 (03): : 269 - +
  • [25] Boron shielding design for neutron and gamma detectors of a pulsed neutron tool
    Wang, Xin-Yang
    Chen, Jun-Yan
    Zhang, Qiong
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (01)
  • [26] Boron shielding design for neutron and gamma detectors of a pulsed neutron tool
    Xin-Yang Wang
    Jun-Yan Chen
    Qiong Zhang
    Nuclear Science and Techniques, 2025, 36 (01) : 188 - 199
  • [27] PULSED NEUTRON EXPERIMENT WITH BERYLLIUM BY USE OF A GAMMA-RAY FLASH FROM AN ELECTRON LINEAR ACCELERATOR
    AIZAWA, O
    KADOTANI, H
    KANDA, K
    FUJITA, Y
    ITO, S
    NUCLEAR SCIENCE AND ENGINEERING, 1973, 50 (01) : 38 - 45
  • [28] Numerical simulation of pulsed neutron source density logging's secondary captured gamma ray strength
    Pan, Baozhi
    Zhang, Rui
    Liu, Kun
    Li, Ding
    Jiang, Bici
    Geophysical Prospecting for Petroleum, 2014, 53 (06) : 642 - 648
  • [29] On the origin of sub-TeV gamma-ray pulsed emission from rotating neutron stars
    Bednarek, W.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2012, 424 (03) : 2079 - 2085
  • [30] Numerical simulation on pulsed neutron-gamma ray density logging response in logging while drilling
    Zhang, Feng
    Yuan, Chao
    Liu, Jun-Tao
    Jia, Yan
    Diqiu Kexue - Zhongguo Dizhi Daxue Xuebao/Earth Science - Journal of China University of Geosciences, 2013, 38 (05): : 1116 - 1120